Bobcat · Safety interlocks
Bobcat Spool, auxiliary, pedal and handle locks fault codes
Spool lock solenoids hold the lift, tilt and auxiliary spools until the operator is in position. Pedal lock and handle lock circuits lock the foot pedals or hand handles out when the seat bar is up.
More about these partsLess
A code names the lock and whether its coil or circuit is shorted or open.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 18-05 to M5432 are all about the spool, auxiliary, pedal and handle locks. The most common failure type is shorted high (10 of 29); none needs an immediate stop. Start with this check: raise and lower the seat bar and watch whether the lock state changes on the service screen.
How urgent are they?
None of the 29 codes here means stop now; all 29 can wait until the shift ends, but find the cause before the next one.
- Check soon29
What should I check first?
Raise and lower the seat bar and watch whether the lock state changes on the service screen.
Shared checks29 of 29
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 18-05Spool lock solenoid short to battery
Spool lock solenoid short to battery: same fault as M1805 (the circuit reads tied to battery voltage), here on the spool lock solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the spool lock solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see M1805.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat 18-06Spool lock solenoid short to ground
Spool lock solenoid short to ground: same fault as M1806 (the circuit reads pulled to ground), here on the spool lock solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The lock solenoid coil shorted to its housing
Checks
- 1Test the spool lock solenoid output wire to chassis ground with the plug off.
- 2Test steps: see M1806.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 18-07Spool lock solenoid open circuit
The controller sees an open circuit on the spool lock, so no current can flow through it and the spool is not locked or not released, so the function is blocked or not held. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the lock solenoid on the valve block
- Wire broken inside its insulation near a bend or clamp
- The lock solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the spool lock connector at the lock solenoid on the valve block is fully seated and its lock tab engaged.
- 2Measure the resistance of the lock solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the spool lock plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat 32-61Handle lock short to ground
Handle lock short to ground: same fault as W1606 (the circuit reads pulled to ground), here on the handle lock.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The handle lock solenoid shorted to its housing
Checks
- 1Test the handle lock output wire to chassis ground with the plug off.
- 2Test steps: see W1606.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 32-62Handle lock short to battery
Handle lock short to battery: same fault as W1605 (the circuit reads tied to battery voltage), here on the handle lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the handle lock and look for voltage on its output wire with the key on.
- 2Test steps: see W1605.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat 32-63Pedal lock short to ground
Pedal lock short to ground: same fault as W1506 (the circuit reads pulled to ground), here on the pedal lock.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The pedal lock solenoid shorted to its housing
Checks
- 1Test the pedal lock output wire to chassis ground with the plug off.
- 2Test steps: see W1506.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 32-64Pedal lock short to battery
Pedal lock short to battery: same fault as W1505 (the circuit reads tied to battery voltage), here on the pedal lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the pedal lock and look for voltage on its output wire with the key on.
- 2Test steps: see W1505.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat W1505Pedal lock short to battery
The controller reads the pedal lock circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the foot pedals will not release or lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the pedal lock solenoid under the floor and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the pedal lock at the pedal lock solenoid under the floor and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the pedal lock solenoid for chafing next to live supply wires and for melted insulation.
- 3Replace the pedal lock solenoid only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat W1506Pedal lock short to ground
The controller reads the pedal lock circuit pulled to ground, so it cannot drive the load. The output is shut off and the foot pedals will not release or lock until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the pedal lock solenoid under the floor
- The pedal lock solenoid shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the pedal lock output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the pedal lock solenoid to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the pedal lock solenoid under the floor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat W1507Pedal lock open circuit
The controller sees an open circuit on the pedal lock, so no current can flow through it and the foot pedals will not release or lock. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the pedal lock solenoid under the floor
- Wire broken inside its insulation near a bend or clamp
- The pedal lock solenoid burnt open or its internal lead broken
Checks
- 1Check that the pedal lock connector at the pedal lock solenoid under the floor is fully seated and its lock tab engaged.
- 2Measure the resistance of the pedal lock solenoid with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the pedal lock plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat W1605Handle lock short to battery
The controller reads the handle lock circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the hand controls will not release or lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the handle lock solenoid at the armrest and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the handle lock at the handle lock solenoid at the armrest and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the handle lock solenoid for chafing next to live supply wires and for melted insulation.
- 3Replace the handle lock solenoid only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat W1606Handle lock short to ground
The controller reads the handle lock circuit pulled to ground, so it cannot drive the load. The output is shut off and the hand controls will not release or lock until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the handle lock solenoid at the armrest
- The handle lock solenoid shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the handle lock output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the handle lock solenoid to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the handle lock solenoid at the armrest.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat W1607Handle lock open circuit
The controller sees an open circuit on the handle lock, so no current can flow through it and the hand controls will not release or lock. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the handle lock solenoid at the armrest
- Wire broken inside its insulation near a bend or clamp
- The handle lock solenoid burnt open or its internal lead broken
Checks
- 1Check that the handle lock connector at the handle lock solenoid at the armrest is fully seated and its lock tab engaged.
- 2Measure the resistance of the handle lock solenoid with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the handle lock plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M1805Spool lock 1 short to battery
The controller reads the spool lock circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the spool is not locked or not released, so the function is blocked or not held.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the lock solenoid on the valve block and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the spool lock at the lock solenoid on the valve block and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the lock solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the lock solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M1806Spool lock 1 short to ground
The controller reads the spool lock circuit pulled to ground, so it cannot drive the load. The output is shut off and the spool is not locked or not released, so the function is blocked or not held until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the lock solenoid on the valve block
- The lock solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the spool lock output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the lock solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the lock solenoid on the valve block.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M1807Spool lock 1 open circuit
Spool lock 1 open circuit: same fault as 18-07 (the circuit is open), here on the spool lock 1.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the spool lock 1 connector is seated, then measure across the part for an open.
- 2Test steps: see 18-07.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M1832Spool lock 1 overcurrent
The controller measured too much current on the spool lock output and switched it off to protect its driver, so the spool is not locked or not released, so the function is blocked or not held until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the lock solenoid on the valve block
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the lock solenoid coil with the plug off and compare it with a matching part on the same machine.
- 2Check the spool lock wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat W3261ACS handle lock short to ground
ACS handle lock short to ground: same fault as W1606 (the circuit reads pulled to ground), here on the handle lock.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The handle lock solenoid shorted to its housing
Checks
- 1Test the handle lock output wire to chassis ground with the plug off.
- 2Test steps: see W1606.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat W3262ACS handle lock short to battery
ACS handle lock short to battery: same fault as W1605 (the circuit reads tied to battery voltage), here on the handle lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the handle lock and look for voltage on its output wire with the key on.
- 2Test steps: see W1605.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat W3263ACS pedal lock short to ground
ACS pedal lock short to ground: same fault as W1506 (the circuit reads pulled to ground), here on the pedal lock.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The pedal lock solenoid shorted to its housing
Checks
- 1Test the pedal lock output wire to chassis ground with the plug off.
- 2Test steps: see W1506.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat W3264ACS pedal lock short to battery
ACS pedal lock short to battery: same fault as W1505 (the circuit reads tied to battery voltage), here on the pedal lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the pedal lock and look for voltage on its output wire with the key on.
- 2Test steps: see W1505.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M3805Auxiliary hydraulic lock short to battery
The controller reads the auxiliary hydraulic lock circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the auxiliary hydraulics will not release or lock.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the auxiliary lock solenoid and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the auxiliary hydraulic lock at the auxiliary lock solenoid and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the lock solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the lock solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M3806Auxiliary hydraulic lock short to ground
The controller reads the auxiliary hydraulic lock circuit pulled to ground, so it cannot drive the load. The output is shut off and the auxiliary hydraulics will not release or lock until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the auxiliary lock solenoid
- The lock solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the auxiliary hydraulic lock output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the lock solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the auxiliary lock solenoid.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M3807Auxiliary hydraulic lock open circuit
The controller sees an open circuit on the auxiliary hydraulic lock, so no current can flow through it and the auxiliary hydraulics will not release or lock. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the auxiliary lock solenoid
- Wire broken inside its insulation near a bend or clamp
- The lock solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the auxiliary hydraulic lock connector at the auxiliary lock solenoid is fully seated and its lock tab engaged.
- 2Measure the resistance of the lock solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the auxiliary hydraulic lock plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M3832Auxiliary hydraulic lock overcurrent
The controller measured too much current on the auxiliary hydraulic lock output and switched it off to protect its driver, so the auxiliary hydraulics will not release or lock until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the auxiliary lock solenoid
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the lock solenoid coil with the plug off and compare it with a matching part on the same machine.
- 2Check the auxiliary hydraulic lock wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M5405Spool lock 2 short to battery
Spool lock 2 short to battery: same fault as M1805 (the circuit reads tied to battery voltage), here on the spool lock 2.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the spool lock 2 and look for voltage on its output wire with the key on.
- 2Test steps: see M1805.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M5406Spool lock 2 short to ground
Spool lock 2 short to ground: same fault as M1806 (the circuit reads pulled to ground), here on the spool lock 2.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The lock solenoid coil shorted to its housing
Checks
- 1Test the spool lock 2 output wire to chassis ground with the plug off.
- 2Test steps: see M1806.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M5407Spool lock 2 open circuit
Spool lock 2 open circuit: same fault as 18-07 (the circuit is open), here on the spool lock 2.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the spool lock 2 connector is seated, then measure across the part for an open.
- 2Test steps: see 18-07.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M5432Spool lock 2 overcurrent
Spool lock 2 overcurrent: same fault as M1832 (the circuit draws more current than the driver allows), here on the spool lock 2.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the spool lock 2 and compare it with a matching part.
- 2Test steps: see M1832.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Raise and lower the seat bar and watch whether the lock state changes on the service screen.
- 2Measure the coil resistance of the named lock solenoid with the plug off.
- 3Check the lock mechanism by hand for binding or a bent linkage.
- 4Look at the connector under the floor or armrest for water and corrosion.
- 5Clear the code and repeat the seat bar cycle to confirm the lock circuit stays healthy.
Causes
- Lock solenoid coil failed or its plunger stuck
- Lock sensor or switch misaligned
- Harness damaged near the pedals or handles
- Connector corrosion under the cab floor or armrest
Most common here: shorted high (10 of 29)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: The lift, tilt, auxiliary or pedal controls are locked out or fail to lock when the seat bar is raised.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
