Volvo/Mack · MID 128 engine ECU - air, turbo, EGR and brake

Volvo/Mack Variable geometry turbo actuator fault codes

On engines with a variable geometry turbocharger an electronic actuator moves the vanes on command from the engine ECU. These codes cover its communication, circuit, calibration and mechanical movement.

FaultCheckMID 128SID 27FMI 2Volvo/Mack · Variable geometry turbo actuator
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect the Premium Tech Tool or a J1939/J1587 scan tool to the diagnostic socket and read the codes for every module, not only the engine.

What do these codes mean?

Volvo/Mack codes MID 128 SID 27 FMI 2 to MID 128 SID 27 FMI 13 are all about the variable geometry turbo actuator. The most common failure type is part or controller (2 of 5); 1 needs an immediate stop. Start with this check: inspect the actuator connector and harness for burn marks, rubbing and corrosion.

How urgent are they?

1 of 5 codes here means stop now; the other 4 can wait until the shift ends, but find the cause before the next one.

  • Stop now1
  • Check soon4

What should I check first?

Inspect the actuator connector and harness for burn marks, rubbing and corrosion

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Volvo/Mack MID 128 SID 27 FMI 2Variable geometry turbo actuator - No valid command received

    The variable geometry turbocharger (VGT) smart actuator has not seen a valid command on the CAN 2 data link, so it cannot position the nozzle as the ECM asks.· Erratic or implausible
    Check soon

    Causes

    • Damaged CAN 2 harness or connector to the VGT actuator
    • No supply or ground at the VGT actuator
    • VGT smart remote actuator failed
    • Engine ECM not sending the command

    Checks

    1. 1Read the VGT actuator status and position in the scan tool; no response points at the data link or power
    2. 2Check the actuator connector for water, corrosion and melted pins near the exhaust
    3. 3Measure supply voltage and ground at the actuator plug with the key on
    4. 4Check the CAN 2 pair for continuity and shorts
    5. 5Replace the actuator only after power and data link are proven
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Volvo/Mack MID 128 SID 27 FMI 4Variable geometry turbo actuator shorted to ground

    The VGT actuator circuit is shorted to ground.· Shorted low
    Check soon

    Causes

    • Actuator wiring shorted to ground
    • Faulty VGT actuator
    • Damaged actuator connector

    Checks

    1. 1Check the actuator connector for damage and moisture near the turbo
    2. 2Test the actuator wires for a short to ground with the key off
    3. 3Check the supply and data signal at the actuator plug
    4. 4Replace the actuator if the harness is good and confirm the code does not return
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Volvo/Mack MID 128 SID 27 FMI 7Variable geometry turbo actuator mechanical fault

    Mack lists a mechanical problem with the VGT actuator or nozzle.· Part or controller
    Check soon

    Causes

    • Sticking or carboned-up VGT nozzle
    • Mechanical failure inside the actuator
    • Linkage binding

    Checks

    1. 1Command the VGT through its range in the scan tool and watch if position follows
    2. 2Compare actual boost with the commanded boost under load
    3. 3Inspect the turbo for soot build-up or exhaust leaks
    4. 4Replace the actuator or turbo according to the test results
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Volvo/Mack MID 128 SID 27 FMI 9Variable geometry turbo actuator data missing for 2 seconds

    Data from the VGT actuator has been missing for two seconds.· Lost message
    Stop now

    Causes

    • Data link harness fault to the VGT actuator
    • No supply to the VGT actuator
    • VGT actuator failure

    Checks

    1. 1Check the actuator supply voltage and ground at its plug
    2. 2Inspect the data link connector at the actuator for water and heat damage
    3. 3Check the CAN 2 pair for shorts or opens for damage, corrosion or looseness
    4. 4Replace the actuator if the supply and data link are good
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Volvo/Mack MID 128 SID 27 FMI 13Variable geometry turbo actuator self-calibration failed

    The variable geometry turbo actuator failed its self-calibration, so the ECM does not know the nozzle end positions and cannot position it accurately.· Part or controller
    Check soon

    Causes

    • VGT actuator failed
    • Nozzle sticking at an end stop
    • Supply voltage dropping during calibration

    Checks

    1. 1Check battery voltage and ground connections before repeating the calibration
    2. 2Cycle the key and watch the calibration run in the scan tool
    3. 3Inspect the turbo for carbon build-up and a sticking nozzle
    4. 4Replace the actuator if calibration fails again
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

Shared checks

Checks, in order

  1. 1Inspect the actuator connector and harness for burn marks, rubbing and corrosion
  2. 2Command the actuator with the scan tool and watch whether the vane position follows
  3. 3Check the turbo linkage for free movement with the engine cold and off
  4. 4Run the actuator calibration routine after any repair and clear the codes

Causes

  • Actuator failed internally or its calibration was lost
  • Vane mechanism sticking from soot and carbon
  • Damaged actuator harness or poor connector contact

Most common here: part or controller (2 of 5)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: The engine loses power, boost is wrong, and a stop or check lamp may come on, with a derate on the more severe codes.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.