EF Logo

Bobcat · Hydraulics

Bobcat Hydraulic charge pressure, workgroup and load sensing pressure fault codes

Charge pressure keeps the hydrostatic pumps supplied; workgroup pressure sensors read lift base and tilt rod pressure, and load sense and overload sensors read excavator load. Codes are low or high pressure, shutdown-level pressure, and sensor out of range.

FaultCheck05-09Bobcat · Hydraulic charge pressure, workgroup and load sensing pressure
Code shows hereFAULT05-09

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 05-09 to M6222 are all about the hydraulic charge pressure, workgroup and load sensing pressure. The most common failure type is real condition (4 of 27); 6 need an immediate stop. Start with this check: check hydraulic oil level and replace the hydraulic filter if it is due.

How urgent are they?

6 of 27 codes here mean stop now; the other 21 can wait until the shift ends, but find the cause before the next one.

  • Stop now6
  • Check soon21

What should I check first?

Check hydraulic oil level and replace the hydraulic filter if it is due.

Shared checks

27 of 27

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 05-09Hydraulic charge pressure low

    Charge pressure is below normal.· Real condition
    Check soon

    Causes

    • Charge relief valve stuck partly open
    • Plugged charge filter
    • Low hydraulic oil level
    • Worn charge pump

    Checks

    1. 1Check the hydraulic oil level with the loader arms lowered and the bucket flat; low oil starves the charge pump
    2. 2Connect a gauge to the charge pressure test port and compare to the service manual value at the engine speed given there
    3. 3Check the oil for foam, milky colour or a burnt smell; aerated or overheated oil gives low charge pressure
    4. 4If the gauge confirms low pressure and everything else is clean, the charge pump is worn and needs the pump section checked
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat 05-14Hydraulic charge pressure extremely low

    Charge pressure is very low.· Other
    Stop now

    Causes

    • Hydraulic oil nearly gone
    • Charge pump failed
    • Suction line collapsed or drawing air

    Checks

    1. 1Shut down and check the oil level right away; if it is far down, find and fix the leak before refilling
    2. 2Inspect the drive pump coupling to the engine for a sheared drive that leaves the charge pump with no input
    3. 3Check the suction hose for a collapsed inner liner that closes up under flow
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 05-15Hydraulic charge pressure shutdown level

    The engine was shut down because charge pressure fell too low.· Real condition
    Stop now

    Causes

    • Blocked charge filter
    • Pressure transducer failing and reading below the real value
    • Low hydraulic oil level
    • Charge pump worn out

    Checks

    1. 1Check the oil level and top up with the correct hydraulic fluid; a low tank is the cheapest and most common fix
    2. 2Inspect the charge pump and hoses for an air leak or a loose connection on the suction side
    3. 3Verify the hydraulic oil is the correct grade and not overheated, since thin oil bleeds past the pump
    4. 4Replace a plugged charge filter and note whether the machine had been running with the bypass open
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat 05-21Hydraulic charge pressure out of range high

    The hydraulic charge pressure sensor signal reads above its valid electrical range.· Other
    Check soon

    Causes

    • Hydraulic oil weeping into the transducer plug
    • Hydrostatic charge pressure sensor failed high internally
    • Signal wire to the hydrostatic charge pressure sensor shorted to supply along the harness along the hydrostatic pumps and charge filter

    Checks

    1. 1Unplug the hydrostatic charge pressure sensor with the key on; if the controller-side signal wire still shows battery voltage, the harness is shorted to a live wire
    2. 2With the key on and the engine off, back-probe the signal wire at the hydrostatic charge pressure sensor plug; a reading stuck at supply voltage means a short to supply or a sensor failed high
    3. 3With the key off, check continuity of the hydrostatic charge pressure sensor return wire to the controller; an open return makes the signal rise
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 05-22Hydraulic charge pressure out of range low

    The hydraulic charge pressure sensor signal reads below its valid electrical range.· Other
    Check soon

    Causes

    • Signal wire to the hydrostatic charge pressure sensor shorted to ground along the harness along the hydrostatic pumps and charge filter
    • Open 5 V reference wire or open signal wire to the hydrostatic charge pressure sensor
    • Hydraulic oil weeping into the transducer plug

    Checks

    1. 1Unplug the hydrostatic charge pressure sensor and check the signal wire to ground with the key off; low resistance means a short to ground in the harness
    2. 2Check that the hydrostatic charge pressure sensor plug is fully seated, latched and has no backed-out pins or green corrosion
    3. 3Key on and engine off, back-probe the hydrostatic charge pressure sensor plug; the 5 V reference wire should be present and the signal should not sit at zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C101D-16Tilt rod pressure sensor out of range low

    The tilt rod pressure sensor signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the tilt rod pressure sensor plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C101D-17Tilt rod pressure sensor out of range high

    The tilt rod pressure sensor signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the tilt rod pressure sensor for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0509Hydraulic charge pressure low

    Charge pressure in the hydrostatic system is under the normal range.· Other
    Check soon

    Causes

    • Worn charge pump
    • Plugged charge filter
    • Charge relief valve stuck partly open
    • Aerated or hot hydraulic oil

    Checks

    1. 1Inspect the charge filter and its restriction switch; a clogged filter limits flow and drops charge pressure
    2. 2Look at the suction hose between tank and pump for a loose clamp that draws in air and foams the oil
    3. 3Check the charge relief valve for debris or a damaged seat that bleeds pressure to the case
    4. 4Compare the electronic reading with the gauge to rule out the sensor before ordering parts
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0510Hydraulic charge pressure high

    Charge pressure is above the normal range.· Other
    Check soon

    Causes

    • Sensor giving a false high reading
    • Wrong oil grade for the temperature
    • Blocked return from the charge circuit

    Checks

    1. 1Inspect the charge filter and return lines for a blockage that lifts pressure
    2. 2Fit a gauge to the charge test port and compare it with the controller reading
    3. 3Confirm the hydraulic oil grade matches the manual for the operating temperature
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0511Hydraulic charge pressure extremely high

    Charge pressure is far above normal and can damage seals and hoses.· Lost message
    Check soon

    Causes

    • Blocked relief or return passage
    • Sensor failed high
    • Shorted sensor signal wire

    Checks

    1. 1Look for dirt or metal in the charge filter that could be blocking the relief
    2. 2Remove and inspect the charge relief cartridge for a stuck or damaged poppet
    3. 3Compare the gauge to the sensor; if the gauge reads normal the sensor circuit is the problem
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M0514Hydraulic charge pressure extremely low

    Charge pressure is very low and the pumps risk damage.· Other
    Stop now

    Causes

    • Large leak in the charge circuit
    • Charge pump failed
    • Charge relief valve open or sheared

    Checks

    1. 1Check for a visible leak at the charge pump, charge filter housing and test ports
    2. 2Attach a gauge to the charge test port and run only long enough to read it at idle; do not work the machine
    3. 3Examine the charge filter for debris or metal that would point at a failing pump
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0515Hydraulic charge pressure shutdown

    The controller shut the engine down because charge pressure fell below the protection level.· Other
    Stop now

    Causes

    • Pressure transducer failing and reading below the real value
    • Leak between the pump and the filter
    • Blocked charge filter
    • Charge pump worn out

    Checks

    1. 1Check the sensor plug and wiring for water; a wet plug can drop the signal low and trip the shutdown
    2. 2Look at the engine-to-pump coupling for wear that stops the charge pump turning properly
    3. 3Fit a gauge at the charge test port to see whether real pressure is low or the sensor is lying
    4. 4After the repair, restart and hold a gauge on the port while the machine drives to confirm pressure holds under load
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0521Hydraulic charge pressure out of range high

    The charge pressure sensor signal is above its normal electrical range.· Other
    Check soon

    Causes

    • Hydraulic oil weeping into the transducer plug
    • Pushed-back pin or wet connector at the sensor
    • Short to supply or to the 5 V reference wire on the signal wire at the hydrostatic charge pressure sensor plug

    Checks

    1. 1Look at the harness along the hydrostatic pumps and charge filter for chafing against a supply wire and for heat damage
    2. 2Disconnect the plug and probe the controller-side 5 V reference wire; it should read about 5 V where there is one, and the signal pin should not follow battery voltage
    3. 3Check the transducer fitting for leaks and the plug for hydraulic oil, which wicks up the cable and into the connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0522Hydraulic charge pressure out of range low

    The charge pressure sensor signal is below its normal electrical range.· Other
    Check soon

    Causes

    • Lost 5 V reference wire at the hydrostatic charge pressure sensor, or a broken signal wire
    • Hydraulic oil weeping into the transducer plug
    • Loose or unplugged hydrostatic charge pressure sensor connector

    Checks

    1. 1With the plug removed, a good hydrostatic charge pressure sensor signal wire should not read zero ohms to ground; a short means chafed insulation somewhere along the harness along the hydrostatic pumps and charge filter
    2. 2Look for green corrosion, pushed-back pins or a missing seal inside the hydrostatic charge pressure sensor plug
    3. 3Measure the 5 V reference wire at the unplugged hydrostatic charge pressure sensor connector with the key on; no voltage there means an open supply wire or a controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1080-FAHydraulic charge pressure high

    The hydraulic charge pressure reads above its warning level.· Lost message
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the hydraulic charge pressure belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat C1080-FBHydraulic charge pressure extremely high

    The hydraulic charge pressure is far above its normal level.· Other
    Stop now

    Causes

    • Serious overheat or overpressure
    • Blocked cooler or relief valve
    • Sensor reading extremely high

    Checks

    1. 1Stop the machine and let it cool before testing
    2. 2Verify the real value with a separate gauge or probe
    3. 3Check cooler, relief valve and airflow for blockage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1080-F8Hydraulic charge pressure extremely low

    The hydraulic charge pressure is far below its normal level.· Other
    Stop now

    Causes

    • Loss of fluid or pressure
    • Pump or supply failure
    • Sensor reading extremely low

    Checks

    1. 1Stop the machine and check fluid levels first
    2. 2Verify the real value with a separate gauge
    3. 3Check the supply line and pump before suspecting the sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1080-F9Low hydraulic pump pressure

    The controller logged the message "Low hydraulic pump pressure".· Other
    Check soon

    Causes

    • Condition the message names is active
    • Wiring or connector problem on the related part
    • Software or programming mismatch

    Checks

    1. 1Read the message in context with any other active code
    2. 2Check the related part and its plug for damage
    3. 3Clear the code and see whether it returns
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1097-16Hydraulic charge pressure sensor out of range low

    The hydraulic charge pressure sensor signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the hydraulic charge pressure sensor plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1097-17Hydraulic charge pressure sensor out of range high

    The hydraulic charge pressure sensor signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the hydraulic charge pressure sensor for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H1421Lift base pressure out of range high

    The lift base pressure signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the lift base pressure for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H1422Lift base pressure out of range low

    The lift base pressure signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the lift base pressure plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2521Load sense sensor out of range high

    The excavator load-sense pressure sensor signal is above its valid range.· Other
    Check soon

    Causes

    • Internal failure of the load sense pressure sensor that pegs it high
    • Broken return or ground wire at the load sense pressure sensor
    • Short to supply or to the 5 V reference wire on the signal wire at the load sense pressure sensor plug

    Checks

    1. 1Check the signal at the load sense pressure sensor plug with the key on; it should sit within the normal 0.5-4.5 V span and never at full supply
    2. 2Look at the harness at the main control valve on the excavator for chafing against a supply wire and for heat damage
    3. 3Disconnect the plug and probe the controller-side 5 V reference wire; it should read about 5 V where there is one, and the signal pin should not follow battery voltage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2522Load sense sensor out of range low

    The excavator load-sense pressure sensor signal is below its valid range.· Other
    Check soon

    Causes

    • Signal wire grounded where the harness runs through the harness at the main control valve on the excavator
    • Dirt or pressure spikes damaging the load-sense transducer
    • Lost 5 V reference wire at the load sense pressure sensor, or a broken signal wire

    Checks

    1. 1With the plug removed, a good load sense pressure sensor signal wire should not read zero ohms to ground; a short means chafed insulation somewhere along the harness at the main control valve on the excavator
    2. 2Look for green corrosion, pushed-back pins or a missing seal inside the load sense pressure sensor plug
    3. 3Measure the 5 V reference wire at the unplugged load sense pressure sensor connector with the key on; no voltage there means an open supply wire or a controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6204Load moment sensor in error

    The controller reports a fault on the load moment sensor without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the load moment sensor for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6221Overload warning sensor out of range high

    The overload warning sensor signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Real condition
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the overload warning sensor for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat M6222Overload warning sensor out of range low

    The overload warning sensor signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Real condition
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the overload warning sensor plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check hydraulic oil level and replace the hydraulic filter if it is due.
  2. 2Compare the service screen pressure with a gauge at the test port before blaming the sensor.
  3. 3Check the sensor 5 V supply and ground and look for water in the connector.
  4. 4Listen for a noisy charge pump suggesting air in the suction line.
  5. 5Clear and retest under load to see whether the code returns.

Causes

  • Low hydraulic oil or blocked suction filter
  • Charge pump worn or relief valve stuck
  • Pressure sensor wiring or connector fault
  • Sensor failed out of range

Most common here: real condition (4 of 27)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A charge pressure warning shows, drive is weak or the loader hydraulics are slow, or an overload warning is wrong.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.