Thermistor-type exhaust temperature sensors sit before and after the diesel oxidation catalyst (DOC) and at the DPF inlet and outlet. The ECM uses them to see whether the DOC is heating the exhaust, to control regeneration and to protect the filter from over-temperature.

FaultCheck3251Cummins · DOC intake temperature
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 3251 to 7894 are all about the dOC and DPF exhaust temperature sensors. The most common failure type is erratic or implausible (11 of 25); 2 need an immediate stop. Start with this check: read the DOC and DPF temperatures live with the engine cold: all four should match ambient and each other.

How urgent are they?

2 of 25 codes here mean stop now; 21 can wait until the shift ends, but find the cause before the next one; 2 are information only.

  • Stop now2
  • Check soon21
  • Info2

What should I check first?

Read the DOC and DPF temperatures live with the engine cold: all four should match ambient and each other

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DOC intake temperature2 codes

    • Cummins 3251DOC intake temperature: Above normal· moderately severe

      Same failure as 3311 on the DOC intake temperature: the same fault condition as 3311, reported for this part.· Real condition
      Check soon

      Causes

      • Same causes as 3311, applied to the DOC intake temperature
      • Wiring or connector problem local to the DOC intake temperature

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 3311, starting at the DOC intake temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DOC intake temperature - above normal - moderately severe

    • Cummins 3315DOC intake temperature: Erratic reading

      Same failure as 3318 on the DOC intake temperature: the same fault condition as 3318, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 3318, applied to the DOC intake temperature
      • Wiring or connector problem local to the DOC intake temperature

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 3318, starting at the DOC intake temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DOC intake temperature - data erratic or incorrect

  • DPF intake temperature4 codes

    • Cummins 3253DPF intake temperature: Above normal· moderately severe

      Same failure as 3311 on the DPF intake temperature: the same fault condition as 3311, reported for this part.· Real condition
      Check soon

      Causes

      • Same causes as 3311, applied to the DPF intake temperature
      • Wiring or connector problem local to the DPF intake temperature

      Checks

      1. 1Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      2. 2Work through the checks listed for 3311, starting at the DPF intake temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF intake temperature - above normal - moderately severe

    • Cummins 3254DPF intake temperature: Above normal· least severe

      Same failure as 3311 on the DPF intake temperature: the same fault condition as 3311, reported for this part.· Real condition
      Info

      Causes

      • Same causes as 3311, applied to the DPF intake temperature
      • Wiring or connector problem local to the DPF intake temperature

      Checks

      1. 1Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      2. 2Work through the checks listed for 3311, starting at the DPF intake temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF intake temperature - above normal - least severe

    • Cummins 3311DPF intake temperature: Above normal· most severe

      The DPF intake temperature is above its normal range (severity: most severe).· Real condition
      Stop now

      Causes

      • A real over-limit condition in the system the DPF intake temperature measures
      • Sensor or circuit reading high from a wiring fault
      • A cooling, flow or restriction problem upstream that drives the value up

      Checks

      1. 1Confirm the real condition with a gauge or a second reading before replacing the DPF intake temperature
      2. 2Check that the DPF intake temperature circuit codes are not active, since a wiring fault can fake a high reading
      3. 3Look for the physical cause upstream, such as restriction, leakage, poor cooling or heavy load
      4. 4Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF intake temperature - above normal - most severe

    • Cummins 3318DPF intake temperature: Erratic reading

      The ECM judges the DPF intake temperature to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact on the DPF intake temperature
      • Part ageing or failing and giving unstable output
      • Electrical noise from a poorly routed wire or a bad ground

      Checks

      1. 1Watch the DPF intake temperature live in INSITE and wiggle the harness and connector to catch dropouts
      2. 2Compare the DPF intake temperature with a related reading to decide which one is wrong
      3. 3Check the connector for moisture and corrosion and the ground connection for tightness
      4. 4Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF intake temperature - data erratic or incorrect

  • DPF outlet temperature5 codes

    • Cummins 3255DPF outlet temperature: Above normal· moderately severe

      Same failure as 3311 on the DPF outlet temperature: the same fault condition as 3311, reported for this part.· Real condition
      Check soon

      Causes

      • Same causes as 3311, applied to the DPF outlet temperature
      • Wiring or connector problem local to the DPF outlet temperature

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3311, starting at the DPF outlet temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF outlet temperature - above normal - moderately severe

    • Cummins 3256DPF outlet temperature: Above normal· least severe

      Same failure as 3311 on the DPF outlet temperature: the same fault condition as 3311, reported for this part.· Real condition
      Info

      Causes

      • Same causes as 3311, applied to the DPF outlet temperature
      • Wiring or connector problem local to the DPF outlet temperature

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3311, starting at the DPF outlet temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF outlet temperature - above normal - least severe

    • Cummins 3312DPF outlet temperature: Above normal· most severe

      Same failure as 3311 on the DPF outlet temperature: the same fault condition as 3311, reported for this part.· Real condition
      Stop now

      Causes

      • Same causes as 3311, applied to the DPF outlet temperature
      • Wiring or connector problem local to the DPF outlet temperature

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3311, starting at the DPF outlet temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DPF outlet temperature - above normal - most severe

    • Cummins 3322DPF outlet temperature: Erratic reading

      Same failure as 3318 on the DPF outlet temperature: the same fault condition as 3318, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 3318, applied to the DPF outlet temperature
      • Wiring or connector problem local to the DPF outlet temperature

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3318, starting at the DPF outlet temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet temperature - data erratic or incorrect

    • Cummins 7894DPF outlet temperature: Abnormal rate of change

      The DPF outlet temperature changed faster than it physically could, so the ECM treats the reading as a sensor or wiring problem and not as a real change.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the harness or connector of the DPF outlet temperature
      • Failing part giving unstable output
      • Poor ground or noisy supply feeding the circuit

      Checks

      1. 1Log the DPF outlet temperature while moving the harness and connector, and look for steps instead of smooth changes
      2. 2Inspect the DPF outlet temperature connector for water, corrosion and loose pins
      3. 3Check the supply and ground at the DPF outlet temperature while the engine runs
      4. 4Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • DOC intake temperature sensor circuit2 codes

    • Cummins 3313DOC intake temperature sensor circuit: Voltage low / shorted low

      Same failure as 3316 on the DOC intake temperature sensor circuit: the same fault condition as 3316, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 3316, applied to the DOC intake temperature sensor circuit
      • Wiring or connector problem local to the DOC intake temperature sensor circuit

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 3316, starting at the DOC intake temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DOC intake temperature sensor circuit - voltage low (shorted to a low source)

    • Cummins 3314DOC intake temperature sensor circuit: Voltage high / shorted high

      Same failure as 3317 on the DOC intake temperature sensor circuit: the same fault condition as 3317, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3317, applied to the DOC intake temperature sensor circuit
      • Wiring or connector problem local to the DOC intake temperature sensor circuit

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 3317, starting at the DOC intake temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DOC intake temperature sensor circuit - voltage high (shorted to a high source)

  • DPF intake temperature sensor circuit2 codes

    • Cummins 3316DPF intake temperature sensor circuit: Voltage low / shorted low

      The ECM reads the DPF intake temperature sensor circuit below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the DPF intake temperature sensor circuit rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the DPF intake temperature sensor circuit connector

      Checks

      1. 1Key on, unplug the DPF intake temperature sensor circuit and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the DPF intake temperature sensor circuit signal wire to ground with the ECM unplugged to find a short
      4. 4Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DPF intake temperature sensor circuit - voltage low (shorted to a low source)

    • Cummins 3317DPF intake temperature sensor circuit: Voltage high / shorted high

      The ECM reads the DPF intake temperature sensor circuit above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the DPF intake temperature sensor circuit
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the DPF intake temperature sensor circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the DPF intake temperature sensor circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the DPF intake temperature sensor circuit back to the ECM
      4. 4Compare it with the DOC outlet reading, which should be close when no heat is lost between them.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DPF intake temperature sensor circuit - voltage high (shorted to a high source)

  • DPF outlet temperature sensor circuit2 codes

    • Cummins 3319DPF outlet temperature sensor circuit: Voltage high / shorted high

      Same failure as 3317 on the DPF outlet temperature sensor circuit: the same fault condition as 3317, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3317, applied to the DPF outlet temperature sensor circuit
      • Wiring or connector problem local to the DPF outlet temperature sensor circuit

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3317, starting at the DPF outlet temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DPF outlet temperature sensor circuit - voltage high (shorted to a high source)

    • Cummins 3321DPF outlet temperature sensor circuit: Voltage low / shorted low

      Same failure as 3316 on the DPF outlet temperature sensor circuit: the same fault condition as 3316, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 3316, applied to the DPF outlet temperature sensor circuit
      • Wiring or connector problem local to the DPF outlet temperature sensor circuit

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 3316, starting at the DPF outlet temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DPF outlet temperature sensor circuit - voltage low (shorted to a low source)

  • DOC outlet gas temperature1 code

    • Cummins 3394DOC outlet gas temperature: Below normal· moderately severe

      The DOC outlet gas temperature is below its normal range (severity: moderately severe).· Real condition
      Check soon

      Causes

      • A real shortfall in the system the DOC outlet gas temperature measures
      • Sensor or circuit reading low from a wiring fault
      • A leak, low level or weak supply that lets the value fall

      Checks

      1. 1Confirm the real condition with a gauge or a second reading before replacing the DOC outlet gas temperature
      2. 2Check that the DOC outlet gas temperature circuit codes are not active, since a wiring fault can fake a low reading
      3. 3Look for the physical cause upstream, such as a leak, low fluid, weak pump or blocked supply
      4. 4Compare it with the DOC intake reading during a regeneration to see whether the catalyst adds heat.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DOC outlet gas temperature - below normal - moderately severe

  • DOC intake temperature sensor2 codes

    • Cummins 6779DOC intake temperature sensor: Reading drifted high

      Same failure as 6784 on the DOC intake temperature sensor: the same fault condition as 6784, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 6784, applied to the DOC intake temperature sensor
      • Wiring or connector problem local to the DOC intake temperature sensor

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 6784, starting at the DOC intake temperature sensor and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DOC intake temperature sensor - data drifted high

    • Cummins 6781DOC intake temperature sensor: Reading drifted low

      Same failure as 6785 on the DOC intake temperature sensor: the same fault condition as 6785, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 6785, applied to the DOC intake temperature sensor
      • Wiring or connector problem local to the DOC intake temperature sensor

      Checks

      1. 1Compare it with the DOC outlet reading on a warm engine: the outlet should be warmer only when the catalyst is working.
      2. 2Work through the checks listed for 6785, starting at the DOC intake temperature sensor and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DOC intake temperature sensor - data drifted low

  • DOC outlet gas temperature sensor2 codes

    • Cummins 6782DOC outlet gas temperature sensor: Reading drifted high

      Same failure as 6784 on the DOC outlet gas temperature sensor: the same fault condition as 6784, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 6784, applied to the DOC outlet gas temperature sensor
      • Wiring or connector problem local to the DOC outlet gas temperature sensor

      Checks

      1. 1Compare it with the DOC intake reading during a regeneration to see whether the catalyst adds heat.
      2. 2Work through the checks listed for 6784, starting at the DOC outlet gas temperature sensor and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DOC outlet gas temperature sensor - data drifted high

    • Cummins 6783DOC outlet gas temperature sensor: Reading drifted low

      Same failure as 6785 on the DOC outlet gas temperature sensor: the same fault condition as 6785, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 6785, applied to the DOC outlet gas temperature sensor
      • Wiring or connector problem local to the DOC outlet gas temperature sensor

      Checks

      1. 1Compare it with the DOC intake reading during a regeneration to see whether the catalyst adds heat.
      2. 2Work through the checks listed for 6785, starting at the DOC outlet gas temperature sensor and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DOC outlet gas temperature sensor - data drifted low

  • DPF outlet temperature sensor3 codes

    • Cummins 6784DPF outlet temperature sensor: Reading drifted high

      The DPF outlet temperature sensor reads higher than the ECM calculates it should, and it has crept upward over time.· Erratic or implausible
      Check soon

      Causes

      • Sensing element ageing and reading high
      • Sensor contaminated by soot, oil or deposits
      • Slow rise in resistance in a connector or wire

      Checks

      1. 1Compare the DPF outlet temperature sensor with a known good sensor or a reference gauge at the same operating point
      2. 2Clean or replace the DPF outlet temperature sensor if it is contaminated, and check its sensing port for blockage
      3. 3Measure the voltage drop in the wiring to the DPF outlet temperature sensor for extra resistance
      4. 4Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet temperature sensor - data drifted high

    • Cummins 6785DPF outlet temperature sensor: Reading drifted low

      The DPF outlet temperature sensor reads lower than the ECM calculates it should, and it has crept downward over time.· Erratic or implausible
      Check soon

      Causes

      • Sensing element ageing and reading low
      • Sensor port blocked or leaking so it does not see the true value
      • Slow rise in resistance in a connector or wire

      Checks

      1. 1Compare the DPF outlet temperature sensor with a known good sensor or a reference gauge at the same operating point
      2. 2Inspect the DPF outlet temperature sensor sensing port and seals for blockage or leakage
      3. 3Measure the voltage drop in the wiring to the DPF outlet temperature sensor for extra resistance
      4. 4Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet temperature sensor - data drifted low

    • Cummins 6879DPF outlet temperature sensor: Reading drifted high

      Same failure as 6784 on the DPF outlet temperature sensor: the same fault condition as 6784, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 6784, applied to the DPF outlet temperature sensor
      • Wiring or connector problem local to the DPF outlet temperature sensor

      Checks

      1. 1Compare it with the DPF intake reading during a regeneration to see how much heat the filter holds.
      2. 2Work through the checks listed for 6784, starting at the DPF outlet temperature sensor and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DPF outlet temperature sensor - data drifted high

Shared checks

Checks, in order

  1. 1Read the DOC and DPF temperatures live with the engine cold: all four should match ambient and each other
  2. 2Unplug the suspect sensor and measure its resistance at ambient, then compare it with a good sensor of the same type
  3. 3Inspect the harness along the DOC and filter housing for burnt insulation and the connector for melted pins
  4. 4Compare the DOC outlet and DPF inlet readings on a warm engine: a large unexplained difference points to a sensor or a leak between them
  5. 5Check the regeneration and fuel doser codes so a real over-temperature is not missed

Causes

  • Harness or connector burnt where it passes near the DOC or filter housing
  • Failed thermistor reading out of range or drifting
  • Real over-temperature from a failed regeneration, fuel in the exhaust or a blocked filter
  • Fuel doser or DOC fault that stops the catalyst heating the exhaust as expected

Most common here: erratic or implausible (11 of 25)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A regeneration inhibit or derate and a lamp; the engine runs normally otherwise.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.