EF Logo

Cummins · Aftertreatment

Cummins DPF pressure sensors and DPF system fault codes

The DPF differential pressure sensor measures the pressure drop across the diesel particulate filter through two sensing hoses, and the DPF outlet pressure sensor measures exhaust pressure after the filter. The ECM uses them to estimate soot load, decide when to regenerate and detect a blocked or damaged filter.

More about these parts

These codes cover the diesel particulate filter as a system: whether it is present, whether it is behaving as expected and whether service is needed.

FaultCheck1879Cummins · DPF pressure sensors and DPF system
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 1879 to 6786 are all about the dPF pressure sensors and DPF system. The most common failure type is erratic or implausible (6 of 20); 2 need an immediate stop. Start with this check: read the differential and outlet pressure at key on, engine off: both should be near zero.

How urgent are they?

2 of 20 codes here mean stop now; 15 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Stop now2
  • Check soon15
  • Info3

What should I check first?

Read the differential and outlet pressure at key on, engine off: both should be near zero

Shared checks

20 of 20

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DPF differential pressure2 codes

    • Cummins 1883DPF differential pressure: Erratic reading

      The ECM judges the DPF differential pressure to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DPF differential pressure live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF differential pressure - data erratic or incorrect

    • Cummins 5715DPF differential pressure: Abnormal rate of change

      The DPF differential pressure reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the DPF differential pressure reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • DPF system6 codes

    • Cummins 1981DPF system: Above normal· least severe

      The DPF system is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DPF system with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF system - above normal - least severe

    • Cummins 2692DPF system: Erratic reading

      The ECM judges the DPF system to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DPF system live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF system - data erratic or incorrect

    • Cummins 3168DPF system: Above normal· moderately severe

      The DPF system is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DPF system with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF system - above normal - moderately severe

    • Cummins 3245DPF system: Mechanical fault or not responding

      The ECM commands the DPF system but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the DPF system in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 4584DPF system: Special instructions

      The ECM sets a special-instruction fault for the DPF system.· Other
      Info

      Causes

      • A condition that requires a guided repair or verification step
      • A related fault that set first

      Checks

      1. 1Open the fault in INSITE and follow its troubleshooting steps
      2. 2Clear all related codes first and recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6265DPF system: Mechanical fault or not responding

      The ECM commands the DPF system but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the DPF system in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Engine DPF intake pressure1 code

    • Cummins 2754Engine DPF intake pressure: Above normal· moderately severe

      The engine DPF intake pressure is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live engine DPF intake pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine DPF intake pressure - above normal - moderately severe

  • DPF outlet pressure sensor circuit2 codes

    • Cummins 3133DPF outlet pressure sensor circuit: Voltage high / shorted high

      The ECM sees the DPF outlet pressure sensor signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live DPF outlet pressure sensor circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DPF outlet pressure sensor circuit - voltage high (shorted to a high source)

    • Cummins 3134DPF outlet pressure sensor circuit: Voltage low / shorted low

      The ECM sees the DPF outlet pressure sensor signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live DPF outlet pressure sensor circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DPF outlet pressure sensor circuit - voltage low (shorted to a low source)

  • DPF outlet pressure2 codes

    • Cummins 3135DPF outlet pressure: Erratic reading

      The ECM judges the DPF outlet pressure to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DPF outlet pressure live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet pressure - data erratic or incorrect

    • Cummins 5716DPF outlet pressure: Abnormal rate of change

      The DPF outlet pressure reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the DPF outlet pressure reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • DPF outlet pressure sensor1 code

    • Cummins 6786DPF outlet pressure sensor: Reading drifted high

      The DPF outlet pressure sensor reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the DPF outlet pressure sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet pressure sensor - data drifted high

  • Other codes6 codes

    • Cummins 1879DPF differential pressure sensor signal voltage high

      The ECM sees the DPF differential pressure sensor signal above its normal voltage band.· Shorted high
      Check soon

      Causes

      • DPF pressure sensor signal shorted to the reference line in the harness
      • Open return wire at the sensor connector
      • Differential pressure sensor failed high after water or soot got in
      • Pressure hoses swapped on the sensor ports giving a high reading

      Checks

      1. 1Key on, engine off: differential pressure should read near zero; a high reading confirms the sensor circuit
      2. 2Unplug the sensor and measure reference and return at the harness
      3. 3Disconnect the hoses at the sensor to see whether the reading drops
      4. 4Probe the signal wire for a short to a supply
      5. 5Replace the sensor only after the hoses and harness pass
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 1881DPF differential pressure sensor signal voltage low

      The ECM sees the DPF differential pressure sensor signal below its normal voltage band.· Shorted low
      Check soon

      Causes

      • DPF pressure sensor signal shorted to ground in the harness
      • Open reference wire at the sensor connector
      • Sensor failed low
      • Water in the connector

      Checks

      1. 1Key on, engine off: a reading below zero on the scale shows a low-voltage fault
      2. 2Measure the 5 V reference at the unplugged sensor
      3. 3Test the signal wire for a short to ground with the ECM plug removed
      4. 4Look for water in the connector and the hoses
      5. 5Replace the sensor if the supply and signal wires are good
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 1921DPF differential pressure high· moderately severe

      The pressure drop across the diesel particulate filter is above the second limit, which means the filter is loaded with soot.· Other
      Check soon

      Causes

      • Particulate filter full of soot
      • Regenerations being interrupted or inhibited
      • DPF pressure lines plugged or swapped
      • Engine making excess soot from a fuel, air or EGR problem

      Checks

      1. 1Start a parked regeneration with INSITE if the machine allows it
      2. 2Check the DPF pressure sensor lines for blockage
      3. 3Look for engine faults that cause excess soot, such as injector, EGR or turbo problems
      4. 4Check the DPF inlet and outlet temperatures during regeneration
      5. 5Remove and clean or replace the filter if it will not clear
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DPF differential pressure high - moderately severe

      Full page for 1921
    • Cummins 1922DPF differential pressure high· most severe

      The soot loading in the DPF is at the highest level.· Other
      Stop now

      Causes

      • DPF very full of soot
      • Regenerations repeatedly aborted
      • Pressure sensor line problem

      Checks

      1. 1Stop the engine and look for a regeneration request
      2. 2Perform a service regeneration with INSITE if the filter is not completely blocked
      3. 3Check the pressure sensor and its lines for blockage and confirm the readings
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DPF differential pressure high - most severe

    • Cummins 1993Aftertreatment diesel particulate filter missing

      The ECM thinks there is no particulate filter in the exhaust, which usually means the filter was removed or the differential pressure reading is wrong.· Other
      Stop now

      Causes

      • Particulate filter removed or hollow
      • Pressure sensor failure making it look missing
      • Pressure lines disconnected

      Checks

      1. 1Look at the exhaust to see that the DPF is fitted
      2. 2Check the differential pressure lines are connected and not cut or swapped
      3. 3Check the pressure sensor values with the engine off and running for a plausible change
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 2639DPF differential pressure high· least severe

      The pressure across the particulate filter is above the first limit, so soot is building up.· Other
      Info

      Causes

      • Soot building up in the filter
      • Short-trip or low-speed use stopping the passive regeneration
      • Pressure lines partly blocked

      Checks

      1. 1Drive at highway speed for a regeneration or start a parked one
      2. 2Check the regeneration inhibit switch and its status
      3. 3Check the DPF pressure lines for blockage, kinks or water that fakes a high pressure reading
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DPF differential pressure high - least severe

Shared checks

Checks, in order

  1. 1Read the differential and outlet pressure at key on, engine off: both should be near zero
  2. 2Check the DPF is fitted and is the correct part for the engine
  3. 3Inspect the sensing hoses and ports for soot plugs, cracks, kinks and correct routing
  4. 4Check the DPF differential pressure sensor and hoses first
  5. 5Unplug the sensor and check reference, return and signal for the correct 5 V and continuity
  6. 6Review the regeneration history and the soot and ash load
  7. 7Blow the hoses through or clear the ports, then retest the live reading

Causes

  • Sensing hose or port blocked, split, kinked or connected to the wrong side
  • DPF loaded or cracked
  • Real soot or ash blockage in the filter or a damaged, melted filter
  • DPF removed or replaced with the wrong part

Most common here: erratic or implausible (6 of 20)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: Regeneration warnings, a derate if the filter looks blocked, and possibly a lamp with frequent regenerations.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.