EF Logo

Cummins · Air handling

Cummins Intake manifold pressure and temperature sensors fault codes

The intake manifold pressure sensor (a boost sensor) tells the ECM how much boost the turbocharger is making, and the intake manifold temperature sensor (a thermistor) reports the charge-air temperature after the cooler. They sit in or beside the manifold, often in one housing, and the ECM uses both to set fuelling, EGR flow, turbo vane position and cold-start behaviour.

FaultCheck122Cummins · Intake manifold pressure and temperature sensors
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 122 to 7583 are all about the intake manifold pressure and temperature sensors. The most common failure type is real condition (9 of 23); 3 need an immediate stop. Start with this check: read boost pressure and intake manifold temperature at key on, engine off: boost should equal barometric pressure and temperature should match ambient on a cold engine.

How urgent are they?

3 of 23 codes here mean stop now; 15 can wait until the shift ends, but find the cause before the next one; 5 are information only.

  • Stop now3
  • Check soon15
  • Info5

What should I check first?

Read boost pressure and intake manifold temperature at key on, engine off: boost should equal barometric pressure and temperature should match ambient on a cold engine

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Intake manifold 1 temperature5 codes

    • Cummins 155Intake manifold 1 temperature: Above normal· most severe

      The intake manifold 1 temperature is above its normal operating range and the ECM rates it as most severe.· Real condition
      Stop now

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 temperature with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 temperature - above normal - most severe

    • Cummins 436Intake manifold 1 temperature: Erratic reading

      The ECM judges the intake manifold 1 temperature to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the intake manifold 1 temperature live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake manifold 1 temperature - data erratic or incorrect

    • Cummins 488Intake manifold 1 temperature: Above normal· moderately severe

      The intake manifold 1 temperature is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 temperature with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 temperature - above normal - moderately severe

    • Cummins 1848Intake manifold 1 temperature: Abnormal rate of change

      The intake manifold 1 temperature reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the intake manifold 1 temperature reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3385Intake manifold 1 temperature: Below normal· moderately severe

      The intake manifold 1 temperature is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 temperature with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 temperature - below normal - moderately severe

  • Intake manifold 1 pressure sensor1 code

    • Cummins 2191Intake manifold 1 pressure sensor: Condition exists

      The ECM sets this code when it recognises a defined condition for the intake manifold 1 pressure sensor.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Intake manifold 1 pressure8 codes

    • Cummins 3361Intake manifold 1 pressure: Abnormal rate of change

      The intake manifold 1 pressure reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the intake manifold 1 pressure reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4616Intake manifold 1 pressure: Below normal· least severe

      The intake manifold 1 pressure is below its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 pressure - below normal - least severe

    • Cummins 4729Intake manifold 1 pressure: Below normal· most severe

      The intake manifold 1 pressure is below its normal operating range and the ECM rates it as most severe.· Real condition
      Stop now

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 pressure - below normal - most severe

    • Cummins 5989Intake manifold 1 pressure: Reading drifted high

      The intake manifold 1 pressure reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the intake manifold 1 pressure with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake manifold 1 pressure - data drifted high

    • Cummins 5991Intake manifold 1 pressure: Reading drifted low

      The intake manifold 1 pressure reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the intake manifold 1 pressure with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake manifold 1 pressure - data drifted low

    • Cummins 6725Intake manifold 1 pressure: Above normal· least severe

      The intake manifold 1 pressure is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 pressure - above normal - least severe

    • Cummins 6864Intake manifold 1 pressure: Below normal· least severe

      The intake manifold 1 pressure is below its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 pressure - below normal - least severe

    • Cummins 7583Intake manifold 1 pressure: Above normal· least severe

      The intake manifold 1 pressure is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake manifold 1 pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake manifold 1 pressure - above normal - least severe

  • Engine intake manifold pressure1 code

    • Cummins 7233Engine intake manifold pressure: Below normal· most severe

      The engine intake manifold pressure is below its normal operating range and the ECM rates it as most severe.· Real condition
      Stop now

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live engine intake manifold pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine intake manifold pressure - below normal - most severe

  • Other codes8 codes

    • Cummins 122Intake manifold pressure sensor signal voltage high

      The ECM sees the intake manifold pressure sensor signal above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Sensor signal wire rubbed through against the intake manifold bracket and touching the 5 V reference
      • Open return wire between the boost sensor and the ECM, so the signal climbs to reference
      • Pressure sensor failed high internally after oil or moisture got into the port
      • Connector shared by the intake temperature element corroded, lifting the signal

      Checks

      1. 1Key on, engine off: manifold pressure should match barometric pressure; a reading near the top of its scale confirms a high-voltage fault
      2. 2Unplug the boost sensor and read the three pins at the harness; 5 V reference and a good return must both be present
      3. 3Probe the signal pin to the reference pin and to battery positive with the key off to find a short in the harness
      4. 4Check the return wire resistance from the sensor connector to the ECM pin; a high reading means a bad splice or terminal
      5. 5Fit a known-good sensor only after the harness tests clean and the port is open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 123Intake manifold pressure sensor signal voltage low

      The ECM sees the intake manifold pressure sensor signal below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire chafed to the cylinder head or intake bracket and shorted to ground
      • 5 V reference wire open in the harness, so the sensor is not powered
      • Pressure sensor failed low after an internal short
      • Sensor connector pushed on crooked, leaving the reference pin out of contact

      Checks

      1. 1Key on, engine off: a manifold reading far below barometric pressure points at a lost supply or a short to ground
      2. 2Measure 5 V between the reference and return pins at the unplugged sensor connector
      3. 3Ohm the signal wire to engine ground with the ECM connector unplugged; it must read open
      4. 4Swap the sensor connector for a bench jumper from a known-good sensor to see whether the reading recovers
      5. 5Replace the sensor only after the reference and signal wires pass
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 124Intake manifold pressure high· moderately severe

      Boost pressure is higher than the ECM asked for.· Other
      Check soon

      Causes

      • Variable geometry turbo vanes stuck closed or the actuator sticking
      • Intake manifold pressure sensor reading high
      • Wastegate or actuator problem on turbos that have one

      Checks

      1. 1Read boost pressure and commanded boost in INSITE and see whether boost overshoots under load
      2. 2Test the VGT actuator movement in INSITE and watch whether the vanes move smoothly
      3. 3Check the intake manifold pressure sensor and its port
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:Intake manifold pressure high - moderately severe

    • Cummins 125Intake manifold pressure low· moderately severe

      Boost pressure is lower than the ECM wants at that speed and load.· Other
      Check soon

      Causes

      • Leaking charge-air pipe, clamp or cooler
      • Plugged air filter
      • Turbo vanes stuck open or turbo worn

      Checks

      1. 1Check the air filter restriction gauge or the filter condition because a blocked filter limits boost
      2. 2Inspect all intake pipes and clamps for leaks and oil
      3. 3Pressure-test the charge-air cooler for leaks, which cause low boost
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:Intake manifold pressure low - moderately severe

    • Cummins 153Intake manifold temperature sensor signal voltage high

      The ECM sees the intake manifold temperature sensor signal as very cold or open.· Shorted high
      Check soon

      Causes

      • Intake temperature element in the manifold open after an overheat
      • Wire broken where it flexes at the intake manifold
      • Connector pulled loose by the charge-air hose

      Checks

      1. 1Cold start: the reading should sit near ambient; a very cold or stuck-at-minimum value means open
      2. 2Bridge the two harness pins with the sensor unplugged and watch the reading swing to hot
      3. 3Check continuity of both intake temperature wires from the sensor plug to the ECM connector with the key off
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 154Intake manifold temperature sensor signal voltage low

      The ECM sees the intake manifold temperature sensor signal as extremely hot or shorted.· Shorted low
      Check soon

      Causes

      • Intake temperature wire chafed against the manifold and grounded
      • Oil from the charge-air cooler bridging the connector terminals
      • Element in the sensor shorted

      Checks

      1. 1Cold start: a very hot intake reading shows a short
      2. 2Unplug the sensor and see whether the value swings cold
      3. 3Measure signal to ground at the harness with the key off
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 2964Intake manifold temperature high· least severe

      The charge air in the intake manifold is hotter than expected.· Other
      Check soon

      Causes

      • Charge-air cooler blocked on the outside with dirt or on the inside with oil
      • Charge-air leak or hose collapsing
      • Cooling fan not running

      Checks

      1. 1Check the charge-air cooler fins and the airflow
      2. 2Check the charge-air hoses and clamps for leaks, since a leak lets hot air enter the intake
      3. 3Check the cooling fan engages and the shroud is in place so air flows through the cooler
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:Intake manifold temperature high - least severe

    • Cummins 2973Intake manifold pressure sensor data erratic or implausible

      The ECM does not trust the intake manifold pressure sensor reading because it drifts, jumps or disagrees with other sensors.· Erratic or implausible
      Check soon

      Causes

      • Boost leak after the charge-air cooler making the manifold pressure disagree with demand
      • Boost sensor port blocked with soot or oil so the sensor reads a stale value
      • Turbo actuator sticking, so real boost is wrong while the sensor is right
      • Connector pin making contact only part of the time

      Checks

      1. 1Compare manifold pressure with barometric pressure at key on and with the engine running at idle
      2. 2Check the charge-air pipes and clamps for leaks and oil film
      3. 3Remove the boost sensor and look into its port for soot and oil that would hold a stale reading
      4. 4Wiggle the harness while watching the live value
      5. 5Check the VGT movement in INSITE before replacing the sensor
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

Shared checks

Checks, in order

  1. 1Read boost pressure and intake manifold temperature at key on, engine off: boost should equal barometric pressure and temperature should match ambient on a cold engine
  2. 2Unplug the sensor and check reference, return and signal at the ECM side for the correct 5 V and ground
  3. 3Inspect the connector for oil, water and bent pins, and wiggle the harness while watching the live value
  4. 4Check the charge-air piping, clamps and cooler for leaks or blockage before blaming the sensor
  5. 5Compare the reading against a known good sensor or a calibrated gauge at the same engine load
  6. 6Clear the codes and road test under load to see which sensor reading is wrong again

Causes

  • Connector or harness damage at the manifold, where heat and vibration are highest
  • Sensor port or sensing passage clogged with oil or soot
  • Real boost leak, restricted charge-air cooler or turbo fault that makes the reading genuine
  • Failed pressure element or thermistor

Most common here: real condition (9 of 23)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: Low power, black or white smoke, slow boost build-up and a possible derate, with the engine otherwise running; a temperature fault can also change cold-start behaviour.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.