John Deere · Main controller (MCZ) - pressure sensors
John Deere Pilot and counterweight pressure sensors fault codes
These sensors report pilot pressure, the small control pressure that tells the valves what the operator wants. One sensor sits on the 5-spool valve block and another on the 4-spool block, and two read the pilot pressure of auxiliary 1 and auxiliary 2 attachment functions.
More about these partsLess
On machines with counterweight removal, a cylinder sensor and a lever sensor serve that function. Each has a high and a low code, and the code names the block or function.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11943.03 to MCZ 11990.04 are all about the pilot and counterweight pressure sensors. The most common failure type is shorted high (4 of 12); none needs an immediate stop. Start with this check: check which valve block or function the code names and unplug that pilot sensor only.
How urgent are they?
None of the 12 codes here means stop now; all 12 can wait until the shift ends, but find the cause before the next one.
- Check soon12
What should I check first?
Check which valve block or function the code names and unplug that pilot sensor only
Shared checks12 of 12
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11943.03Counterweight cylinder pressure sensor circuit voltage high
The controller reads the counterweight cylinder pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits in the counterweight removal cylinder circuit, so the controller cannot tell the counterweight is moving when it is wrong. Only machines fitted with counterweight removal have this sensor, so it can be ignored on others.· Shorted highShorted highCheck soonCauses
- Signal wire of the counterweight cylinder pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the counterweight cylinder pressure sensor, which lets the signal float high
- The counterweight cylinder pressure sensor failed internally with a stuck high output
- Pressure line to the cylinder sensor kinked or its fitting leaking at the rear frame, so the sensor sees no pressure
Checks
- 1Unplug the counterweight cylinder pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the counterweight cylinder pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Operate the counterweight removal while watching the cylinder value; it should follow the cylinder load.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11943.04Counterweight cylinder pressure sensor circuit voltage low
The controller reads the counterweight cylinder pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits in the counterweight removal cylinder circuit, so the controller cannot tell the counterweight is moving when it is wrong. Only machines fitted with counterweight removal have this sensor, so it can be ignored on others.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the counterweight cylinder pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the counterweight cylinder pressure sensor
- The counterweight cylinder pressure sensor failed internally with a stuck low output
- Pressure line to the cylinder sensor kinked or its fitting leaking at the rear frame, so the sensor sees no pressure
Checks
- 1With the counterweight cylinder pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Operate the counterweight removal while watching the cylinder value; it should follow the cylinder load.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11944.03Pilot pressure sensor (5-spool) circuit voltage high
The controller reads the pilot pressure sensor for the 5-spool valve signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits on the 5-spool valve block, so pump demand for that block is calculated from a default. Machines with a 5-spool valve block carry this sensor beside the main control valve.· Shorted highShorted highCheck soonCauses
- Signal wire of the pilot pressure sensor for the 5-spool valve shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the pilot pressure sensor for the 5-spool valve, which lets the signal float high
- The pilot pressure sensor for the 5-spool valve failed internally with a stuck high output
- Pilot port on the 5-spool block blocked by dirt or a loose fitting, giving a flat reading
Checks
- 1Unplug the pilot pressure sensor for the 5-spool valve and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the pilot pressure sensor for the 5-spool valve return wire to the controller sensor ground with both ends disconnected
- 3Compare the live 5-spool pilot value with the 4-spool value at rest; both should be similar and low.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11944.04Pilot pressure sensor (5-spool) circuit voltage low
The controller reads the pilot pressure sensor for the 5-spool valve signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits on the 5-spool valve block, so pump demand for that block is calculated from a default. Machines with a 5-spool valve block carry this sensor beside the main control valve.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the pilot pressure sensor for the 5-spool valve shorted to ground
- Broken or unplugged 5 V supply wire to the pilot pressure sensor for the 5-spool valve
- The pilot pressure sensor for the 5-spool valve failed internally with a stuck low output
- Pilot port on the 5-spool block blocked by dirt or a loose fitting, giving a flat reading
Checks
- 1With the pilot pressure sensor for the 5-spool valve unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Compare the live 5-spool pilot value with the 4-spool value at rest; both should be similar and low.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11945.03Pilot pressure sensor (4-spool) circuit voltage high
The controller reads the pilot pressure sensor for the 4-spool valve signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits on the 4-spool valve block, the counterpart of the 5-spool sensor, so that block loses accurate pilot feedback. Machines with a 4-spool valve block carry this sensor instead, so check which valve block the machine has.· Shorted highShorted highCheck soonCauses
- Signal wire of the pilot pressure sensor for the 4-spool valve shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the pilot pressure sensor for the 4-spool valve, which lets the signal float high
- The pilot pressure sensor for the 4-spool valve failed internally with a stuck high output
- Pilot port on the 4-spool block blocked or leaking, giving a flat or noisy reading
Checks
- 1Unplug the pilot pressure sensor for the 4-spool valve and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the pilot pressure sensor for the 4-spool valve return wire to the controller sensor ground with both ends disconnected
- 3Operate a function on the 4-spool block and watch its pilot value rise.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11945.04Pilot pressure sensor (4-spool) circuit voltage low
The controller reads the pilot pressure sensor for the 4-spool valve signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It sits on the 4-spool valve block, the counterpart of the 5-spool sensor, so that block loses accurate pilot feedback. Machines with a 4-spool valve block carry this sensor instead, so check which valve block the machine has.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the pilot pressure sensor for the 4-spool valve shorted to ground
- Broken or unplugged 5 V supply wire to the pilot pressure sensor for the 4-spool valve
- The pilot pressure sensor for the 4-spool valve failed internally with a stuck low output
- Pilot port on the 4-spool block blocked or leaking, giving a flat or noisy reading
Checks
- 1With the pilot pressure sensor for the 4-spool valve unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Operate a function on the 4-spool block and watch its pilot value rise.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11978.03Auxiliary 2 pilot pressure sensor circuit high input
The controller reads the auxiliary 2 pilot pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reports pilot pressure of the second attachment function, used by tools with a second flow path. Rotators and tilt tools that need a second flow path normally use this second auxiliary function.· OtherOtherCheck soonCauses
- Signal wire of the auxiliary 2 pilot pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the auxiliary 2 pilot pressure sensor, which lets the signal float high
- The auxiliary 2 pilot pressure sensor failed internally with a stuck high output
- Attachment pilot hose for function 2 pinched, leaking or fitted to the wrong port
Checks
- 1Unplug the auxiliary 2 pilot pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the auxiliary 2 pilot pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Select a tool with a second flow path, operate it and watch the auxiliary 2 pilot value change.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11978.04Auxiliary 2 pilot pressure sensor circuit low input
The controller reads the auxiliary 2 pilot pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reports pilot pressure of the second attachment function, used by tools with a second flow path. Rotators and tilt tools that need a second flow path normally use this second auxiliary function.· OtherOtherCheck soonCauses
- Signal wire of the auxiliary 2 pilot pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the auxiliary 2 pilot pressure sensor
- The auxiliary 2 pilot pressure sensor failed internally with a stuck low output
- Attachment pilot hose for function 2 pinched, leaking or fitted to the wrong port
Checks
- 1With the auxiliary 2 pilot pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Select a tool with a second flow path, operate it and watch the auxiliary 2 pilot value change.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11979.03Auxiliary 1 pilot pressure sensor circuit high input
The controller reads the auxiliary 1 pilot pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reports pilot pressure of the first attachment function, so a breaker or crusher may not respond to its lever. Tools such as breakers and shears normally use this first auxiliary function.· OtherOtherCheck soonCauses
- Signal wire of the auxiliary 1 pilot pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the auxiliary 1 pilot pressure sensor, which lets the signal float high
- The auxiliary 1 pilot pressure sensor failed internally with a stuck high output
- Attachment pilot hose for function 1 pinched, leaking or fitted to the wrong port
Checks
- 1Unplug the auxiliary 1 pilot pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the auxiliary 1 pilot pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Operate the attachment lever for function 1 and watch the auxiliary 1 pilot value change.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11979.04Auxiliary 1 pilot pressure sensor circuit low input
The controller reads the auxiliary 1 pilot pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reports pilot pressure of the first attachment function, so a breaker or crusher may not respond to its lever. Tools such as breakers and shears normally use this first auxiliary function.· OtherOtherCheck soonCauses
- Signal wire of the auxiliary 1 pilot pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the auxiliary 1 pilot pressure sensor
- The auxiliary 1 pilot pressure sensor failed internally with a stuck low output
- Attachment pilot hose for function 1 pinched, leaking or fitted to the wrong port
Checks
- 1With the auxiliary 1 pilot pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Operate the attachment lever for function 1 and watch the auxiliary 1 pilot value change.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11990.03Counterweight lever pressure sensor circuit voltage high
The controller reads the counterweight lever pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reads pilot pressure from the counterweight lever, so a wrong value hides the operator request. Counterweight removal is a service function, so this code rarely affects daily digging.· Shorted highShorted highCheck soonCauses
- Signal wire of the counterweight lever pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the counterweight lever pressure sensor, which lets the signal float high
- The counterweight lever pressure sensor failed internally with a stuck high output
- Pilot hose to the lever sensor pinched or leaking, so the lever signal does not rise when moved
Checks
- 1Unplug the counterweight lever pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the counterweight lever pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Move the counterweight lever and watch the lever value change; in neutral it should sit low.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11990.04Counterweight lever pressure sensor circuit voltage low
The controller reads the counterweight lever pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. It reads pilot pressure from the counterweight lever, so a wrong value hides the operator request. Counterweight removal is a service function, so this code rarely affects daily digging.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the counterweight lever pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the counterweight lever pressure sensor
- The counterweight lever pressure sensor failed internally with a stuck low output
- Pilot hose to the lever sensor pinched or leaking, so the lever signal does not rise when moved
Checks
- 1With the counterweight lever pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Move the counterweight lever and watch the lever value change; in neutral it should sit low.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Check which valve block or function the code names and unplug that pilot sensor only
- 2Key on, measure the unplugged signal pin: near 5 V means a short to the feed, near 0 V a short to ground or an open wire
- 3Read the live pilot value on the service screen with the levers in neutral, then while moving the matching lever
- 4Inspect the plug and nearby pilot fittings for oil and corrosion before replacing the sensor
Causes
- Sensor failed inside and giving a fixed signal
- Signal wire rubbed through close to the control valve block or the counterweight mounting
- Plug filled with oil from a weeping pilot fitting
- Broken return wire to the MCZ sensor ground
Most common here: shorted high (4 of 12)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: Pilot dependent control and pump demand lose accuracy for the named valve block, an attachment function may not respond to its lever, or the counterweight removal function may be disabled.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.