EF Logo

Cummins · Air handling

Cummins EGR sensors and ECM temperature fault codes

These pressure sensors measure the pressure drop across the EGR venturi or valve and the EGR outlet pressure. The EGR temperature sensor sits in the recirculated exhaust path, usually after the EGR cooler, and tells the ECM how hot the EGR gas is and whether the cooler is working.

More about these parts

The ECM temperature sensor is built into the control module itself and lets it protect its own electronics from overheating.

FaultCheck2961Cummins · EGR sensors and ECM temperature
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 697 to 7935 are all about the eGR sensors and ECM temperature. The most common failure type is erratic or implausible (5 of 15); none needs an immediate stop. Start with this check: compare the sensor reading at key on, engine off with barometric pressure; it should sit near zero or ambient depending on the sensor.

How urgent are they?

None of the 15 codes here means stop now; all 15 can wait until the shift ends, but find the cause before the next one.

  • Check soon15

What should I check first?

Compare the sensor reading at key on, engine off with barometric pressure; it should sit near zero or ambient depending on the sensor

Shared checks

15 of 15

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Engine ECU temperature sensor circuit2 codes

    • Cummins 697Engine ECU temperature sensor circuit: Voltage high / shorted high

      Same failure as 2375 on the engine ECU temperature sensor circuit: the same fault condition as 2375, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2375, applied to the engine ECU temperature sensor circuit
      • Wiring or connector problem local to the engine ECU temperature sensor circuit

      Checks

      1. 1Check the ECM supply and ground and the mounting heat before replacing the ECM.
      2. 2Work through the checks listed for 2375, starting at the engine ECU temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine ECU temperature sensor circuit - voltage high (shorted to a high source)

    • Cummins 698Engine ECU temperature sensor circuit: Voltage low / shorted low

      Same failure as 2376 on the engine ECU temperature sensor circuit: the same fault condition as 2376, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2376, applied to the engine ECU temperature sensor circuit
      • Wiring or connector problem local to the engine ECU temperature sensor circuit

      Checks

      1. 1Check the ECM supply and ground and the mounting heat before replacing the ECM.
      2. 2Work through the checks listed for 2376, starting at the engine ECU temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine ECU temperature sensor circuit - voltage low (shorted to a low source)

  • Engine ECU temperature1 code

    • Cummins 699Engine ECU temperature: Erratic reading

      Same failure as 1867 on the engine ECU temperature: the same fault condition as 1867, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 1867, applied to the engine ECU temperature
      • Wiring or connector problem local to the engine ECU temperature

      Checks

      1. 1Check the ECM supply and ground and the mounting heat before replacing the ECM.
      2. 2Work through the checks listed for 1867, starting at the engine ECU temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine ECU temperature - data erratic or incorrect

  • EGR delta pressure1 code

    • Cummins 1866EGR delta pressure: Erratic reading

      Same failure as 1867 on the EGR delta pressure: the same fault condition as 1867, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 1867, applied to the EGR delta pressure
      • Wiring or connector problem local to the EGR delta pressure

      Checks

      1. 1Check the two sensing hoses or ports of the delta pressure sensor for soot plugs and the right routing.
      2. 2Work through the checks listed for 1867, starting at the EGR delta pressure and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:EGR delta pressure - data erratic or incorrect

  • EGR temperature1 code

    • Cummins 1867EGR temperature: Erratic reading

      The ECM judges the EGR temperature to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact on the EGR temperature
      • Part ageing or failing and giving unstable output
      • Electrical noise from a poorly routed wire or a bad ground

      Checks

      1. 1Watch the EGR temperature live in INSITE and wiggle the harness and connector to catch dropouts
      2. 2Compare the EGR temperature with a related reading to decide which one is wrong
      3. 3Check the connector for moisture and corrosion and the ground connection for tightness
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:EGR temperature - data erratic or incorrect

  • EGR valve delta pressure sensor circuit2 codes

    • Cummins 2273EGR valve delta pressure sensor circuit: Voltage high / shorted high

      Same failure as 2375 on the EGR valve delta pressure sensor circuit: the same fault condition as 2375, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2375, applied to the EGR valve delta pressure sensor circuit
      • Wiring or connector problem local to the EGR valve delta pressure sensor circuit

      Checks

      1. 1Check the two sensing hoses or ports of the delta pressure sensor for soot plugs and the right routing.
      2. 2Work through the checks listed for 2375, starting at the EGR valve delta pressure sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:EGR valve delta pressure sensor circuit - voltage high (shorted to a high source)

    • Cummins 2274EGR valve delta pressure sensor circuit: Voltage low / shorted low

      Same failure as 2376 on the EGR valve delta pressure sensor circuit: the same fault condition as 2376, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2376, applied to the EGR valve delta pressure sensor circuit
      • Wiring or connector problem local to the EGR valve delta pressure sensor circuit

      Checks

      1. 1Check the two sensing hoses or ports of the delta pressure sensor for soot plugs and the right routing.
      2. 2Work through the checks listed for 2376, starting at the EGR valve delta pressure sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:EGR valve delta pressure sensor circuit - voltage low (shorted to a low source)

  • EGR temperature sensor circuit2 codes

    • Cummins 2375EGR temperature sensor circuit: Voltage high / shorted high

      The ECM reads the EGR temperature sensor circuit above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the EGR temperature sensor circuit
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the EGR temperature sensor circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the EGR temperature sensor circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the EGR temperature sensor circuit back to the ECM
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:EGR temperature sensor circuit - voltage high (shorted to a high source)

    • Cummins 2376EGR temperature sensor circuit: Voltage low / shorted low

      The ECM reads the EGR temperature sensor circuit below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the EGR temperature sensor circuit rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the EGR temperature sensor circuit connector

      Checks

      1. 1Key on, unplug the EGR temperature sensor circuit and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the EGR temperature sensor circuit signal wire to ground with the ECM unplugged to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:EGR temperature sensor circuit - voltage low (shorted to a low source)

  • Engine EGR outlet pressure sensor circuit2 codes

    • Cummins 3136Engine EGR outlet pressure sensor circuit: Voltage high / shorted high

      Same failure as 2375 on the engine EGR outlet pressure sensor circuit: the same fault condition as 2375, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2375, applied to the engine EGR outlet pressure sensor circuit
      • Wiring or connector problem local to the engine EGR outlet pressure sensor circuit

      Checks

      1. 1Check the sensing port of the EGR outlet pressure sensor for a soot blockage.
      2. 2Work through the checks listed for 2375, starting at the engine EGR outlet pressure sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine EGR outlet pressure sensor circuit - voltage high (shorted to a high source)

    • Cummins 3137Engine EGR outlet pressure sensor circuit: Voltage low / shorted low

      Same failure as 2376 on the engine EGR outlet pressure sensor circuit: the same fault condition as 2376, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2376, applied to the engine EGR outlet pressure sensor circuit
      • Wiring or connector problem local to the engine EGR outlet pressure sensor circuit

      Checks

      1. 1Check the sensing port of the EGR outlet pressure sensor for a soot blockage.
      2. 2Work through the checks listed for 2376, starting at the engine EGR outlet pressure sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine EGR outlet pressure sensor circuit - voltage low (shorted to a low source)

  • Engine EGR outlet pressure1 code

    • Cummins 3138Engine EGR outlet pressure: Erratic reading

      Same failure as 1867 on the engine EGR outlet pressure: the same fault condition as 1867, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 1867, applied to the engine EGR outlet pressure
      • Wiring or connector problem local to the engine EGR outlet pressure

      Checks

      1. 1Check the sensing port of the EGR outlet pressure sensor for a soot blockage.
      2. 2Work through the checks listed for 1867, starting at the engine EGR outlet pressure and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine EGR outlet pressure - data erratic or incorrect

  • Engine EGR 1 temperature1 code

    • Cummins 7935Engine EGR 1 temperature: Abnormal rate of change

      The engine EGR 1 temperature changed faster than it physically could, so the ECM treats the reading as a sensor or wiring problem and not as a real change.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the harness or connector of the engine EGR 1 temperature
      • Failing part giving unstable output
      • Poor ground or noisy supply feeding the circuit

      Checks

      1. 1Log the engine EGR 1 temperature while moving the harness and connector, and look for steps instead of smooth changes
      2. 2Inspect the engine EGR 1 temperature connector for water, corrosion and loose pins
      3. 3Check the supply and ground at the engine EGR 1 temperature while the engine runs
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Other codes2 codes

    • Cummins 2961EGR temperature high· least severe

      The EGR gas temperature after the cooler is above the first limit.· Other
      Check soon

      Causes

      • EGR cooler fouled with soot inside
      • Low coolant flow through the EGR cooler
      • Coolant level low or air trapped
      • EGR temperature sensor reading high

      Checks

      1. 1Check the coolant level and for air in the system
      2. 2Check the cooling system flow and the thermostat
      3. 3Compare the EGR temperature with the coolant temperature under load
      4. 4Check the EGR cooler for soot blockage or leakage by comparing the temperature before and after the cooler
      5. 5Check the EGR temperature sensor circuit if the temperature reading does not agree with the others
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:EGR temperature high - least severe

      Full page for 2961
    • Cummins 2962EGR temperature high· moderately severe

      Same failure as 2961 on the EGR temperature high: the same fault condition as 2961, reported for this part.· Lost message
      Check soon

      Causes

      • Same causes as 2961, applied to the EGR temperature high
      • Wiring or connector problem local to the EGR temperature high

      Checks

      1. 1Check the EGR cooler outlet area and its sensor connector for heat damage.
      2. 2Work through the checks listed for 2961, starting at the EGR temperature high and its connector
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

      Source wording:EGR temperature high - moderately severe

Shared checks

Checks, in order

  1. 1Compare the sensor reading at key on, engine off with barometric pressure; it should sit near zero or ambient depending on the sensor
  2. 2Read the EGR temperature and ECM temperature at key on, engine off and compare them with ambient on a cold engine
  3. 3Remove the sensor hoses or ports and check for soot plugging
  4. 4Unplug the EGR sensor and check the connector, reference and signal wires for opens and shorts
  5. 5Check reference, return and signal at the harness with the sensor unplugged
  6. 6Inspect the EGR cooler and EGR passages for restriction, coolant leaks and soot build-up
  7. 7Inspect the connector for corrosion and bent pins

Causes

  • Sensor pressure ports blocked with soot or condensate
  • Heat-damaged or corroded harness at the EGR sensor connector
  • Sensor harness damaged by heat or chafing
  • Failed EGR temperature sensor or an EGR cooler that is clogged or leaking

Most common here: erratic or implausible (5 of 15)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: EGR flow cannot be measured, so the ECM falls back to a fixed EGR rate or shuts EGR off, which can bring a derate and an emissions lamp.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.