Bobcat · Safety interlocks

Bobcat Traction lock and hydraulic lock solenoids fault codes

The traction lock solenoid has a pull coil that moves the lock and a hold coil that keeps it, and the hydraulic lock valve solenoid blocks the lift and tilt spools. Together they stop the machine moving or working the loader until the operator is seated and the seat bar is down.

FaultCheck15-03Bobcat · Traction lock and hydraulic lock solenoids
Code shows hereFAULT15-03

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 15-02 to M2503 are all about the traction lock and hydraulic lock solenoids. The most common failure type is open circuit (6 of 25); none needs an immediate stop. Start with this check: lower the seat bar and listen for the solenoid click; no click with voltage at the plug shows a failed coil.

How urgent are they?

None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.

  • Check soon25

What should I check first?

Lower the seat bar and listen for the solenoid click; no click with voltage at the plug shows a failed coil.

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 15-02Traction lock pull solenoid error ON

    The controller sees the traction lock pull solenoid energised when it has commanded it off.· Other
    Check soon

    Causes

    • Output wire to the traction lock pull solenoid touching a live feed along the harness under the cab floor and at the drive lock plug
    • Dirt or oil in the drive lock plug under the cab floor
    • Controller output stuck on

    Checks

    1. 1With the traction lock pull solenoid unplugged and the output commanded off, check for voltage on the output pin; any voltage shows a stuck driver or a short to a live wire
    2. 2Check the harness under the cab floor and at the drive lock plug for rubbed insulation touching a live wire
    3. 3Check for a drive lock plunger that sticks from oil varnish, so the pull coil cannot release it, which can hold the function on even with the coil off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 15-03Traction lock pull solenoid error OFF

    The traction lock pull solenoid is off when commanded on, so the drive may stay locked.· Other
    Check soon

    Causes

    • Blown fuse on the traction lock pull solenoid feed
    • Open coil
    • Broken wire or loose plug
    • Output driver not switching
    • Dirt or oil in the drive lock plug under the cab floor

    Checks

    1. 1Check the wiring along the harness under the cab floor and at the drive lock plug for continuity and for pins pushed back out of their housings
    2. 2Check for a drive lock plunger that sticks from oil varnish, so the pull coil cannot release it, which can make the coil draw wrongly
    3. 3Check the fuse that supplies the traction lock pull solenoid circuit and replace it if blown, then look for the cause
    4. 4Measure the traction lock pull solenoid coil resistance with the plug off; an open coil reads infinite
    5. 5Check the drive lock itself under the cab for oil leaks or a seized linkage that stops it releasing even with a good coil
    6. 6With the key on and the function commanded, measure the voltage on the output wire at the plug. Then: lower the seat bar and try to drive: the machine should move; raise the bar and the drive should lock again
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 16-05Traction lock hold solenoid short to battery

    The controller found the traction lock hold solenoid circuit tied to battery voltage when it should be able to switch it.· Shorted high
    Check soon

    Causes

    • Output driver in the controller damaged by a prior short
    • Water or corrosion in the traction lock hold solenoid plug bridging output to supply
    • Weak hold stage letting the lock fall back after release

    Checks

    1. 1Inspect the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted for rubbed insulation where a supply wire could touch the traction lock hold solenoid output wire
    2. 2Unplug the traction lock hold solenoid and, with the key on, measure the controller-side output pin to ground; it should not show battery voltage while the output is off
    3. 3With the key off, measure across the traction lock hold solenoid coil pins; a shorted coil reads close to zero and a good one shows a steady resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 16-06Traction lock hold solenoid short to ground

    The controller found the traction lock hold solenoid circuit pulled to ground when it should be able to switch it.· Shorted low
    Check soon

    Causes

    • Wet or corroded plug giving a path to ground
    • Weak hold stage letting the lock fall back after release
    • Coil shorted to its housing
    • Traction lock hold solenoid output wire rubbed through to ground along the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted
    • Harness pinched against a frame bracket

    Checks

    1. 1Check the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted for a pinched or chafed spot against the frame or a bracket
    2. 2Look for water and corrosion in the traction lock hold solenoid plug, and read the traction lock pull solenoid codes
    3. 3Unplug the traction lock hold solenoid and measure the controller-side output wire to ground with the key off; a low reading means a short to ground
    4. 4Listen at the drive lock while lowering the bar; a click followed by a second click a moment later shows the hold stage dropping out
    5. 5Test from each coil pin to the valve body or housing with a meter; any reading means the traction lock hold solenoid coil is shorted to ground
    6. 6Reconnect and clear the code; if it returns at once the coil or the wire to it is grounded. Then: lower the bar and drive a few metres; if drive cuts out after a second or two the hold stage is what is failing, not the pull stage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 16-07Traction lock hold solenoid open circuit

    The controller sees no load on the traction lock hold solenoid circuit, which means the circuit is open.· Open circuit
    Check soon

    Causes

    • Plug not fully seated
    • Pin backed out of the plug
    • Broken wire between the controller and the traction lock hold solenoid

    Checks

    1. 1Pull the plug and check for a pin that has backed out or a terminal that no longer grips the blade
    2. 2Check that the traction lock hold solenoid plug is fully seated and latched on the drive lock beside the pull solenoid, deeper in under the cab
    3. 3Check continuity of both wires between the traction lock hold solenoid plug and the controller with the key off, flexing the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat 17-05Hydraulic lock valve solenoid short to battery

    The controller found the hydraulic lock valve solenoid circuit tied to battery voltage when it should be able to switch it.· Shorted high
    Check soon

    Causes

    • Hydraulic lock valve solenoid wire rubbed against a live feed along the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve
    • Contamination in the lock valve spool bore
    • Coil shorted internally to the supply side

    Checks

    1. 1Inspect the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve for rubbed insulation where a supply wire could touch the hydraulic lock valve solenoid output wire
    2. 2Unplug the hydraulic lock valve solenoid and, with the key on, measure the controller-side output pin to ground; it should not show battery voltage while the output is off
    3. 3With the key off, measure across the hydraulic lock valve solenoid coil pins; a shorted coil reads close to zero and a good one shows a steady resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 17-06Hydraulic lock valve solenoid short to ground

    The hydraulic lock valve coil circuit is shorted to ground.· Shorted low
    Check soon

    Causes

    • Harness pinched against a frame bracket
    • Contamination in the lock valve spool bore
    • Wet or corroded plug giving a path to ground
    • Hydraulic lock valve solenoid output wire rubbed through to ground along the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve
    • Coil shorted to its housing

    Checks

    1. 1Check the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve for a pinched or chafed spot against the frame or a bracket
    2. 2Look for water and corrosion in the hydraulic lock valve solenoid plug, and read the traction lock and seat bar codes in the same interlock group
    3. 3Unplug the hydraulic lock valve solenoid and measure the controller-side output wire to ground with the key off; a low reading means a short to ground
    4. 4Check the hydraulic oil condition and the lock valve block for leaks or dirt; a sticky spool makes the lock misbehave with a good coil
    5. 5Test from each coil pin to the valve body or housing with a meter; any reading means the hydraulic lock valve solenoid coil is shorted to ground
    6. 6Reconnect and clear the code; if it returns at once the coil or the wire to it is grounded. Then: with the bar down, try a short lift and tilt; with the bar up both should lock out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 17-07Hydraulic lock valve solenoid open circuit

    The controller sees no load on the hydraulic lock valve solenoid circuit, which means the circuit is open.· Open circuit
    Check soon

    Causes

    • Coil winding open
    • Pin backed out of the plug
    • Broken wire between the controller and the hydraulic lock valve solenoid
    • Contamination in the lock valve spool bore
    • Plug not fully seated

    Checks

    1. 1Pull the plug and check for a pin that has backed out or a terminal that no longer grips the blade
    2. 2Check that the hydraulic lock valve solenoid plug is fully seated and latched on the loader hydraulic lock valve block
    3. 3Check continuity of both wires between the hydraulic lock valve solenoid plug and the controller with the key off, flexing the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve as you test
    4. 4Measure resistance across the hydraulic lock valve solenoid coil with the plug off; an open coil reads as infinite
    5. 5Check the hydraulic oil condition and the lock valve block for leaks or dirt; a sticky spool makes the lock misbehave with a good coil
    6. 6Repair the wire or replace the coil, then clear the code. Verify: with the bar down, try a short lift and tilt; with the bar up both should lock out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C1029-11Hydraulic lock solenoid short to ground

    The controller reads the hydraulic lock solenoid circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the hydraulic lock solenoid; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the hydraulic lock solenoid
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C1029-12Hydraulic lock solenoid short to battery

    The controller reads the hydraulic lock solenoid circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the hydraulic lock solenoid and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the hydraulic lock solenoid only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1029-13Hydraulic lock solenoid open circuit

    The controller sees an open circuit on the hydraulic lock solenoid, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the hydraulic lock solenoid is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1502Traction lock pull output error on

    The controller sees the traction lock pull solenoid energised when it is commanded off.· Other
    Check soon

    Causes

    • Short to supply on the traction lock pull solenoid output wire
    • Dirt or oil in the drive lock plug under the cab floor
    • Another circuit in the same plug shorting in

    Checks

    1. 1Trace the harness through the harness under the cab floor and at the drive lock plug looking for chafing against a power wire
    2. 2Inspect for a drive lock plunger that sticks from oil varnish, so the pull coil cannot release it
    3. 3Unplug the traction lock pull solenoid and measure the output wire voltage with the output off; it should read zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1503Traction lock pull output error off

    The controller sees the traction lock pull solenoid not energised when it is commanded on.· Other
    Check soon

    Causes

    • Loose or broken connection
    • Dirt or oil in the drive lock plug under the cab floor
    • Fuse or relay feeding the traction lock pull solenoid circuit open

    Checks

    1. 1Inspect the harness under the cab floor and at the drive lock plug for breaks, rubbing and corrosion
    2. 2Check the fuse and relay for the traction lock pull solenoid circuit and test the supply with the key on
    3. 3Measure the voltage at the traction lock pull solenoid plug while the function is commanded; no voltage means a harness or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1507Traction lock pull output open circuit

    The traction lock pull solenoid output circuit is open.· Open circuit
    Check soon

    Causes

    • Wire broken inside the insulation on the drive lock valve, reached under the cab or rear panel
    • Loose or corroded terminal in the plug
    • Dirt or oil in the drive lock plug under the cab floor

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the seat bar, hold solenoid and hydraulic lock valve codes, since the whole interlock group is read together for related faults
    2. 2Check the fuse for the traction lock pull solenoid circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the traction lock pull solenoid for continuity, flexing the harness under the cab floor and at the drive lock plug as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1528Traction lock pull output failure

    The controller has flagged a failure of the traction lock pull solenoid output, which usually follows other output faults.· Other
    Check soon

    Causes

    • Poor connection at the plug
    • Output stage damaged by an earlier fault
    • Wiring fault between the controller and the traction lock pull solenoid

    Checks

    1. 1Look for companion codes such as short, open or overcurrent on the same output, including the seat bar, hold solenoid and hydraulic lock valve codes, since the whole interlock group is read together; they show how the output failed
    2. 2Inspect the harness under the cab floor and at the drive lock plug for rubbing, heat damage and green corrosion in the plugs
    3. 3Check controller power and ground at the plug with the key on and the engine running
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1605Traction lock hold solenoid short to battery

    The traction lock hold solenoid output is shorted to battery voltage, so the controller cannot switch the circuit properly.· Shorted high
    Check soon

    Causes

    • Traction lock hold solenoid winding shorted internally, often from a worn hold plunger or a weak return spring that lets the lock fall back after release
    • Moisture bridging the plug pins
    • Weak hold stage letting the lock fall back after release

    Checks

    1. 1With the traction lock hold solenoid unplugged and the key on, check its output wire for voltage; any voltage while the output is off shows a short to supply
    2. 2Follow the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted looking for melted or rubbed insulation next to supply wires
    3. 3Dry and clean the plug and re-seat it, and read the traction lock pull solenoid codes to see whether other outputs are affected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M1606Traction lock hold solenoid short to ground

    The traction lock hold solenoid output is shorted to ground, so the coil will not energise correctly.· Shorted low
    Check soon

    Causes

    • Weak hold stage letting the lock fall back after release
    • Chafed output wire touching the frame at the hold coil of the drive lock valve, behind the pull solenoid
    • Moisture inside the traction lock hold solenoid connector
    • Harness crushed at a bracket or clamp
    • Coil insulation breakdown

    Checks

    1. 1With the plug off, test the traction lock hold solenoid output wire to chassis ground; a reading near zero shows a harness short to ground
    2. 2Trace the wire through the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted, looking for rubs and sections crushed under clamps
    3. 3Check that the harness clips are in place and not cutting into the wire; compare with the traction lock pull solenoid codes
    4. 4Check resistance from each coil pin to the valve body; any continuity means the coil has failed
    5. 5Listen at the drive lock while lowering the bar; a click followed by a second click a moment later shows the hold stage dropping out
    6. 6Replace the coil or repair the wire, then clear the code and test: lower the bar and drive a few metres; if drive cuts out after a second or two the hold stage is what is failing, not the pull stage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M1607Traction lock hold solenoid open circuit

    The traction lock hold solenoid output circuit is open.· Open circuit
    Check soon

    Causes

    • Open coil
    • Wire broken inside the insulation at the hold coil of the drive lock valve, behind the pull solenoid
    • Loose or corroded terminal in the plug

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the traction lock pull solenoid codes for related faults
    2. 2Check the fuse for the traction lock hold solenoid circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the traction lock hold solenoid for continuity, flexing the short harness spur between the hold coil and the main interlock connector, which gets pinched when the cab is tilted as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1632Hydraulic bypass overcurrent

    The hydraulic bypass solenoid output is drawing too much current.· Lost message
    Check soon

    Causes

    • Bypass spool sticking from dirty oil
    • Partly shorted hydraulic bypass solenoid coil, often from a bypass spool that binds and makes the coil pull too much current
    • Dirt or moisture in the plug

    Checks

    1. 1Inspect the harness at the excavator main control valve, where it is clamped close to hot hydraulic hoses for damage that could create a partial short to ground
    2. 2Open the plug and look for water, dirt or melted plastic that points to heat in the circuit
    3. 3Look for a bypass spool that binds and makes the coil pull too much current, which can overload the output and trip the current limit
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M1705Hydraulic lock valve solenoid short to battery

    The hydraulic lock valve solenoid output is shorted to battery voltage, so the controller cannot switch the circuit properly.· Shorted high
    Check soon

    Causes

    • Hydraulic lock valve solenoid output wire touching a live supply on the lift and tilt lock valve at the control valve
    • Hydraulic lock valve solenoid winding shorted internally, often from a lock valve spool that sticks from contaminated oil and loads the coil
    • Contamination in the lock valve spool bore

    Checks

    1. 1With the hydraulic lock valve solenoid unplugged and the key on, check its output wire for voltage; any voltage while the output is off shows a short to supply
    2. 2Follow the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve looking for melted or rubbed insulation next to supply wires
    3. 3Dry and clean the plug and re-seat it, and read the traction lock and seat bar codes in the same interlock group to see whether other outputs are affected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M1706Hydraulic lock valve solenoid short to ground

    The hydraulic lock valve solenoid output is shorted to ground, so the coil will not energise correctly.· Shorted low
    Check soon

    Causes

    • Moisture inside the hydraulic lock valve solenoid connector
    • Chafed output wire touching the frame on the lift and tilt lock valve at the control valve
    • Coil insulation breakdown
    • Contamination in the lock valve spool bore
    • Harness crushed at a bracket or clamp

    Checks

    1. 1With the plug off, test the hydraulic lock valve solenoid output wire to chassis ground; a reading near zero shows a harness short to ground
    2. 2Trace the wire through the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve, looking for rubs and sections crushed under clamps
    3. 3Check that the harness clips are in place and not cutting into the wire; compare with the traction lock and seat bar codes in the same interlock group
    4. 4Check resistance from each coil pin to the valve body; any continuity means the coil has failed
    5. 5Check the hydraulic oil condition and the lock valve block for leaks or dirt; a sticky spool makes the lock misbehave with a good coil
    6. 6Replace the coil or repair the wire, then clear the code and test: with the bar down, try a short lift and tilt; with the bar up both should lock out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M1707Hydraulic lock valve solenoid open circuit

    The hydraulic lock valve solenoid output circuit is open.· Open circuit
    Check soon

    Causes

    • Contamination in the lock valve spool bore
    • Fuse or feed missing on the supply side
    • Loose or corroded terminal in the plug

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the traction lock and seat bar codes in the same interlock group for related faults
    2. 2Check the fuse for the hydraulic lock valve solenoid circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the hydraulic lock valve solenoid for continuity, flexing the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1732Hydraulic lock valve solenoid overcurrent

    The hydraulic lock valve solenoid output is drawing too much current.· Other
    Check soon

    Causes

    • Partly shorted hydraulic lock valve solenoid coil, often from a lock valve spool that sticks from contaminated oil and loads the coil
    • Contamination in the lock valve spool bore
    • Dirt or moisture in the plug

    Checks

    1. 1Inspect the harness where it drops from the cab to the lift and tilt lock valve at the loader control valve for damage that could create a partial short to ground
    2. 2Open the plug and look for water, dirt or melted plastic that points to heat in the circuit
    3. 3Look for a lock valve spool that sticks from contaminated oil and loads the coil, which can overload the output and trip the current limit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2502Traction pull relay error on

    The controller sees the traction pull relay energised when it is commanded off.· Other
    Check soon

    Causes

    • Coil wire touching a supply wire
    • Interlock relay cycling because of seat bar switching
    • Heat-damaged relay base

    Checks

    1. 1Inspect the base in the interlock relay group for heat marks, melted plastic and loose terminals; read the traction lock solenoid and seat bar codes
    2. 2Remove the traction pull relay and measure the coil pin voltage with the key on and the output off; any voltage is a driver or a wiring problem
    3. 3Raise and lower the seat bar several times and listen to the relay; it should click cleanly each time
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2503Traction pull relay error off

    The controller sees the traction pull relay not energised when it is commanded on.· Other
    Check soon

    Causes

    • Traction pull relay coil failed, often after repeated interlock cycling
    • Open interlock fuse that drops the traction lock relay out
    • Interlock relay cycling because of seat bar switching

    Checks

    1. 1Inspect the socket in the interlock relay group for burnt, loose or spread terminals; read the traction lock solenoid and seat bar codes
    2. 2Check the traction pull relay fuse and the feed along the feed to the traction lock through the interlock relay group with a meter and a test light with the key on
    3. 3Test the relay coil out of the socket; it should show a steady resistance and click when energised
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Lower the seat bar and listen for the solenoid click; no click with voltage at the plug shows a failed coil.
  2. 2Measure each coil resistance with the plug off and compare with the matching coil.
  3. 3Check supply and ground at the plug while the function is commanded.
  4. 4Swap the relay with an identical one when the output reads error on or off.
  5. 5Inspect the harness near the valve block for heat and chafing.

Causes

  • Pull or hold coil burnt open or shorted
  • Relay stuck or socket corroded
  • Wiring chafed near the valve block or traction lock
  • Solenoid plunger sticking in its bore

Most common here: open circuit (6 of 25)

Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

When to stop

You'll notice: Drive or loader hydraulics will not release after the seat bar is lowered, or the lock cannot be set.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.