Bobcat Lift and tilt spool solenoids, ride control and valves fault codes

The base and rod solenoids on the lift and tilt spool sections drive the arms and bucket in each direction, while ride control, the bucket position solenoid, the dump valve and the direct to tank valve handle damping and unloading. A code names the solenoid and its failure.

FaultCheck19-02Bobcat · Lift and tilt spool solenoids, ride control and valves
Code shows hereFAULT19-02

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 19-02 to M6932 are all about the lift and tilt spool solenoids, ride control and valves. The most common failure type is shorted low (11 of 38); none needs an immediate stop. Start with this check: measure each solenoid coil resistance with the plug off and compare with its pair.

How urgent are they?

None of the 38 codes here means stop now; all 38 can wait until the shift ends, but find the cause before the next one.

  • Check soon38

What should I check first?

Measure each solenoid coil resistance with the plug off and compare with its pair.

Shared checks

38 of 38

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 19-02Bucket position solenoid error on

    The controller sees the bucket position solenoid switched on when it was commanded off, so the solenoid stays energised.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the bucket position solenoid at the bucket position solenoid with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the solenoid coil energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 19-03Bucket position solenoid error off

    The controller sees the bucket position solenoid off when it was commanded on, so the bucket position function does not hold.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The solenoid coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the bucket position solenoid circuit with the key on.
    2. 2Measure the resistance of the solenoid coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the bucket position solenoid plug; none means a wiring or controller fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103A-11Ride control 1 short to ground

    The controller reads the ride control circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the ride control valve on the lift arm
    • The ride control solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the ride control output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the ride control solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the ride control valve on the lift arm.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103B-11Ride control 2 short to ground

    Ride control 2 short to ground: same fault as C103A-11 (the circuit reads pulled to ground), here on the ride control 2.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • The ride control solenoid coil shorted to its housing

    Checks

    1. 1Test the ride control 2 output wire to chassis ground with the plug off.
    2. 2Test steps: see C103A-11.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103A-12Ride control 1 short to battery

    The controller reads the ride control circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the ride control valve on the lift arm and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the ride control at the ride control valve on the lift arm and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the ride control solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the ride control solenoid coil only if the wire reads clean and the part itself reads shorted.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C103B-12Ride control 2 short to battery

    Ride control 2 short to battery: same fault as C103A-12 (the circuit reads tied to battery voltage), here on the ride control 2.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through
    • Water or corrosion in the plug bridging a pin to a power pin

    Checks

    1. 1Unplug the ride control 2 and look for voltage on its output wire with the key on.
    2. 2Test steps: see C103A-12.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C103A-13Ride control 1 open circuit

    The controller sees an open circuit on the ride control, so no current can flow through it and the ride control damping does not engage.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the ride control valve on the lift arm
    • Wire broken inside its insulation near a bend or clamp
    • The ride control solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the ride control connector at the ride control valve on the lift arm is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the ride control solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the ride control plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C103B-13Ride control 2 open circuit

    Ride control 2 open circuit: same fault as C103A-13 (the circuit is open), here on the ride control 2.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the ride control 2 connector is seated, then measure across the part for an open.
    2. 2Test steps: see C103A-13.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H0905Direct to tank short to battery

    The controller reads the direct to tank circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the valve block connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the direct to tank at the valve block connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the valve coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the valve coil only if the wire reads clean and the part itself reads shorted.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H0906Direct to tank short to ground

    The controller reads the direct to tank circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the valve block connector
    • The valve coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the direct to tank output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the valve coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the valve block connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H0907Direct to tank open circuit

    The controller sees an open circuit on the direct to tank, so no current can flow through it and the valve does not unload or hold as commanded.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the valve block connector
    • Wire broken inside its insulation near a bend or clamp
    • The valve coil burnt open or its internal lead broken

    Checks

    1. 1Check that the direct to tank connector at the valve block connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the valve coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the direct to tank plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H0932Direct to tank overcurrent

    The controller measured too much current on the direct to tank output and switched it off to protect its driver, so the valve does not unload or hold as commanded until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the valve block connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the valve coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the direct to tank wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat W1005Lift base solenoid short to battery

    The controller reads the lift or tilt spool solenoid circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the lift or tilt valve section connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the lift or tilt spool solenoid at the lift or tilt valve section connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the spool solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the spool solenoid coil only if the wire reads clean and the part itself reads shorted.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W1006Lift base solenoid short to ground

    The controller reads the lift or tilt spool solenoid circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the lift or tilt valve section connector
    • The spool solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the lift or tilt spool solenoid output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the spool solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the lift or tilt valve section connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W1007Lift base solenoid open circuit

    The controller sees an open circuit on the lift or tilt spool solenoid, so no current can flow through it and the lift arms or the bucket do not move in the direction that solenoid controls.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the lift or tilt valve section connector
    • Wire broken inside its insulation near a bend or clamp
    • The spool solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the lift or tilt spool solenoid connector at the lift or tilt valve section connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the spool solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the lift or tilt spool solenoid plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat W1032Lift base solenoid overcurrent

    The controller measured too much current on the lift or tilt spool solenoid output and switched it off to protect its driver, so the lift arms or the bucket do not move in the direction that solenoid controls until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the lift or tilt valve section connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the spool solenoid coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the lift or tilt spool solenoid wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat W1105Lift rod solenoid short to battery

    Lift rod solenoid short to battery: same fault as W1005 (the circuit reads tied to battery voltage), here on the lift rod solenoid.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through
    • Water or corrosion in the plug bridging a pin to a power pin

    Checks

    1. 1Unplug the lift rod solenoid and look for voltage on its output wire with the key on.
    2. 2Test steps: see W1005.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W1106Lift rod solenoid short to ground

    Lift rod solenoid short to ground: same fault as W1006 (the circuit reads pulled to ground), here on the lift rod solenoid.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • The spool solenoid coil shorted to its housing

    Checks

    1. 1Test the lift rod solenoid output wire to chassis ground with the plug off.
    2. 2Test steps: see W1006.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W1107Lift rod solenoid open circuit

    Lift rod solenoid open circuit: same fault as W1007 (the circuit is open), here on the lift rod solenoid.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the lift rod solenoid connector is seated, then measure across the part for an open.
    2. 2Test steps: see W1007.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat W1132Lift rod solenoid overcurrent

    Lift rod solenoid overcurrent: same fault as W1032 (the circuit draws more current than the driver allows), here on the lift rod solenoid.· Other
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground

    Checks

    1. 1Measure the resistance of the lift rod solenoid and compare it with a matching part.
    2. 2Test steps: see W1032.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W1205Tilt base solenoid short to battery

    Tilt base solenoid short to battery: same fault as W1005 (the circuit reads tied to battery voltage), here on the tilt base solenoid.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through
    • Water or corrosion in the plug bridging a pin to a power pin

    Checks

    1. 1Unplug the tilt base solenoid and look for voltage on its output wire with the key on.
    2. 2Test steps: see W1005.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W1206Tilt base solenoid short to ground

    Tilt base solenoid short to ground: same fault as W1006 (the circuit reads pulled to ground), here on the tilt base solenoid.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • The spool solenoid coil shorted to its housing

    Checks

    1. 1Test the tilt base solenoid output wire to chassis ground with the plug off.
    2. 2Test steps: see W1006.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W1207Tilt base solenoid open circuit

    Tilt base solenoid open circuit: same fault as W1007 (the circuit is open), here on the tilt base solenoid.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the tilt base solenoid connector is seated, then measure across the part for an open.
    2. 2Test steps: see W1007.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat W1232Tilt base solenoid overcurrent

    Tilt base solenoid overcurrent: same fault as W1032 (the circuit draws more current than the driver allows), here on the tilt base solenoid.· Other
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground

    Checks

    1. 1Measure the resistance of the tilt base solenoid and compare it with a matching part.
    2. 2Test steps: see W1032.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W1305Tilt rod solenoid short to battery

    Tilt rod solenoid short to battery: same fault as W1005 (the circuit reads tied to battery voltage), here on the tilt rod solenoid.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through
    • Water or corrosion in the plug bridging a pin to a power pin

    Checks

    1. 1Unplug the tilt rod solenoid and look for voltage on its output wire with the key on.
    2. 2Test steps: see W1005.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W1306Tilt rod solenoid short to ground

    Tilt rod solenoid short to ground: same fault as W1006 (the circuit reads pulled to ground), here on the tilt rod solenoid.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • The spool solenoid coil shorted to its housing

    Checks

    1. 1Test the tilt rod solenoid output wire to chassis ground with the plug off.
    2. 2Test steps: see W1006.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W1307Tilt rod solenoid open circuit

    Tilt rod solenoid open circuit: same fault as W1007 (the circuit is open), here on the tilt rod solenoid.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the tilt rod solenoid connector is seated, then measure across the part for an open.
    2. 2Test steps: see W1007.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat W1332Tilt rod solenoid overcurrent

    Tilt rod solenoid overcurrent: same fault as W1032 (the circuit draws more current than the driver allows), here on the tilt rod solenoid.· Other
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground

    Checks

    1. 1Measure the resistance of the tilt rod solenoid and compare it with a matching part.
    2. 2Test steps: see W1032.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H1502Ride control relay error on

    The controller sees the ride control relay switched on when it was commanded off, so the ride control stays engaged.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the ride control relay at the ride control valve on the lift arm with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the ride control solenoid coil energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H1503Ride control relay error off

    The controller sees the ride control relay off when it was commanded on, so the ride control damping does not engage.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The ride control solenoid coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the ride control relay circuit with the key on.
    2. 2Measure the resistance of the ride control solenoid coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the ride control relay plug; none means a wiring or controller fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H1602Ride control output error on

    The controller sees the ride control output switched on when it was commanded off, so the ride control stays engaged.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the ride control output at the ride control valve on the lift arm with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the ride control solenoid coil energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H1603Ride control output error off

    The controller sees the ride control output off when it was commanded on, so the ride control damping does not engage.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The ride control solenoid coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the ride control output circuit with the key on.
    2. 2Measure the resistance of the ride control solenoid coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the ride control output plug; none means a wiring or controller fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H1607Ride control output open circuit

    The controller sees an open circuit on the ride control output, so no current can flow through it and the ride control damping does not engage.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the ride control valve on the lift arm
    • Wire broken inside its insulation near a bend or clamp
    • The ride control solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the ride control output connector at the ride control valve on the lift arm is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the ride control solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the ride control output plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H1628Ride control output failure

    The controller reports a failure on the ride control output without saying whether it is open, shorted or stuck, so the ride control damping does not engage.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the ride control valve on the lift arm
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the ride control output; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the ride control valve on the lift arm and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6905Dump valve short to battery

    The controller reads the dump valve circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the valve block connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the dump valve at the valve block connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the valve coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the valve coil only if the wire reads clean and the part itself reads shorted.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M6906Dump valve short to ground

    The controller reads the dump valve circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the valve block connector
    • The valve coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the dump valve output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the valve coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the valve block connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M6907Dump valve open circuit

    The controller sees an open circuit on the dump valve, so no current can flow through it and the valve does not unload or hold as commanded.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the valve block connector
    • Wire broken inside its insulation near a bend or clamp
    • The valve coil burnt open or its internal lead broken

    Checks

    1. 1Check that the dump valve connector at the valve block connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the valve coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the dump valve plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M6932Dump valve overcurrent

    The controller measured too much current on the dump valve output and switched it off to protect its driver, so the valve does not unload or hold as commanded until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the valve block connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the valve coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the dump valve wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Measure each solenoid coil resistance with the plug off and compare with its pair.
  2. 2Check the connector at the valve block and look for water and bent pins.
  3. 3Measure voltage at the plug while the function is commanded.
  4. 4Check the ride control switch and accumulator when only damping is affected.
  5. 5Inspect the harness along the valve block for heat damage.

Causes

  • Solenoid coil shorted or open
  • Wire chafed on the valve block bracket
  • Connector corroded or pin backed out
  • Valve spool sticking from contaminated oil

Most common here: shorted low (11 of 38)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: A lift or tilt direction is dead, the ride is harsh, or the bucket will not hold its position.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.