Bobcat · Operator presence
Bobcat Seat bar, press to operate, cab door and door lock fault codes
The seat bar and seat switch, the press-to-operate switch and light, and the cab door and window switches or door lock tell the controller that an operator is present and ready. Codes name the switch and whether its circuit is shorted or open.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes C10B0-00 to M7974 are all about the seat bar, press to operate, cab door and door lock. The most common failure type is shorted high (4 of 24); none needs an immediate stop. Start with this check: lower the seat bar and sit in the seat while watching the interlock state on the service screen.
How urgent are they?
None of the 24 codes here means stop now; 23 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Check soon23
- Info1
What should I check first?
Lower the seat bar and sit in the seat while watching the interlock state on the service screen.
Shared checks24 of 24
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat C10B0-00Workgroup disabled due to window fault
The controller reports a fault on the workgroup disabled due to window without giving a more exact cause in the list. Treat it as a circuit or part failure.· OtherOtherCheck soonCauses
- Failed part
- Wiring or connector problem
- Controller input or output fault
Checks
- 1Check the plug and wiring of the workgroup disabled due to window for damage and corrosion
- 2Test the part against its normal reading on a matching machine
- 3Have a dealer read the detailed code with the service tool
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 11-05Seat bar sensor short to battery
The seat bar sensor circuit is shorted to supply, so lift/tilt and traction can lock out. Lift, tilt and traction may lock out because the controller cannot confirm the operator is seated.· Shorted highShorted highCheck soonCauses
- Sensor wire rubbed against a supply wire
- Harness pinched at the seat bar pivot
- Seat bar sensor plug wet or corroded
- Sensor failed internally
Checks
- 1Look inside the plug for water and corrosion that could bridge two pins
- 2Check the harness along the seat frame for any other wire rubbing
- 3Unplug the seat bar sensor and measure the signal wire with the key on; it should not show full battery voltage
- 4Test the sensor with the bar in both positions against the wiring diagram states
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat 11-06Seat bar sensor short to ground
The seat bar sensor circuit is shorted to ground. Lift, tilt and traction may lock out because the controller cannot confirm the operator is seated.· Shorted lowShorted lowCheck soonCauses
- Sensor wire chafed to the frame or ground
- Moisture in the connector
- Plug or harness pinched at the pivot
- Sensor internal short to ground
Checks
- 1Check for a loose ring terminal or ground strap touching the sensor circuit
- 2Check the controller input by removing the plug; if the code changes, the wiring is at fault
- 3Unplug the seat bar sensor and measure the signal wire to ground with the key off; low resistance is a short
- 4Check the sensor with the bar raised and lowered to see whether the signal ever changes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat B1080-09Seat bar failure
The controller reports an internal or output failure on the seat bar. The function it drives may be disabled until the cause is found.· OtherOtherCheck soonCauses
- Controller output stage damaged
- Wiring fault that overloads the output
- Failed part on the circuit
Checks
- 1Check the seat bar wiring and plug for shorts, corrosion and chafing
- 2Test the part itself against its resistance spec on a matching machine
- 3If wiring and part are good, suspect the controller output and take it to a dealer
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1080-16Seat bar out of range low
The seat bar signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Open signal wire or missing supply
- Sensor failed low
Checks
- 1Check the supply voltage at the seat bar plug with the key on
- 2Look at the live reading on the display and see if it sits at the bottom of its scale
- 3Test the signal wire to ground with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1080-17Seat bar out of range high
The seat bar signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to supply
- Open sensor ground giving a floating high signal
- Sensor failed high
Checks
- 1Check the ground wire of the seat bar for continuity
- 2Look at the live reading on the display and see if it sits at the top of its scale
- 3Test the signal wire for stray voltage with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1090-00Door open
The controller logged the message "Door open". The code list gives no failure mode beyond the name, so treat it as a status or fault message from the controller.· OtherOtherCheck soonCauses
- Condition the message names is active
- Wiring or connector problem on the related part
- Software or programming mismatch
Checks
- 1Read the message in context with any other active code
- 2Check the related part and its plug for damage
- 3Clear the code and see whether it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1091-16Door sensor out of range low
The door sensor signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Open signal wire or missing supply
- Sensor failed low
Checks
- 1Check the supply voltage at the door sensor plug with the key on
- 2Look at the live reading on the display and see if it sits at the bottom of its scale
- 3Test the signal wire to ground with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1095-13Window sensor open circuit
The controller sees an open circuit on the window sensor, meaning no current can flow through it. The function it drives does not work until the break is repaired.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation near a bend or clamp
- Coil or element burnt open
Checks
- 1Check the connector at the window sensor is fully seated and its lock tab engaged
- 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
- 3Check continuity of each wire from the plug back to the controller connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat B1095-16Window sensor out of range low
The window sensor signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Open signal wire or missing supply
- Sensor failed low
Checks
- 1Check the supply voltage at the window sensor plug with the key on
- 2Look at the live reading on the display and see if it sits at the bottom of its scale
- 3Test the signal wire to ground with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1095-17Window sensor out of range high
The window sensor signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to supply
- Open sensor ground giving a floating high signal
- Sensor failed high
Checks
- 1Check the ground wire of the window sensor for continuity
- 2Look at the live reading on the display and see if it sits at the top of its scale
- 3Test the signal wire for stray voltage with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B1095-95Window sensor failure
The controller reports an internal or output failure on the window sensor. The function it drives may be disabled until the cause is found.· OtherOtherCheck soonCauses
- Controller output stage damaged
- Wiring fault that overloads the output
- Failed part on the circuit
Checks
- 1Check the window sensor wiring and plug for shorts, corrosion and chafing
- 2Test the part itself against its resistance spec on a matching machine
- 3If wiring and part are good, suspect the controller output and take it to a dealer
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M1121Seat bar sensor out of range high
On loaders the seat bar sensor signal reads above its valid range, and lift, tilt and traction may lock out. On excavators this code refers to the console sensor.· OtherOtherCheck soonCauses
- Short to supply or to the 5 V reference wire on the signal wire at the seat bar sensor plug
- Broken return or ground wire at the seat bar sensor
- Pushed-back pin or wet connector at the sensor
- Internal failure of the seat bar sensor that pegs it high
- Seat bar pivot wearing the sensor lead
Checks
- 1Check the signal at the seat bar sensor plug with the key on; it should sit within the normal 0.5-4.5 V span and never at full supply
- 2Look at the harness at the seat bar pivot, which flexes with every use for chafing against a supply wire and for heat damage
- 3Disconnect the plug and probe the controller-side 5 V reference wire; it should read about 5 V where there is one, and the signal pin should not follow battery voltage
- 4Check the lead where it flexes at the seat bar pivot for a cracked outer sleeve and a broken conductor inside
- 5Check the return wire from the seat bar sensor to the controller, along the harness at the seat bar pivot, which flexes with every use, for continuity and for resistance in a corroded splice
- 6Move the bar slowly up and down while watching the signal; it should switch cleanly between the two states. Then: raise and lower the bar and confirm the interlock engages and releases each time
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M1122Seat bar sensor out of range low
The seat bar (or excavator console) sensor reads below its valid range, so the controller may think the bar is up and keep lift and traction locked.· OtherOtherCheck soonCauses
- Failed seat bar sensor reading low
- Loose or unplugged seat bar sensor connector
- Lost 5 V reference wire at the seat bar sensor, or a broken signal wire
- Seat bar pivot wearing the sensor lead
- Signal wire grounded where the harness runs through the harness at the seat bar pivot, which flexes with every use
Checks
- 1Look for green corrosion, pushed-back pins or a missing seal inside the seat bar sensor plug
- 2Measure the 5 V reference wire at the unplugged seat bar sensor connector with the key on; no voltage there means an open supply wire or a controller fault
- 3With the plug removed, a good seat bar sensor signal wire should not read zero ohms to ground; a short means chafed insulation somewhere along the harness at the seat bar pivot, which flexes with every use
- 4Reconnect the seat bar sensor and watch the reading while moving the harness at the seat bar pivot, which flexes with every use; a dropout during movement shows a broken wire
- 5Check the lead where it flexes at the seat bar pivot for a cracked outer sleeve and a broken conductor inside
- 6Move the bar slowly up and down while watching the signal; it should switch cleanly between the two states. Then: raise and lower the bar and confirm the interlock engages and releases each time
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M1128Seat bar sensor failure
The controller judges the seat bar sensor (console sensor on excavators) as failed after bad or implausible signals.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent wiring fault
- Sensor out of adjustment
- Loose mounting at the seat bar
Checks
- 1Inspect the plug and wire for corrosion, wear or a broken conductor close to the pivot
- 2Check the alignment between the sensor and its actuator or magnet when the bar is down
- 3Replace the sensor if the signal is erratic with a good harness
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Bobcat M5202Press to operate switch error on
The controller sees the press to operate switch switched on when it was commanded off. The function may stay active or the circuit may be shorted to supply.· Shorted highShorted highCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck on
- Controller output stage failed
Checks
- 1Unplug the press to operate switch with the key on; if the controller still reads it on, the fault is in the wiring or controller
- 2Check the output wire for contact with a power wire along its run
- 3Listen and feel for the part energising while it should be off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M5221Press to operate switch out of range high
The press to operate switch signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to supply
- Open sensor ground giving a floating high signal
- Sensor failed high
Checks
- 1Check the ground wire of the press to operate switch for continuity
- 2Look at the live reading on the display and see if it sits at the top of its scale
- 3Test the signal wire for stray voltage with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5222Press to operate switch out of range low
The press to operate switch signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Open signal wire or missing supply
- Sensor failed low
Checks
- 1Check the supply voltage at the press to operate switch plug with the key on
- 2Look at the live reading on the display and see if it sits at the bottom of its scale
- 3Test the signal wire to ground with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5305Press to operate light short to battery
The controller reads the press to operate light circuit as tied to battery voltage when it should be switched by the controller. It switches the output off to protect its driver, so the press to operate light stops working. The list gives the same code a different name on M-Series excavators: "Offset rod solenoid error on".· Shorted highShorted highCheck soonCauses
- Output wire rubbed through and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the press to operate light and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
- 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
- 3Replace the press to operate light only if the wire reads clean and the coil or element itself reads shorted
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M5306Press to operate light short to ground
The controller reads the press to operate light circuit pulled to ground, so it cannot drive the load. The output is shut off and the press to operate light does not work until the short is cleared. The list gives the same code a different name on M-Series excavators: "Offset rod solenoid short to ground".· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- Coil or element shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
- 2Measure from each coil pin to the body of the press to operate light; any continuity means the part is shorted
- 3Look for harness sections crushed under clamps or cut by sharp edges near the press to operate light
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H7902Door unlock error on
The controller sees the door unlock switched on when it was commanded off. The function may stay active or the circuit may be shorted to supply.· Shorted highShorted highCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck on
- Controller output stage failed
Checks
- 1Unplug the door unlock with the key on; if the controller still reads it on, the fault is in the wiring or controller
- 2Check the output wire for contact with a power wire along its run
- 3Listen and feel for the part energising while it should be off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M7902Forestry door closed
The controller logged the message "Forestry door closed". The code list gives no failure mode beyond the name, so treat it as a status or fault message from the controller.· OtherOtherInfoCauses
- Condition the message names is active
- Wiring or connector problem on the related part
- Software or programming mismatch
Checks
- 1Read the message in context with any other active code
- 2Check the related part and its plug for damage
- 3Clear the code and see whether it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H7903Door unlock error off
The controller sees the door unlock off when it was commanded on. The function does not work because the circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- Coil or element failed
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the door unlock circuit with the key on
- 2Measure the resistance of the part and look for an open or a short to its body
- 3Command the function and measure voltage at the plug; none means a wiring or controller fault
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M7974Door open
The controller logged the message "Door open". The code list gives no failure mode beyond the name, so treat it as a status or fault message from the controller.· OtherOtherCheck soonCauses
- Condition the message names is active
- Wiring or connector problem on the related part
- Software or programming mismatch
Checks
- 1Read the message in context with any other active code
- 2Check the related part and its plug for damage
- 3Clear the code and see whether it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Lower the seat bar and sit in the seat while watching the interlock state on the service screen.
- 2Check the seat bar sensor alignment and mounting, and its connector under the seat.
- 3Measure the switch circuit with the switch plug off to find open or shorted contacts.
- 4Open and close the door and window while watching the state change on screen.
- 5Wiggle the harness under the seat and cab door while watching for the state to flicker.
Causes
- Seat bar sensor misaligned or its magnet or switch failed
- Switch connector corroded under the seat
- Door or window switch stuck
- Press-to-operate button or lamp circuit failed
Most common here: shorted high (4 of 24)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: The machine will not enable lift, tilt or drive, or interlocks drop out when the operator moves in the seat.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes (flash count table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.