The lift and tilt actuators are the electro-hydraulic valve sections that move the lift arms and bucket. Codes report the actuator or its coil circuit as shorted, open, not responding, or not reaching its commanded position.

FaultCheck32-31Bobcat · Lift and tilt actuators
Code shows hereFAULT32-31

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 32-31 to W3260 are all about the lift and tilt actuators. The most common failure type is shorted high (6 of 40); none needs an immediate stop. Start with this check: command lift and tilt from the service screen and watch the actuator command against its feedback.

How urgent are they?

None of the 40 codes here means stop now; all 40 can wait until the shift ends, but find the cause before the next one.

  • Check soon40

What should I check first?

Command lift and tilt from the service screen and watch the actuator command against its feedback.

Shared checks

40 of 40

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 32-31Tilt actuator fault

    The controller reports a fault on the tilt actuator without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the tilt actuator for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-32Tilt actuator wiring fault

    The controller reports a fault on the tilt actuator wiring without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the tilt actuator wiring for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-34Tilt actuator not in neutral

    The controller sees the tilt actuator away from neutral when it should be centred.· Real condition
    Check soon

    Causes

    • Control held away from centre by the operator or an object
    • Sensor out of calibration
    • Spring or mechanical return not centring

    Checks

    1. 1Release the control completely and key off, then on, to see whether the code clears
    2. 2Check the control returns to centre freely and nothing pushes on it
    3. 3Recalibrate the control if the manual allows and the code returns at rest
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat 32-36Lift actuator fault

    The controller reports a fault on the lift actuator without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the lift actuator for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-37Lift actuator wiring fault

    The controller reports a fault on the lift actuator wiring without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the lift actuator wiring for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-39Lift actuator not in neutral

    The controller sees the lift actuator away from neutral when it should be centred.· Real condition
    Check soon

    Causes

    • Control held away from centre by the operator or an object
    • Sensor out of calibration
    • Spring or mechanical return not centring

    Checks

    1. 1Release the control completely and key off, then on, to see whether the code clears
    2. 2Check the control returns to centre freely and nothing pushes on it
    3. 3Recalibrate the control if the manual allows and the code returns at rest
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat 32-49Lift actuator short to ground

    The controller reads the lift actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the lift actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the lift actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 32-50Tilt actuator short to ground

    The controller reads the tilt actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the tilt actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the tilt actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 32-51Lift actuator short to battery

    The controller reads the lift actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the lift actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the lift actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 32-52Tilt actuator short to battery

    The controller reads the tilt actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the tilt actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the tilt actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 32-57Lift actuator reduced performance

    The controller reports a performance problem on the lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-58Tilt actuator reduced performance

    The controller reports a performance problem on the tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-59Lift actuator wrong direction

    The controller reports a performance problem on the lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-60Tilt actuator wrong direction

    The controller reports a performance problem on the tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1040-11Lift actuator short to ground

    The controller reads the lift actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the lift actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the lift actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C1040-12Lift actuator short to battery

    The controller reads the lift actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the lift actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the lift actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1040-13Lift actuator open circuit

    The controller sees an open circuit on the lift actuator, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the lift actuator is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C1040-19Lift actuator overcurrent

    The controller measured too much current on the lift actuator output and switched it off to protect its driver.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the coil resistance of the lift actuator with the plug off and compare with a matching part on the same machine
    2. 2Check the wire for a partial short to ground that only shows when the machine is hot or vibrating
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat C1040-77Lift actuator reduced performance

    The controller reports a performance problem on the lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1042-00Lift actuator uncommanded motion

    The controller reports a performance problem on the lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1045-11Tilt actuator short to ground

    The controller reads the tilt actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the tilt actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the tilt actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C1045-12Tilt actuator short to battery

    The controller reads the tilt actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the tilt actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the tilt actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1045-13Tilt actuator open circuit

    The controller sees an open circuit on the tilt actuator, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the tilt actuator is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C1045-19Tilt actuator overcurrent

    The controller measured too much current on the tilt actuator output and switched it off to protect its driver.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the coil resistance of the tilt actuator with the plug off and compare with a matching part on the same machine
    2. 2Check the wire for a partial short to ground that only shows when the machine is hot or vibrating
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat C1045-77Tilt actuator reduced performance

    The controller reports a performance problem on the tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1047-00Tilt actuator uncommanded motion

    The controller reports a performance problem on the tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3231ACS/AHC tilt actuator fault

    The controller reports a fault on the acs/ahc tilt actuator without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the acs/ahc tilt actuator for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3232AHC tilt actuator wiring fault

    The controller reports a fault on the ahc tilt actuator wiring without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the ahc tilt actuator wiring for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3234ACS/AHC tilt actuator not in neutral

    The controller sees the acs/ahc tilt actuator away from neutral when it should be centred.· Real condition
    Check soon

    Causes

    • Control held away from centre by the operator or an object
    • Sensor out of calibration
    • Spring or mechanical return not centring

    Checks

    1. 1Release the control completely and key off, then on, to see whether the code clears
    2. 2Check the control returns to centre freely and nothing pushes on it
    3. 3Recalibrate the control if the manual allows and the code returns at rest
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat W3236ACS/AHC lift actuator fault

    The controller reports a fault on the acs/ahc lift actuator without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the acs/ahc lift actuator for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3237AHC lift actuator wiring fault

    The controller reports a fault on the ahc lift actuator wiring without giving a more exact cause in the list.· Other
    Check soon

    Causes

    • Failed part
    • Wiring or connector problem
    • Controller input or output fault

    Checks

    1. 1Check the plug and wiring of the ahc lift actuator wiring for damage and corrosion
    2. 2Test the part against its normal reading on a matching machine
    3. 3Have a dealer read the detailed code with the service tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3239ACS/AHC lift actuator not in neutral

    The controller sees the acs/ahc lift actuator away from neutral when it should be centred.· Real condition
    Check soon

    Causes

    • Control held away from centre by the operator or an object
    • Sensor out of calibration
    • Spring or mechanical return not centring

    Checks

    1. 1Release the control completely and key off, then on, to see whether the code clears
    2. 2Check the control returns to centre freely and nothing pushes on it
    3. 3Recalibrate the control if the manual allows and the code returns at rest
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat W3249ACS lift actuator short to ground

    The controller reads the acs lift actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the acs lift actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the acs lift actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W3250ACS tilt actuator short to ground

    The controller reads the acs tilt actuator circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the acs tilt actuator; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the acs tilt actuator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat W3251ACS lift actuator short to battery

    The controller reads the acs lift actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the acs lift actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the acs lift actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W3252ACS tilt actuator short to battery

    The controller reads the acs tilt actuator circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the acs tilt actuator and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the acs tilt actuator only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat W3257ACS lift actuator reduced performance

    The controller reports a performance problem on the acs lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the acs lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3258ACS tilt actuator reduced performance

    The controller reports a performance problem on the acs tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the acs tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3259ACS lift actuator wrong direction

    The controller reports a performance problem on the acs lift actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the acs lift actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3260ACS tilt actuator wrong direction

    The controller reports a performance problem on the acs tilt actuator, such as reduced response, wrong direction, uncommanded motion or a position that cannot be reached.· Other
    Check soon

    Causes

    • Worn or sticking part
    • Low supply voltage or poor ground
    • Calibration out of date

    Checks

    1. 1Check the acs tilt actuator moves freely and without binding
    2. 2Check supply voltage and ground at its plug
    3. 3Recalibrate if the manual allows and retest
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Command lift and tilt from the service screen and watch the actuator command against its feedback.
  2. 2Measure coil resistance for each actuator with the plug off.
  3. 3Check the harness at the valve block for chafing and heat.
  4. 4Replace the hydraulic filter and check oil condition if the spool is sticking.
  5. 5Run the workgroup calibration after any valve or sensor replacement.

Causes

  • Actuator coil shorted, open or overheated
  • Spool sticking from contaminated oil
  • Harness damaged near the valve block
  • Position feedback not matching the command

Most common here: shorted high (6 of 40)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The loader arms or bucket move slowly, not at all, or only in one direction.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.