EF Logo

Cummins · Aftertreatment

Cummins Aftertreatment temperature modules, DOC condition and oxygen sensors fault codes

A small module collects the exhaust temperature sensors for the DPF or SCR area and sends them to the ECM over the data link. The diesel oxidation catalyst converts hydrocarbons and heats the exhaust for regeneration.

More about these parts

Oxygen sensors in the aftertreatment system report oxygen content in the exhaust, usually integrated with the NOx sensors.

FaultInfo1664Cummins · DOC missing
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 1664 to 8595 are all about the aftertreatment temperature modules, DOC condition and oxygen sensors. The most common failure type is erratic or implausible (8 of 23); none needs an immediate stop. Start with this check: check the module power and ground at its connector.

How urgent are they?

None of the 23 codes here means stop now; 19 can wait until the shift ends, but find the cause before the next one; 4 are information only.

  • Check soon19
  • Info4

What should I check first?

Check the module power and ground at its connector

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DOC missing1 code

    • Cummins 1664DOC missing: Condition exists

      The ECM sets this code when it recognises a defined condition for the DOC missing.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Aftertreatment outlet oxygen sensor1 code

    • Cummins 1864Aftertreatment outlet oxygen sensor: Erratic reading

      The ECM judges the aftertreatment outlet oxygen sensor to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the aftertreatment outlet oxygen sensor live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment outlet oxygen sensor - data erratic or incorrect

  • DPF temperature sensor module7 codes

    • Cummins 4151DPF temperature sensor module: Abnormal update rate

      The ECM is not receiving fresh data for the DPF temperature sensor module at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4158DPF temperature sensor module: Bad device or component

      The ECM judges the DPF temperature sensor module to be an internal failure of the device or module.· Part or controller
      Check soon

      Causes

      • Internal failure of the device
      • Supply or ground problem causing it to reset
      • Corrupt software

      Checks

      1. 1Check supply and ground at the device before condemning it
      2. 2Reflash with the correct software where possible
      3. 3Replace the device if the fault persists after the supply tests are good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 4161DPF temperature sensor module: Voltage high / shorted high

      The ECM sees the DPF temperature sensor module signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live DPF temperature sensor module value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DPF temperature sensor module - voltage high (shorted to a high source)

    • Cummins 4162DPF temperature sensor module: Voltage low / shorted low

      The ECM sees the DPF temperature sensor module signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live DPF temperature sensor module value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DPF temperature sensor module - voltage low (shorted to a low source)

    • Cummins 4163DPF temperature sensor module: Above normal· moderately severe

      The DPF temperature sensor module is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DPF temperature sensor module with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF temperature sensor module - above normal - moderately severe

    • Cummins 4259DPF temperature sensor module: Root cause not known

      The ECM detects a problem with the DPF temperature sensor module but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 8595DPF temperature sensor module: Erratic reading

      The ECM judges the DPF temperature sensor module to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DPF temperature sensor module live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF temperature sensor module - data erratic or incorrect

  • SCR temperature sensor module6 codes

    • Cummins 4152SCR temperature sensor module: Abnormal update rate

      The ECM is not receiving fresh data for the SCR temperature sensor module at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4159SCR temperature sensor module: Bad device or component

      The ECM judges the SCR temperature sensor module to be an internal failure of the device or module.· Part or controller
      Check soon

      Causes

      • Internal failure of the device
      • Supply or ground problem causing it to reset
      • Corrupt software

      Checks

      1. 1Check supply and ground at the device before condemning it
      2. 2Reflash with the correct software where possible
      3. 3Replace the device if the fault persists after the supply tests are good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 4164SCR temperature sensor module: Voltage high / shorted high

      The ECM sees the SCR temperature sensor module signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live SCR temperature sensor module value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:SCR temperature sensor module - voltage high (shorted to a high source)

    • Cummins 4165SCR temperature sensor module: Voltage low / shorted low

      The ECM sees the SCR temperature sensor module signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live SCR temperature sensor module value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:SCR temperature sensor module - voltage low (shorted to a low source)

    • Cummins 4166SCR temperature sensor module: Above normal· moderately severe

      The SCR temperature sensor module is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live SCR temperature sensor module with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:SCR temperature sensor module - above normal - moderately severe

    • Cummins 4261SCR temperature sensor module: Root cause not known

      The ECM detects a problem with the SCR temperature sensor module but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DOC conversion efficiency1 code

    • Cummins 4282DOC conversion efficiency: Condition exists

      The ECM sets this code when it recognises a defined condition for the DOC conversion efficiency.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Aftertreatment intake oxygen sensor2 codes

    • Cummins 4747Aftertreatment intake oxygen sensor: Reading drifted high

      The aftertreatment intake oxygen sensor reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the aftertreatment intake oxygen sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment intake oxygen sensor - data drifted high

    • Cummins 4748Aftertreatment intake oxygen sensor: Reading drifted low

      The aftertreatment intake oxygen sensor reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the aftertreatment intake oxygen sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment intake oxygen sensor - data drifted low

  • Aftertreatment outlet oxygen2 codes

    • Cummins 4749Aftertreatment outlet oxygen: Reading drifted high

      The aftertreatment outlet oxygen reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the aftertreatment outlet oxygen with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment outlet oxygen - data drifted high

    • Cummins 4751Aftertreatment outlet oxygen: Reading drifted low

      The aftertreatment outlet oxygen reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the aftertreatment outlet oxygen with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment outlet oxygen - data drifted low

  • Other codes3 codes

    • Cummins 1691DOC conversion efficiency low· moderately severe

      The oxidation catalyst efficiency is below the second limit.· Other
      Check soon

      Causes

      • Catalyst deactivated by contamination
      • Aftertreatment fuel doser failure
      • Temperature sensor reading wrong

      Checks

      1. 1Check the temperature sensors before and after the DOC
      2. 2Check the doser or in-cylinder injection used for the regeneration for correct operation
      3. 3Check for exhaust leaks before the DOC, which lower the temperature at the catalyst
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DOC conversion efficiency low - moderately severe

    • Cummins 2637DOC face plugged

      The diesel oxidation catalyst inlet face seems plugged, so exhaust flow and heat generation are restricted.· Real condition
      Check soon

      Causes

      • Catalyst face blocked by soot or oil ash
      • Engine burning oil or making heavy smoke
      • Fuel contamination

      Checks

      1. 1Look for the cause of heavy soot or oil, such as turbo seal leaks
      2. 2Check the DOC for blockage per the service procedure
      3. 3Check the DPF pressure sensors and their lines for readings that do not match the physical state
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

    • Cummins 2638DOC conversion efficiency low· least severe

      The oxidation catalyst is not creating as much heat from the injected fuel as expected, so the regeneration may be weak.· Other
      Check soon

      Causes

      • Catalyst worn or contaminated
      • Doser or injector fault
      • DOC temperature sensor reading wrong

      Checks

      1. 1Check the DOC temperatures during a regeneration
      2. 2Check the doser or in-cylinder injection used for the regeneration for correct operation
      3. 3Check the temperature sensors before and after the DOC for drift against each other
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DOC conversion efficiency low - least severe

Shared checks

Checks, in order

  1. 1Check the module power and ground at its connector
  2. 2Check both DOC temperature sensors read sensibly before judging the catalyst
  3. 3Check the sensor connector and wiring for damage
  4. 4Inspect the module connector and harness for heat damage
  5. 5Inspect the DOC face for soot or oil and look for physical damage
  6. 6Look for data link faults between the module and the ECM
  7. 7Confirm the catalyst fitted is the correct part number

Causes

  • Module power or ground fault
  • Catalyst fouled with soot, oil or fuel
  • Sensor aged or drifted
  • Module wiring or connector damage

Most common here: erratic or implausible (8 of 23)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: Several exhaust temperature readings are lost at once, so regeneration may be disabled.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.