What does Thermo King code 10 mean?
Compressor discharge pressure or temperature went above the limit the controller allows. Continued running risks damaging the compressor and blowing the high pressure cutout. Urgency: stop now - shut down and fix before working on. Check first: look at the condenser coil face and clean it if it is plugged.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Look at the condenser coil face and clean it if it is plugged
Then 4 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 5 done
Causes
- Condenser coil blocked with dirt, leaves or bugs
- Condenser fan or fan belt not turning properly
- Overcharge or air or non-condensables in the system
- Receiver or liquid line restricted
How it failed
You'll notice: Alarm 10 and the unit may shut down or run at reduced capacity.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Refrigeration pressures, scroll compressor limits, modulation and drive
1 other code on this part is also shorted high (HP). When they show together, start at the wiring and connector they share.
- HPHigh discharge pressureShorted highStop now
- LPLow suction pressureOtherStop now
- PSEHigh pressure sensor faultReal conditionStop now
- 10High discharge pressure or temperatureShorted highStop now
- 34Check modulation circuitOtherCheck soon
- 48Check belts or clutchOtherCheck soon
- 86Check discharge pressure sensorOtherCheck soon
- 87Check suction pressure sensorOtherCheck soon
- 93Low compressor suction pressureOtherCheck soon
Show the other 14 codesHide the other codes
- 94Check loader 1 circuitOtherCheck soon
- 95Check loader 2 circuitOtherCheck soon
- 99High compressor pressure ratioReal conditionCheck soon
- 115Check high pressure cutout switchReal conditionStop now
- 116High pressure cut-in switch checkReal conditionInformation
- 154Low suction pressure switch failureOtherCheck soon
- 180TriPac compressor alarmOtherCheck soon
- 507Digital scroll output circuit check (scroll only)OtherInformation
- 512High compressor suction pressure (scroll only)OtherCheck soon
- 513Low compressor suction ratio (scroll only)Lost messageCheck soon
- 514Low compressor discharge pressure (scroll only)OtherCheck soon
- 515Minimum ETV discharge superheat temperature (scroll)OtherCheck soon
- 530Low pressure differential (scroll only)Real conditionCheck soon
- 531Economizer pressure sensor check (scroll only)OtherCheck soon
Other Thermo King codes: Refrigeration system (SR-2/SR-3/SR-4)
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 10 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.