Cummins · Air handling
Cummins Crankcase, intake throttle and air shutoff fault codes
A sensor on the crankcase breather system measures how much pressure builds in the crankcase, which tells the ECM whether the breather or filter is plugged or the engine has excessive blow-by. A heater in the closed crankcase ventilation filter keeps condensate from freezing in cold weather.
More about these partsLess
An electronic throttle in the intake path restricts air for regeneration control and EGR flow. An air shutoff valve in the intake can close to stop an overspeeding engine. These are monitor results rather than single-component faults.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 175 to 6337 are all about the crankcase, intake throttle and air shutoff. The most common failure type is shorted high (7 of 27); 1 needs an immediate stop. Start with this check: check the crankcase breather filter is not saturated or plugged and replace it at the interval.
How urgent are they?
1 of 27 codes here means stop now; 23 can wait until the shift ends, but find the cause before the next one; 3 are information only.
- Stop now1
- Check soon23
- Info3
What should I check first?
Check the crankcase breather filter is not saturated or plugged and replace it at the interval
Shared checks27 of 27
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Electronic throttle control actuator driver circuit4 codes
Cummins 175Electronic throttle control actuator driver circuit: Voltage high / shorted high
Same failure as 1843 on the electronic throttle control actuator driver circuit: the same fault condition as 1843, reported for this part. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the electronic throttle control actuator driver circuit
- Wiring or connector problem local to the electronic throttle control actuator driver circuit
Checks
- 1Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
- 2Work through the checks listed for 1843, starting at the electronic throttle control actuator driver circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Electronic throttle control actuator driver circuit - voltage high (shorted to a high source)
Cummins 176Electronic throttle control actuator driver circuit: Voltage low / shorted low
Same failure as 1844 on the electronic throttle control actuator driver circuit: the same fault condition as 1844, reported for this part. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the electronic throttle control actuator driver circuit
- Wiring or connector problem local to the electronic throttle control actuator driver circuit
Checks
- 1Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
- 2Work through the checks listed for 1844, starting at the electronic throttle control actuator driver circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Electronic throttle control actuator driver circuit - voltage low (shorted to a low source)
Cummins 5879Electronic throttle control actuator driver circuit: Voltage high / shorted high
Same failure as 1843 on the electronic throttle control actuator driver circuit: the same fault condition as 1843, reported for this part. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the electronic throttle control actuator driver circuit
- Wiring or connector problem local to the electronic throttle control actuator driver circuit
Checks
- 1Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
- 2Work through the checks listed for 1843, starting at the electronic throttle control actuator driver circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Electronic throttle control actuator driver circuit - voltage high (shorted to a high source)
Cummins 5881Electronic throttle control actuator driver circuit: Voltage low / shorted low
Same failure as 1844 on the electronic throttle control actuator driver circuit: the same fault condition as 1844, reported for this part. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the electronic throttle control actuator driver circuit
- Wiring or connector problem local to the electronic throttle control actuator driver circuit
Checks
- 1Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
- 2Work through the checks listed for 1844, starting at the electronic throttle control actuator driver circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Electronic throttle control actuator driver circuit - voltage low (shorted to a low source)
Electronic throttle control actuator2 codes
Cummins 177Electronic throttle control actuator: Mechanical fault or not responding
The ECM commands the electronic throttle control actuator but sees no matching response, so it reports a mechanical fault or a part that is not responding even though the wiring may be fine. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Part or controllerPart or controllerCheck soonCauses
- Electronic throttle control actuator stuck, seized or restricted by dirt, soot or wear
- Electrical supply too weak to move the part
- Mechanical linkage or return spring broken
Checks
- 1Command the electronic throttle control actuator with the service tool and watch or listen for it to move
- 2Remove the electronic throttle control actuator and inspect it for sticking, wear, carbon or debris
- 3Check supply voltage and ground at the electronic throttle control actuator while it is commanded
- 4Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 5882Electronic throttle control actuator: Mechanical fault or not responding
Same failure as 177 on the electronic throttle control actuator: the same fault condition as 177, reported for this part. The electronic throttle control actuator is the motor that moves the intake throttle plate under ECM command.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 177, applied to the electronic throttle control actuator
- Wiring or connector problem local to the electronic throttle control actuator
Checks
- 1Check the throttle plate for carbon build-up and free movement by hand with the actuator unplugged.
- 2Work through the checks listed for 177, starting at the electronic throttle control actuator and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Crankcase pressure4 codes
Cummins 555Crankcase pressure: Above normal· moderately severe
Same failure as 556 on the crankcase pressure: the same fault condition as 556, reported for this part. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Real conditionReal conditionCheck soonCauses
- Same causes as 556, applied to the crankcase pressure
- Wiring or connector problem local to the crankcase pressure
Checks
- 1Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
- 2Work through the checks listed for 556, starting at the crankcase pressure and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Crankcase pressure - above normal - moderately severe
Cummins 556Crankcase pressure: Above normal· most severe
The crankcase pressure is above its normal range (severity: most severe). The ECM sets the code from a real reading, so look for a genuine cause before blaming the sensor. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Real conditionReal conditionStop nowCauses
- A real over-limit condition in the system the crankcase pressure measures
- Sensor or circuit reading high from a wiring fault
- A cooling, flow or restriction problem upstream that drives the value up
Checks
- 1Confirm the real condition with a gauge or a second reading before replacing the crankcase pressure
- 2Check that the crankcase pressure circuit codes are not active, since a wiring fault can fake a high reading
- 3Look for the physical cause upstream, such as restriction, leakage, poor cooling or heavy load
- 4Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Crankcase pressure - above normal - most severe
Cummins 1942Crankcase pressure: Erratic reading
The ECM judges the crankcase pressure to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact on the crankcase pressure
- Part ageing or failing and giving unstable output
- Electrical noise from a poorly routed wire or a bad ground
Checks
- 1Watch the crankcase pressure live in INSITE and wiggle the harness and connector to catch dropouts
- 2Compare the crankcase pressure with a related reading to decide which one is wrong
- 3Check the connector for moisture and corrosion and the ground connection for tightness
- 4Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Crankcase pressure - data erratic or incorrect
Cummins 1974Crankcase pressure: Above normal· moderately severe
Same failure as 556 on the crankcase pressure: the same fault condition as 556, reported for this part. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Real conditionReal conditionCheck soonCauses
- Same causes as 556, applied to the crankcase pressure
- Wiring or connector problem local to the crankcase pressure
Checks
- 1Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
- 2Work through the checks listed for 556, starting at the crankcase pressure and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Crankcase pressure - above normal - moderately severe
Crankcase pressure circuit2 codes
Cummins 1843Crankcase pressure circuit: Voltage high / shorted high
The ECM reads the crankcase pressure circuit above its allowed voltage band. That points to a short to a 5 V or battery wire, a lost return, or a failed part, rather than a real change in what it measures. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Shorted highShorted highCheck soonCauses
- Short to a 5 V reference or a battery wire in the harness to the crankcase pressure circuit
- Open or high-resistance return wire that lets the signal float high
- Water or corrosion in the connector bridging two pins together
Checks
- 1Key on, unplug the crankcase pressure circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
- 2Jumper the signal wire of the crankcase pressure circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
- 3Check continuity and resistance of the return wire from the crankcase pressure circuit back to the ECM
- 4Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Crankcase pressure circuit - voltage high (shorted to a high source)
Cummins 1844Crankcase pressure circuit: Voltage low / shorted low
The ECM reads the crankcase pressure circuit below its allowed voltage band. That points to a short to ground, an open supply or signal wire, or a failed part, not necessarily a real low value. The crankcase pressure sensor watches blow-by, so a real high reading also points at worn rings, a plugged breather or a failed breather filter.· Shorted lowShorted lowCheck soonCauses
- Signal wire to the crankcase pressure circuit rubbed through and shorted to ground or to the engine block
- Open 5 V reference or open signal wire that lets the input drop to zero
- Corroded or backed-out pin in the crankcase pressure circuit connector
Checks
- 1Key on, unplug the crankcase pressure circuit and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
- 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
- 3Measure resistance from the crankcase pressure circuit signal wire to ground with the ECM unplugged to find a short
- 4Check the crankcase breather filter service condition and the blow-by before condemning the pressure sensor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Crankcase pressure circuit - voltage low (shorted to a low source)
Engine air shutoff circuit3 codes
Cummins 3139Engine air shutoff circuit: Voltage high / shorted high
Same failure as 1843 on the engine air shutoff circuit: the same fault condition as 1843, reported for this part. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the engine air shutoff circuit
- Wiring or connector problem local to the engine air shutoff circuit
Checks
- 1Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
- 2Work through the checks listed for 1843, starting at the engine air shutoff circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine air shutoff circuit - voltage high (shorted to a high source)
Cummins 3141Engine air shutoff circuit: Voltage low / shorted low
Same failure as 1844 on the engine air shutoff circuit: the same fault condition as 1844, reported for this part. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the engine air shutoff circuit
- Wiring or connector problem local to the engine air shutoff circuit
Checks
- 1Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
- 2Work through the checks listed for 1844, starting at the engine air shutoff circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine air shutoff circuit - voltage low (shorted to a low source)
Cummins 4484Engine air shutoff circuit: Mechanical fault or not responding
Same failure as 177 on the engine air shutoff circuit: the same fault condition as 177, reported for this part. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 177, applied to the engine air shutoff circuit
- Wiring or connector problem local to the engine air shutoff circuit
Checks
- 1Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
- 2Work through the checks listed for 177, starting at the engine air shutoff circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Engine charge-air cooler efficiency1 code
Cummins 3343Engine charge-air cooler efficiency: Below normal· moderately severe
The engine charge-air cooler efficiency is below its normal range (severity: moderately severe). The ECM sets the code from a real reading, so look for a genuine cause before blaming the sensor. Charge-air cooler efficiency is calculated from the intake temperatures, so a leaking or fouled cooler shows up here first.· Real conditionReal conditionCheck soonCauses
- A real shortfall in the system the engine charge-air cooler efficiency measures
- Sensor or circuit reading low from a wiring fault
- A leak, low level or weak supply that lets the value fall
Checks
- 1Confirm the real condition with a gauge or a second reading before replacing the engine charge-air cooler efficiency
- 2Check that the engine charge-air cooler efficiency circuit codes are not active, since a wiring fault can fake a low reading
- 3Look for the physical cause upstream, such as a leak, low fluid, weak pump or blocked supply
- 4Pressure test the charge-air cooler and look for oil, debris or bent fins that reduce airflow.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine charge-air cooler efficiency - below normal - moderately severe
Engine intake throttle actuator position sensor circuit2 codes
Cummins 3539Engine intake throttle actuator position sensor circuit: Voltage high / shorted high
Same failure as 1843 on the engine intake throttle actuator position sensor circuit: the same fault condition as 1843, reported for this part. The intake throttle actuator has its own position sensor, which tells the ECM how far the throttle plate has actually opened.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the engine intake throttle actuator position sensor circuit
- Wiring or connector problem local to the engine intake throttle actuator position sensor circuit
Checks
- 1Command the intake throttle through its range and watch the position value follow it smoothly.
- 2Work through the checks listed for 1843, starting at the engine intake throttle actuator position sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine intake throttle actuator position sensor circuit - voltage high (shorted to a high source)
Cummins 3541Engine intake throttle actuator position sensor circuit: Voltage low / shorted low
Same failure as 1844 on the engine intake throttle actuator position sensor circuit: the same fault condition as 1844, reported for this part. The intake throttle actuator has its own position sensor, which tells the ECM how far the throttle plate has actually opened.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the engine intake throttle actuator position sensor circuit
- Wiring or connector problem local to the engine intake throttle actuator position sensor circuit
Checks
- 1Command the intake throttle through its range and watch the position value follow it smoothly.
- 2Work through the checks listed for 1844, starting at the engine intake throttle actuator position sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine intake throttle actuator position sensor circuit - voltage low (shorted to a low source)
Engine intake throttle actuator position sensor1 code
Cummins 3542Engine intake throttle actuator position sensor: Erratic reading
Same failure as 1942 on the engine intake throttle actuator position sensor: the same fault condition as 1942, reported for this part. The intake throttle actuator has its own position sensor, which tells the ECM how far the throttle plate has actually opened.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 1942, applied to the engine intake throttle actuator position sensor
- Wiring or connector problem local to the engine intake throttle actuator position sensor
Checks
- 1Command the intake throttle through its range and watch the position value follow it smoothly.
- 2Work through the checks listed for 1942, starting at the engine intake throttle actuator position sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine intake throttle actuator position sensor - data erratic or incorrect
Crankcase breather filter heater circuit4 codes
Cummins 3733Crankcase breather filter heater circuit: Voltage high / shorted high
Same failure as 1843 on the crankcase breather filter heater circuit: the same fault condition as 1843, reported for this part. The breather filter heater keeps the separator from freezing and waxing up in cold weather, so the fault matters mostly at low temperature.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the crankcase breather filter heater circuit
- Wiring or connector problem local to the crankcase breather filter heater circuit
Checks
- 1Measure the heater element resistance and check its relay or driver output with the ambient cold.
- 2Work through the checks listed for 1843, starting at the crankcase breather filter heater circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Crankcase breather filter heater circuit - voltage high (shorted to a high source)
Cummins 3734Crankcase breather filter heater circuit: Voltage low / shorted low
Same failure as 1844 on the crankcase breather filter heater circuit: the same fault condition as 1844, reported for this part. The breather filter heater keeps the separator from freezing and waxing up in cold weather, so the fault matters mostly at low temperature.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the crankcase breather filter heater circuit
- Wiring or connector problem local to the crankcase breather filter heater circuit
Checks
- 1Measure the heater element resistance and check its relay or driver output with the ambient cold.
- 2Work through the checks listed for 1844, starting at the crankcase breather filter heater circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Crankcase breather filter heater circuit - voltage low (shorted to a low source)
Cummins 6336Crankcase breather filter heater circuit: Voltage high / shorted high
Same failure as 1843 on the crankcase breather filter heater circuit: the same fault condition as 1843, reported for this part. The breather filter heater keeps the separator from freezing and waxing up in cold weather, so the fault matters mostly at low temperature.· Shorted highShorted highCheck soonCauses
- Same causes as 1843, applied to the crankcase breather filter heater circuit
- Wiring or connector problem local to the crankcase breather filter heater circuit
Checks
- 1Measure the heater element resistance and check its relay or driver output with the ambient cold.
- 2Work through the checks listed for 1843, starting at the crankcase breather filter heater circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Crankcase breather filter heater circuit - voltage high (shorted to a high source)
Cummins 6337Crankcase breather filter heater circuit: Voltage low / shorted low
Same failure as 1844 on the crankcase breather filter heater circuit: the same fault condition as 1844, reported for this part. The breather filter heater keeps the separator from freezing and waxing up in cold weather, so the fault matters mostly at low temperature.· Shorted lowShorted lowCheck soonCauses
- Same causes as 1844, applied to the crankcase breather filter heater circuit
- Wiring or connector problem local to the crankcase breather filter heater circuit
Checks
- 1Measure the heater element resistance and check its relay or driver output with the ambient cold.
- 2Work through the checks listed for 1844, starting at the crankcase breather filter heater circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Crankcase breather filter heater circuit - voltage low (shorted to a low source)
Engine intake manifold pressure system monitor1 code
Cummins 4612Engine intake manifold pressure system monitor: Condition exists
Same failure as 4839 on the engine intake manifold pressure system monitor: the same fault condition as 4839, reported for this part. The monitor compares measured boost with what the engine should be making, so low boost from a leak or turbo fault sets it.· OtherOtherInfoCauses
- Same causes as 4839, applied to the engine intake manifold pressure system monitor
- Wiring or connector problem local to the engine intake manifold pressure system monitor
Checks
- 1Smoke test or pressure test the intake piping between the turbo and the manifold for leaks.
- 2Work through the checks listed for 4839, starting at the engine intake manifold pressure system monitor and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Engine air shutoff1 code
Cummins 4839Engine air shutoff: Condition exists
The ECM has flagged a condition on the engine air shutoff. This is a status or result code that reports a state the control strategy found, rather than a failed wire. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Real conditionReal conditionInfoCauses
- The underlying system problem that the ECM is reporting on the engine air shutoff
- A related sensor or circuit fault that triggered this condition
- Operating conditions outside what the strategy expects
Checks
- 1Read all active and inactive codes and work the circuit or sensor codes for the engine air shutoff first
- 2Check the live data around the engine air shutoff while reproducing the operating condition
- 3Inspect the system the engine air shutoff belongs to for leaks, blockage or damage
- 4Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Engine air shutoff status2 codes
Cummins 5221Engine air shutoff status: Erratic reading
Same failure as 1942 on the engine air shutoff status: the same fault condition as 1942, reported for this part. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 1942, applied to the engine air shutoff status
- Wiring or connector problem local to the engine air shutoff status
Checks
- 1Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
- 2Work through the checks listed for 1942, starting at the engine air shutoff status and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine air shutoff status - data erratic or incorrect
Cummins 5259Engine air shutoff status: Special instructions
The ECM reports a special-instruction fault on the engine air shutoff status. The cause is given in the service manual procedure for this code rather than by a standard circuit test. The engine air shutoff is an emergency valve that closes the intake to stop an overspeeding engine, so it must be reset and tested with care.· Real conditionReal conditionInfoCauses
- Condition described by the manufacturer procedure for this code
- Related data link or module fault
- Configuration or software mismatch
Checks
- 1Follow the manufacturer troubleshooting procedure for this code step by step
- 2Check the engine air shutoff status wiring, connectors and related module for faults
- 3Check the module software and configuration if the procedure points to a mismatch
- 4Check the air shutoff valve for a latched or stuck-closed state and reset it before testing the circuit.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Shared checks
Checks, in order
- 1Check the crankcase breather filter is not saturated or plugged and replace it at the interval
- 2Measure the heater resistance at its connector and compare with the wiring diagram
- 3Run the intake throttle test and see whether the plate moves smoothly through its range
- 4Check that the valve is fully open and can be reset by hand
- 5Pressure-test the charge-air system for leaks and inspect the cooler fins for debris
- 6Measure crankcase pressure with a gauge to see whether the sensor reading is real
- 7Check the relay and fuse supplying the heater
Causes
- Plugged crankcase ventilation filter or breather
- Open or shorted heater element
- Carbon sticking the throttle plate
- Valve stuck or held mechanically
Most common here: shorted high (7 of 27)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: The ECM may derate to protect the engine, and oil can leak past seals if the pressure is genuinely high.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.