Bobcat · Hydraulics
Bobcat E145/E165 pump, flow control and travel valves fault codes
The E145 and E165 excavators drive their pumps, flow control valves and travel valves with proportional solenoids. A code names the valve and whether its circuit is open, shorted to ground or battery, or has an output error.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes VPV001-05 to VSV012-06 are all about the e145/E165 pump, flow control and travel valves. The most common failure type is shorted low (19 of 38); none needs an immediate stop. Start with this check: measure each proportional solenoid coil resistance with the plug off, then compare it with the next valve.
How urgent are they?
None of the 38 codes here means stop now; all 38 can wait until the shift ends, but find the cause before the next one.
- Check soon38
What should I check first?
Measure each proportional solenoid coil resistance with the plug off, then compare it with the next valve.
Shared checks38 of 38
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat VPV001-05Pump P/V (a), current below normal
The controller measured less current than expected through the solenoid valve while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the solenoid valve does not respond, so travel, swing or pump selection is limited.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded at the valve connector on the main valve
- Wire broken near a bend
- Controller output weak
Checks
- 1Measure the resistance of the solenoid coil with the plug off; an open or very high reading confirms the part.
- 2Check the solenoid valve connector at the valve connector on the main valve for corrosion and for pins pushed back in the shell.
- 3Check the wire for resistance between the controller and the plug while flexing the harness.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV001-06Pump P/V (a), current above normal
The controller measured more current than expected through the solenoid valve while commanding it, which points to a shorted coil or a wire shorted to ground, and the solenoid valve does not respond, so travel, swing or pump selection is limited until it is cleared.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground at the valve connector on the main valve
- Water in the connector
- Wrong part fitted
Checks
- 1Measure the resistance of the solenoid coil with the plug off and compare it with a matching part.
- 2Test the solenoid valve output wire to ground with the plug off for a short.
- 3Look at the harness at the valve connector on the main valve for chafing that shorts to ground only when the machine moves.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV002-05Pump P/V (b), current below normal
Pump P/V (b), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the pump p v b.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the pump p v b with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV002-06Pump P/V (b), current above normal
Pump P/V (b), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the pump p v b.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the pump p v b wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV003-05Flow control P/V (g), current below normal
Flow control P/V (g), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the flow control p v g.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the flow control p v g with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV003-05High speed S/V (c), current below normal
High speed S/V (c), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the high speed s v c.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the high speed s v c with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV003-06Flow control P/V (g), current above normal
Flow control P/V (g), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the flow control p v g.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the flow control p v g wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV003-06High speed S/V (c), current above normal
High speed S/V (c), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the high speed s v c.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the high speed s v c wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV005-05Press. control 1 P/V (h), current below normal
Press. control 1 P/V (h), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the press control 1 p v h.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the press control 1 p v h with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV005-05Travel II pump confluence s/v, current below normal
Travel II pump confluence s/v, current below normal: same fault as VPV001-05 (the controller measured too little current), here on the travel ii pump confluence s v.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the travel ii pump confluence s v with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV005-06Press. control 1 P/V (h), current above normal
Press. control 1 P/V (h), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the press control 1 p v h.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the press control 1 p v h wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV005-06Travel II pump confluence s/v, current above normal
Travel II pump confluence s/v, current above normal: same fault as VPV001-06 (the controller measured too much current), here on the travel ii pump confluence s v.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the travel ii pump confluence s v wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV006-05Press. control 2 P/V (i), current below normal
Press. control 2 P/V (i), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the press control 2 p v i.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the press control 2 p v i with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV006-05Swing brake release S/V (k), current below normal
Swing brake release S/V (k), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the swing brake release s v k.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the swing brake release s v k with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV006-06Press. control 2 P/V (i), current above normal
Press. control 2 P/V (i), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the press control 2 p v i.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the press control 2 p v i wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV006-06Swing brake release S/V (k), current above normal
Swing brake release S/V (k), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the swing brake release s v k.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the swing brake release s v k wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV007-05Flow control P/V (c) 2-way rh-open, current below normal
Flow control P/V (c) 2-way rh-open, current below normal: same fault as VPV001-05 (the controller measured too little current), here on the flow control p v c 2 way rh open.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the flow control p v c 2 way rh open with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV007-06Flow control P/V (c) 2-way rh-open, current above normal
Flow control P/V (c) 2-way rh-open, current above normal: same fault as VPV001-06 (the controller measured too much current), here on the flow control p v c 2 way rh open.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the flow control p v c 2 way rh open wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV008-05Flow control P/V (d) 2-way rh-close, current below normal
Flow control P/V (d) 2-way rh-close, current below normal: same fault as VPV001-05 (the controller measured too little current), here on the flow control p v d 2 way rh close.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the flow control p v d 2 way rh close with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV008-05Cruise S/V (f), current below normal
Cruise S/V (f), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the cruise s v f.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the cruise s v f with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV008-06Flow control P/V (d) 2-way rh-close, current above normal
Flow control P/V (d) 2-way rh-close, current above normal: same fault as VPV001-06 (the controller measured too much current), here on the flow control p v d 2 way rh close.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the flow control p v d 2 way rh close wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV008-06Cruise S/V (f), current above normal
Cruise S/V (f), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the cruise s v f.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the cruise s v f wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV009-05Flow control P/V (e) rotating cw, current below normal
Flow control P/V (e) rotating cw, current below normal: same fault as VPV001-05 (the controller measured too little current), here on the flow control p v e rotating cw.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the flow control p v e rotating cw with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV009-05Forward S/V (g), current below normal
Forward S/V (g), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the forward s v g.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the forward s v g with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV009-06Flow control P/V (e) rotating cw, current above normal
Flow control P/V (e) rotating cw, current above normal: same fault as VPV001-06 (the controller measured too much current), here on the flow control p v e rotating cw.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the flow control p v e rotating cw wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV009-06Forward S/V (g), current above normal
Forward S/V (g), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the forward s v g.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the forward s v g wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV010-05Flow control P/V (f) rotating ccw, current below normal
Flow control P/V (f) rotating ccw, current below normal: same fault as VPV001-05 (the controller measured too little current), here on the flow control p v f rotating ccw.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the flow control p v f rotating ccw with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV010-05Reverse S/V (h), current below normal
Reverse S/V (h), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the reverse s v h.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the reverse s v h with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV010-06Flow control P/V (f) rotating ccw, current above normal
Flow control P/V (f) rotating ccw, current above normal: same fault as VPV001-06 (the controller measured too much current), here on the flow control p v f rotating ccw.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the flow control p v f rotating ccw wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV010-06Reverse S/V (h), current above normal
Reverse S/V (h), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the reverse s v h.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the reverse s v h wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV011-05Travel, current below normal
The controller measured less current than expected through the proportional valve while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the proportional valve does not follow its command, so pump or flow function is limited.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded at the valve connector on the main valve
- Wire broken near a bend
- Controller output weak
Checks
- 1Measure the resistance of the proportional coil with the plug off; an open or very high reading confirms the part.
- 2Check the proportional valve connector at the valve connector on the main valve for corrosion and for pins pushed back in the shell.
- 3Check the wire for resistance between the controller and the plug while flexing the harness.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV011-052 pump select S/V (i), current below normal
2 pump select S/V (i), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the 2 pump select s v i.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the 2 pump select s v i with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV011-06Travel, current above normal
The controller measured more current than expected through the proportional valve while commanding it, which points to a shorted coil or a wire shorted to ground, and the proportional valve does not follow its command, so pump or flow function is limited until it is cleared.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground at the valve connector on the main valve
- Water in the connector
- Wrong part fitted
Checks
- 1Measure the resistance of the proportional coil with the plug off and compare it with a matching part.
- 2Test the proportional valve output wire to ground with the plug off for a short.
- 3Look at the harness at the valve connector on the main valve for chafing that shorts to ground only when the machine moves.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV011-062 pump select S/V (i), current above normal
2 pump select S/V (i), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the 2 pump select s v i.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the 2 pump select s v i wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VPV012-05Travel straight P/V (l), current below normal
Travel straight P/V (l), current below normal: same fault as VPV011-05 (the controller measured too little current), here on the travel straight p v l.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the travel straight p v l with the plug off and check its connector.
- 2Test steps: see VPV011-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV012-05Bypass cut off S/V (j), current below normal
Bypass cut off S/V (j), current below normal: same fault as VPV001-05 (the controller measured too little current), here on the bypass cut off s v j.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded
Checks
- 1Measure the resistance of the bypass cut off s v j with the plug off and check its connector.
- 2Test steps: see VPV001-05.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV012-06Travel straight P/V (l), current above normal
Travel straight P/V (l), current above normal: same fault as VPV011-06 (the controller measured too much current), here on the travel straight p v l.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the travel straight p v l wire to ground and measure the coil resistance.
- 2Test steps: see VPV011-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV012-06Bypass cut off S/V (j), current above normal
Bypass cut off S/V (j), current above normal: same fault as VPV001-06 (the controller measured too much current), here on the bypass cut off s v j.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground
Checks
- 1Test the bypass cut off s v j wire to ground and measure the coil resistance.
- 2Test steps: see VPV001-06.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Measure each proportional solenoid coil resistance with the plug off, then compare it with the next valve.
- 2Check the connector at the valve for water and bent pins before testing wiring.
- 3Compare the commanded current on the service screen with the actual response of the function.
- 4Check supply and ground at the plug while the function is commanded.
- 5Inspect harness routing through the boom and frame for chafing.
Causes
- Proportional coil shorted or open
- Harness chafed in the boom or frame routing
- Connector corrosion at the valve
- Valve spool sticking
Most common here: shorted low (19 of 38)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: A pump, a function or travel is slow, weak or dead on one side.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.