EF Logo

Cummins · Aftertreatment

Cummins Intake and outlet NOx sensors fault codes

Two NOx sensors bracket the SCR catalyst. The intake sensor measures NOx entering the catalyst so the ECM can calculate how much DEF to inject, and the outlet sensor measures NOx leaving it so the ECM can check that the SCR is converting NOx and trim dosing.

More about these parts

Each sensor has its own control module, heater and power supply.

FaultCheck2771Cummins · Aftertreatment outlet NOx sensor
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 1694 to 6463 are all about the intake and outlet NOx sensors. Most are erratic or implausible faults; none needs an immediate stop. Start with this check: check the supply voltage and ground at the sensor connector with the key on.

How urgent are they?

None of the 26 codes here means stop now; 23 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon23
  • Info3

What should I check first?

Check the supply voltage and ground at the sensor connector with the key on

Shared checks

26 of 26

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Aftertreatment outlet NOx sensor2 codes

    • Cummins 1694Aftertreatment outlet NOx sensor: Erratic reading

      The outlet NOx sensor reading does not make sense compared with the inlet value or the engine state.· Erratic or implausible
      Check soon

      Causes

      • Outlet NOx sensor contaminated or failing
      • Exhaust leak near the sensor
      • Sensor connector corroded

      Checks

      1. 1Read the outlet NOx value in INSITE after a warm-up
      2. 2Check the exhaust for leaks upstream of the sensor
      3. 3Inspect the NOx sensor connector and supply voltage
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Aftertreatment outlet NOx sensor - data erratic

    • Cummins 2771Aftertreatment outlet NOx sensor: Abnormal update rate

      The ECM does not get the outlet NOx sensor messages at the expected rate over the CAN link.· Lost message
      Check soon

      Causes

      • Outlet NOx sensor connector corroded or loose in the exhaust area
      • Outlet NOx sensor failed internally and dropping messages
      • NOx sensor supply voltage low because of a poor connection or fuse
      • CAN wiring to the NOx sensor chafed or open

      Checks

      1. 1Read the NOx sensor values in INSITE and see whether the outlet reading appears and updates
      2. 2Check the outlet NOx sensor connector, which is by the exhaust, for water and green corrosion
      3. 3Measure sensor supply voltage at the connector with the key on
      4. 4Inspect the CAN wires between the sensor and the control module for rub-through
      5. 5Replace the sensor only if wiring and supply are good and the message still drops out
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Aftertreatment intake NOx sensor circuit1 code

    • Cummins 1885Aftertreatment intake NOx sensor circuit: Voltage low

      The inlet NOx sensor circuit reads low, usually from a power loss or a shorted wire.· Shorted low
      Check soon

      Causes

      • Sensor supply interrupted
      • Shorted wire
      • Sensor failed

      Checks

      1. 1Check the supply and ground at the NOx sensor connector
      2. 2Inspect the harness for heat damage near the exhaust
      3. 3Check the NOx sensor module connections and ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Aftertreatment outlet NOx sensor circuit1 code

    • Cummins 1887Aftertreatment outlet NOx sensor circuit: Voltage low

      The outlet NOx sensor circuit is reading low voltage.· Shorted low
      Check soon

      Causes

      • NOx sensor supply fuse or connector
      • Shorted harness
      • Sensor failed

      Checks

      1. 1Check the NOx sensor supply voltage at the connector
      2. 2Inspect the NOx sensor connector for corrosion and moisture
      3. 3Test the NOx sensor harness for a short to ground with the sensor unplugged
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Intake NOx sensor6 codes

    • Cummins 3228Intake NOx sensor: Erratic reading

      The ECM judges the intake NOx sensor to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the intake NOx sensor live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx sensor - data erratic or incorrect

    • Cummins 3232Intake NOx sensor: Abnormal update rate

      The ECM is not receiving fresh data for the intake NOx sensor at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3725Intake NOx sensor: Abnormal rate of change

      The intake NOx sensor reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the intake NOx sensor reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3748Intake NOx sensor: Reading drifted high

      The intake NOx sensor reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the intake NOx sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx sensor - data drifted high

    • Cummins 6458Intake NOx sensor: Reading drifted high

      The intake NOx sensor reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the intake NOx sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx sensor - data drifted high

    • Cummins 6459Intake NOx sensor: Reading drifted low

      The intake NOx sensor reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the intake NOx sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx sensor - data drifted low

  • Intake NOx sensor circuit1 code

    • Cummins 3446Intake NOx sensor circuit: Voltage low / shorted low

      The ECM sees the intake NOx sensor signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live intake NOx sensor circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Intake NOx sensor circuit - voltage low (shorted to a low source)

  • Outlet NOx sensor circuit1 code

    • Cummins 3545Outlet NOx sensor circuit: Abnormal rate of change

      The outlet NOx sensor circuit reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the outlet NOx sensor circuit reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Outlet NOx sensor heater1 code

    • Cummins 3583Outlet NOx sensor heater: Abnormal rate of change

      The outlet NOx sensor heater reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the outlet NOx sensor heater reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Intake NOx sensor heater1 code

    • Cummins 3649Intake NOx sensor heater: Abnormal rate of change

      The intake NOx sensor heater reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the intake NOx sensor heater reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Outlet NOx sensor power supply1 code

    • Cummins 3681Outlet NOx sensor power supply: Erratic reading

      The ECM judges the outlet NOx sensor power supply to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the outlet NOx sensor power supply live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Outlet NOx sensor power supply - data erratic or incorrect

  • Intake NOx sensor power supply1 code

    • Cummins 3682Intake NOx sensor power supply: Erratic reading

      The ECM judges the intake NOx sensor power supply to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the intake NOx sensor power supply live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx sensor power supply - data erratic or incorrect

  • Intake NOx3 codes

    • Cummins 3718Intake NOx: Out of calibration

      The ECM reports the intake NOx as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controller
      Check soon

      Causes

      • Sensor or device out of tolerance
      • Wrong calibration or learn data after a repair

      Checks

      1. 1Check whether a learn or calibration procedure is needed after the last repair
      2. 2Compare with a related sensor and replace the part if the offset is real
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 3726Intake NOx: Above normal· moderately severe

      The intake NOx is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live intake NOx with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Intake NOx - above normal - moderately severe

    • Cummins 6461Intake NOx: Erratic reading

      The ECM judges the intake NOx to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the intake NOx live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Intake NOx - data erratic or incorrect

  • Outlet NOx sensor3 codes

    • Cummins 3749Outlet NOx sensor: Reading drifted high

      The outlet NOx sensor reading has drifted high compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the outlet NOx sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Outlet NOx sensor - data drifted high

    • Cummins 5689Outlet NOx sensor: Root cause not known

      The ECM detects a problem with the outlet NOx sensor but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6463Outlet NOx sensor: Reading drifted low

      The outlet NOx sensor reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the outlet NOx sensor with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Outlet NOx sensor - data drifted low

  • Outlet NOx sensor closed loop operation1 code

    • Cummins 4452Outlet NOx sensor closed loop operation: Condition exists

      The ECM sets this code when it recognises a defined condition for the outlet NOx sensor closed loop operation.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Outlet NOx sensor self-diagnosis1 code

    • Cummins 5838Outlet NOx sensor self-diagnosis: Abnormal rate of change

      The outlet NOx sensor self-diagnosis reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the outlet NOx sensor self-diagnosis reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Outlet NOx sensor self-diagnosis trigger1 code

    • Cummins 6246Outlet NOx sensor self-diagnosis trigger: Root cause not known

      The ECM detects a problem with the outlet NOx sensor self-diagnosis trigger but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Other codes1 code

    • Cummins 3717Aftertreatment outlet NOx sensor out of calibration

      The outlet NOx sensor output is outside its calibration limits when checked against the expected zero point, so the ECM does not trust the reading.· Part or controller
      Check soon

      Causes

      • NOx sensor aged or contaminated
      • Exhaust leak near the sensor
      • Water damage in the sensor module

      Checks

      1. 1Read the NOx reading with the engine off and compare with the expected near-zero value
      2. 2Check the exhaust for leaks upstream of the outlet NOx sensor that dilute the sample
      3. 3Inspect the NOx sensor connector for moisture and corrosion
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

Shared checks

Checks, in order

  1. 1Check the supply voltage and ground at the sensor connector with the key on
  2. 2Inspect the sensor connector and harness for corrosion, heat damage and chafing
  3. 3Check the exhaust for leaks upstream of the sensor
  4. 4Read the sensor value and status live and look for dropouts or readings stuck out of range
  5. 5Compare the intake and outlet sensors with the engine at a steady load to see which one disagrees
  6. 6Check the DEF quality, dosing and SCR condition if the outlet NOx reads higher than expected

Causes

  • Sensor supply or ground fault, or damaged connector
  • Sensor with a failed element or heater
  • Exhaust leak near the sensor changing the reading
  • DEF system or catalyst problem that makes the real NOx value wrong

Most codes here: erratic or implausible (16 of 26)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A lamp, possible DEF dosing problems and, if the fault persists, an emissions derate or inducement.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.