Thermo King · Refrigeration system (SR-2/SR-3/SR-4)
Thermo King Fault Code 82
High compressor temperature shutdown
What does Thermo King code 82 mean?
The compressor discharge temperature reached the shutdown limit and the controller stopped the unit to prevent damage to the compressor. Urgency: stop now - shut down and fix before working on. Check first: check for refrigerant leaks and recover or recharge as needed.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Check for refrigerant leaks and recover or recharge as needed
Then 3 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 4 done
Causes
- Low charge or loss of refrigerant cooling the compressor
- Condenser airflow blocked
- Compressor internal failure
- Liquid injection or economizer valve not working
How it failed
You'll notice: Alarm 82 and the unit shuts down; it may restart after cooling and shut down again if the cause is still there.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Evaporator, air and compressor temperature sensors
- 47Remote sensor shutdownOtherStop now
- 49Spare sensor 1 checkOtherInformation
- 80Check compressor temperature sensorReal conditionCheck soon
- 81High compressor temperatureOtherCheck soon
- 82High compressor temperature shutdownOtherStop now
- 92Sensor grades not setOtherInformation
- 97Failed remote return air sensor (CR)OtherCheck soon
- 150Sensor out of range lowShorted lowCheck soon
- 151Sensor out of range highOpen circuitCheck soon
Show the other 12 codesHide the other codes
- P1EReturn air temperature sensor faultOtherCheck soon
- 02Check evaporator coil sensorOtherCheck soon
- P2ERemote return air temperature sensor faultOtherCheck soon
- 03Check return air sensorOtherStop now
- 04Check discharge air sensorOtherCheck soon
- 05Check ambient temperature sensorOtherCheck soon
- 08Unit running on coil sensorOtherCheck soon
- 11Controlling on alternate sensorOtherCheck soon
- 12Sensor or digital input shutdownOtherStop now
- 13Sensor checkOtherCheck soon
- 203Check display return air sensorOtherCheck soon
- 204Check display discharge air sensorOtherCheck soon
Other Thermo King codes: Refrigeration system (SR-2/SR-3/SR-4)
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 82 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.