John Deere · Main controller (MCZ) - pressure sensors

John Deere Pump pressure and hydraulic oil temperature sensors fault codes

The main controller (MCZ) reads the heart of the hydraulic system through these sensors. B35 and B37 read the delivery pressure of pump 1 and pump 2, B36 and B38 read the regulator (control) pressure that sets each pump displacement, and a further sensor reads the hydraulic fan pump.

More about these parts

B40 is the main hydraulic oil temperature sensor and B68 a second one in the pilot circuit. Pressure sensors set a high-signal or low-signal code; the temperature sensors set a high or low code.

FaultCheckMCZ 11200.03John Deere · Pump pressure and hydraulic oil temperature sensors
Code shows hereFAULTMCZ 11200.03

Where this code shows

Turn the key on and open the monitor's diagnostic/fault screen.

What do these codes mean?

John Deere codes MCZ 11200.03 to MCZ 15011.04 are all about the pump pressure and hydraulic oil temperature sensors. The most common failure type is shorted low (3 of 18); none needs an immediate stop. Start with this check: find which sensor the code names (B35, B36, B37, B38, the fan pump sensor, B40 or B68) and unplug only that one before measuring.

How urgent are they?

None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.

  • Check soon18

What should I check first?

Find which sensor the code names (B35, B36, B37, B38, the fan pump sensor, B40 or B68) and unplug only that one before measuring

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • John Deere MCZ 11200.03Pump 1 delivery pressure sensor (B35) signal high

    The main controller reads the pump 1 delivery pressure sensor (B35) on the pump 1 delivery line as high (above 4.5 V).· Other
    Check soon

    Causes

    • B35 signal wire rubbed bare on the pump 1 side of the harness and touching the 5 V feed wire
    • B35 failed high inside, giving a full-scale signal whatever the pump 1 line pressure is
    • Broken sensor return wire, so the signal floats up toward the supply voltage
    • Oil or water in the B35 plug bridging the signal and supply pins

    Checks

    1. 1Unplug B35 and, key on, measure its harness signal pin; a reading near 5 V means the wire is shorted to the feed or the MCZ pin is faulty
    2. 2Check continuity of the B35 ground wire to the MCZ sensor ground with both ends of the harness disconnected
    3. 3Read the pump 1 delivery pressure on the monitor service screen with the engine stopped; a high value with no pressure is a false reading
    4. 4Pull the B35 plug apart and look for green corrosion, oil or bent pins before spending on a sensor
    5. 5Fit a known good sensor only when the wiring passes and the value stays pegged high
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11200.04Pump 1 delivery pressure sensor (B35) signal low

    The main controller reads the pump 1 delivery pressure sensor (B35) on the pump 1 delivery line as low (below 0.1 V).· Other
    Check soon

    Causes

    • Signal wire from B35 broken inside the sleeve or chafed through at a harness clamp
    • B35 signal wire shorted to the frame near the pump 1 delivery line
    • No 5 V at B35 because of a broken supply wire or a pin pushed back in the plug
    • B35 failed low, outputting close to 0 V at any pressure

    Checks

    1. 1Check for 5 V between the supply and ground pins of the unplugged B35 connector with the key on; none means look back toward the MCZ supply wire
    2. 2Measure resistance from the B35 signal pin to chassis ground with the MCZ end disconnected; a low reading means the wire is grounded
    3. 3Test signal wire continuity from the B35 plug to the MCZ pin while flexing the harness to catch an intermittent break
    4. 4Compare the monitor reading with a gauge on the pump 1 delivery test port while the engine runs
    5. 5Look for a backed-out terminal in the plug and push it home until the lock clicks
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11201.03Fan pump delivery pressure sensor circuit high

    The controller reads the fan pump delivery pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Other
    Check soon

    Causes

    • Signal wire of the fan pump delivery pressure sensor shorted to the 5 V supply or to battery voltage
    • Open return (ground) wire at the fan pump delivery pressure sensor, which lets the signal float high
    • The fan pump delivery pressure sensor failed internally with a stuck high output

    Checks

    1. 1Unplug the fan pump delivery pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
    2. 2Check continuity of the fan pump delivery pressure sensor return wire to the controller sensor ground with both ends disconnected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11201.04Fan pump delivery pressure sensor circuit low

    The controller reads the fan pump delivery pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Other
    Check soon

    Causes

    • Signal wire of the fan pump delivery pressure sensor shorted to ground
    • Broken or unplugged 5 V supply wire to the fan pump delivery pressure sensor
    • The fan pump delivery pressure sensor failed internally with a stuck low output

    Checks

    1. 1With the fan pump delivery pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
    2. 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11202.03Pump 2 delivery pressure sensor (B37) signal high

    The main controller reads the pump 2 delivery pressure sensor (B37) on the pump 2 delivery line as high.· Other
    Check soon

    Causes

    • Short to the 5 V feed in the B37 pigtail, often where it is tie-wrapped against hot or moving parts
    • B37 sensing element gone high, giving full scale whatever pump 2 pressure is
    • Sensor ground wire open, so B37 has no return path and its signal rises
    • Dirty or wet B37 plug leaking between the supply and signal pins

    Checks

    1. 1With B37 unplugged and key on, measure its harness signal pin; supply-level voltage proves a wiring or MCZ fault and not the sensor
    2. 2Test B37 ground-pin continuity to the MCZ; high resistance points to a broken or corroded return wire
    3. 3Watch pump 2 pressure on the monitor with the engine off and the machine at rest; a full-scale value cannot be real pressure
    4. 4If the B35 and B37 connectors match, swap the sensors; the fault following the sensor tells you B37 is bad
    5. 5Look under the connector boot for oil that has wicked up the wires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11202.04Pump 2 delivery pressure sensor (B37) signal low

    The main controller reads the pump 2 delivery pressure sensor (B37) on the pump 2 delivery line as low.· Other
    Check soon

    Causes

    • Signal wire cut or worn through where it crosses a bracket near pump 2
    • B37 signal wire touching the frame and shorted to ground
    • B37 connector supply pin loose or corroded, so the sensor is unpowered
    • B37 failed low inside

    Checks

    1. 1Measure 5 V and ground at the B37 connector with the key on; if the supply is missing, trace it back to the MCZ
    2. 2Meter the signal wire to chassis ground with both ends unplugged to rule out a short to ground
    3. 3Check the signal wire is continuous from B37 to the MCZ while moving the harness near the pump
    4. 4Stall the arm and compare the pump 2 value on the monitor with a gauge at the pump 2 test point
    5. 5Replace B37 only after the circuit proves good and the signal still reads zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11206.03Pump 1 control pressure sensor (B36) signal high

    The main controller reads the pump 1 control pressure sensor (B36) on the pump 1 regulator control line as high.· Other
    Check soon

    Causes

    • B36 shorted to the 5 V supply inside the sensor body or in the cable close to it
    • B36 return wire open, leaving the signal at supply level
    • Corroded B36 plug pins bridging signal to supply

    Checks

    1. 1Disconnect B36 and measure its harness signal pin with the key on; supply-level voltage there means the wire is shorted to the feed
    2. 2Check B36 ground continuity to the MCZ sensor ground to rule out an open return
    3. 3Read the pump 1 control pressure channel on the monitor with the engine stopped; any high value is false
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11206.04Pump 1 control pressure sensor (B36) signal low

    The main controller reads the pump 1 control pressure sensor (B36) on the pump 1 regulator control line as low.· Other
    Check soon

    Causes

    • Open B36 signal wire from a broken core inside the harness sleeve
    • B36 supply wire broken or its pin pushed out of the plug
    • Signal wire pinched against the pump bracket and grounded

    Checks

    1. 1Check for 5 V between the B36 supply and ground pins with the key on and the sensor unplugged
    2. 2Measure the B36 signal wire to ground with the MCZ connector removed; continuity to ground means a pinched wire
    3. 3Do a pin-to-pin continuity check of the signal wire from B36 to the MCZ, flexing the harness gently
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11208.03Pump 2 control pressure sensor circuit high

    The controller reads the pump 2 control pressure sensor (B38) signal above its normal range (the list gives above 4.5 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Other
    Check soon

    Causes

    • Signal wire of the pump 2 control pressure sensor (B38) shorted to the 5 V supply or to battery voltage
    • Open return (ground) wire at the pump 2 control pressure sensor (B38), which lets the signal float high
    • The pump 2 control pressure sensor (B38) failed internally with a stuck high output

    Checks

    1. 1Unplug the pump 2 control pressure sensor (B38) and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
    2. 2Check continuity of the pump 2 control pressure sensor (B38) return wire to the controller sensor ground with both ends disconnected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11208.04Pump 2 control pressure sensor circuit low

    The controller reads the pump 2 control pressure sensor (B38) signal below its normal range (the list gives below 0.1 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Other
    Check soon

    Causes

    • Signal wire of the pump 2 control pressure sensor (B38) shorted to ground
    • Broken or unplugged 5 V supply wire to the pump 2 control pressure sensor (B38)
    • The pump 2 control pressure sensor (B38) failed internally with a stuck low output

    Checks

    1. 1With the pump 2 control pressure sensor (B38) unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
    2. 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11901.03Hydraulic oil temperature sensor (B40) high

    The hydraulic oil temperature sensor (B40) signal is high (above 4.35 V).· Other
    Check soon

    Causes

    • B40 signal wire open between the tank-side sensor and the MCZ, or the plug left unplugged after service
    • B40 thermistor failed open internally
    • B40 signal shorted to the 5 V sensor supply in the harness
    • Corroded B40 connector terminals adding resistance in the signal path

    Checks

    1. 1Unplug B40 and measure the harness signal pin voltage with the key on; near 5 V is what an open sensor gives
    2. 2Measure the B40 resistance and compare it with a similar sensor at the same oil temperature
    3. 3Check wire continuity from the B40 plug to the MCZ pin with both ends unplugged
    4. 4Inspect the B40 connector for water and green corrosion
    5. 5Replace the B40 sensor only after the wiring and connector have been proved good
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11901.04Hydraulic oil temperature sensor (B40) low

    The hydraulic oil temperature sensor (B40) signal is low (below 0.1 V).· Other
    Check soon

    Causes

    • B40 signal wire shorted to ground against the frame
    • B40 thermistor failed shorted internally
    • Water in the B40 connector pulling the signal low
    • Wire rubbed through against a bracket near the tank

    Checks

    1. 1Unplug B40 and see whether the code changes to a high or open condition; if it does, the sensor side is shorted
    2. 2Measure the B40 resistance; a very low reading at normal temperature means the sensor is shorted
    3. 3Check the signal wire for a short to chassis ground with the MCZ end disconnected
    4. 4Inspect the harness routing near the hydraulic tank for rubbing and pinching
    5. 5Replace the B40 sensor only if the wire is clear and the sensor reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11992.03Pump 2 control pressure sensor circuit voltage high

    The controller reads the pump 2 control pressure sensor (B38) signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted high
    Check soon

    Causes

    • Signal wire of the pump 2 control pressure sensor (B38) shorted to the 5 V supply or to battery voltage
    • Open return (ground) wire at the pump 2 control pressure sensor (B38), which lets the signal float high
    • The pump 2 control pressure sensor (B38) failed internally with a stuck high output

    Checks

    1. 1Unplug the pump 2 control pressure sensor (B38) and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
    2. 2Check continuity of the pump 2 control pressure sensor (B38) return wire to the controller sensor ground with both ends disconnected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • John Deere MCZ 11992.04Pump 2 control pressure sensor circuit voltage low

    The controller reads the pump 2 control pressure sensor (B38) signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted low
    Check soon

    Causes

    • Signal wire of the pump 2 control pressure sensor (B38) shorted to ground
    • Broken or unplugged 5 V supply wire to the pump 2 control pressure sensor (B38)
    • The pump 2 control pressure sensor (B38) failed internally with a stuck low output

    Checks

    1. 1With the pump 2 control pressure sensor (B38) unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
    2. 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • John Deere MCZ 11994.03Pump 1 control pressure sensor circuit voltage high

    The controller reads the pump 1 control pressure sensor (B36) signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted high
    Check soon

    Causes

    • Signal wire of the pump 1 control pressure sensor (B36) shorted to the 5 V supply or to battery voltage
    • Open return (ground) wire at the pump 1 control pressure sensor (B36), which lets the signal float high
    • The pump 1 control pressure sensor (B36) failed internally with a stuck high output

    Checks

    1. 1Unplug the pump 1 control pressure sensor (B36) and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
    2. 2Check continuity of the pump 1 control pressure sensor (B36) return wire to the controller sensor ground with both ends disconnected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • John Deere MCZ 11994.04Pump 1 control pressure sensor circuit voltage low

    The controller reads the pump 1 control pressure sensor (B36) signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted low
    Check soon

    Causes

    • Signal wire of the pump 1 control pressure sensor (B36) shorted to ground
    • Broken or unplugged 5 V supply wire to the pump 1 control pressure sensor (B36)
    • The pump 1 control pressure sensor (B36) failed internally with a stuck low output

    Checks

    1. 1With the pump 1 control pressure sensor (B36) unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
    2. 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • John Deere MCZ 15011.03Secondary hydraulic oil temperature sensor (B68) high

    The MCZ reads the secondary hydraulic oil temperature sensor (B68) signal above its normal range, which usually means an open circuit or a short to reference voltage.· Open circuit
    Check soon

    Causes

    • B68 signal wire open between the sensor and the MCZ
    • B68 sensor failed open
    • B68 signal shorted to the 5 V sensor supply

    Checks

    1. 1Unplug B68 and measure the harness signal pin voltage; supply-level voltage points to an open or a short to the feed
    2. 2Measure the B68 resistance and compare it with the same type of sensor at a known temperature
    3. 3Check wire continuity from the B68 plug to the MCZ pin with both ends unplugged
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • John Deere MCZ 15011.04Secondary hydraulic oil temperature sensor (B68) low

    The MCZ reads the secondary hydraulic oil temperature sensor (B68) signal below its normal range, which usually means a short to ground.· Shorted low
    Check soon

    Causes

    • B68 signal shorted to ground
    • B68 sensor failed shorted
    • Water in the B68 connector

    Checks

    1. 1Unplug B68 and see whether the reading changes to a high or open condition on the monitor
    2. 2Measure the B68 resistance with the plug removed; very low at normal temperature means the sensor is shorted
    3. 3Check the signal wire to chassis ground with the MCZ end disconnected
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Find which sensor the code names (B35, B36, B37, B38, the fan pump sensor, B40 or B68) and unplug only that one before measuring
  2. 2With key on and the sensor unplugged, measure its harness signal pin: near 5 V points to a short to the feed, near 0 V to a short to ground or an open signal wire
  3. 3Read the live value on the monitor service screen with the engine stopped; a large pressure with no pump running is a false signal
  4. 4For B40 and B68 measure the sensor resistance cold and compare it with the manual table; open or near zero means a failed element
  5. 5Check the return wire to the MCZ sensor ground for continuity with both ends of the harness disconnected
  6. 6Look at the plug for green corrosion, oil and backed-out terminals before you replace the sensor

Causes

  • Sensor failed inside and sending a fixed full-scale or zero value whatever the pump pressure or oil temperature is
  • Signal wire rubbed through at a pump or tank clamp and touching the 5 V feed (high) or ground (low)
  • Water or oil in the sensor plug bridging two pins, common where pump hoses weep
  • Broken sensor supply or return wire between the plug and the MCZ

Most common here: shorted low (3 of 18)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The pump or the oil temperature reading named in the code is replaced by a default value.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.