Thermo King · Temperature sensors (SR-2/SR-3/SR-4)
Thermo King Fault Code 03
Check return air sensor
What does Thermo King code 03 mean?
The return air sensor reading is out of range, which means the controller does not know the real box air temperature. Return air is the main control sensor on most units, so this one matters. Urgency: stop now - shut down and fix before working on. Check first: look at the sensor in the return air stream and its lead for physical damage.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Look at the sensor in the return air stream and its lead for physical damage
Then 4 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 5 done
Causes
- Return air sensor in the evaporator inlet damaged by cargo or forklift
- Harness break near the evaporator bulkhead penetration
- Connector at the controller or sensor pigtail corroded
- Sensor failed open or shorted internally
How it failed
You'll notice: Alarm 03 on the display; the unit may swap to the display or alternate sensor, or hold the last operating state, and box temperature can drift without the unit reacting.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Evaporator, air and compressor temperature sensors
- P1EReturn air temperature sensor faultOtherCheck soon
- 02Check evaporator coil sensorOtherCheck soon
- P2ERemote return air temperature sensor faultOtherCheck soon
- 03Check return air sensorOtherStop now
- 04Check discharge air sensorOtherCheck soon
- 05Check ambient temperature sensorOtherCheck soon
- 08Unit running on coil sensorOtherCheck soon
- 11Controlling on alternate sensorOtherCheck soon
- 12Sensor or digital input shutdownOtherStop now
Show the other 12 codesHide the other codes
- 13Sensor checkOtherCheck soon
- 47Remote sensor shutdownOtherStop now
- 49Spare sensor 1 checkOtherInformation
- 80Check compressor temperature sensorReal conditionCheck soon
- 81High compressor temperatureOtherCheck soon
- 82High compressor temperature shutdownOtherStop now
- 92Sensor grades not setOtherInformation
- 97Failed remote return air sensor (CR)OtherCheck soon
- 150Sensor out of range lowShorted lowCheck soon
- 151Sensor out of range highOpen circuitCheck soon
- 203Check display return air sensorOtherCheck soon
- 204Check display discharge air sensorOtherCheck soon
Other Thermo King codes: Temperature sensors (SR-2/SR-3/SR-4)
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 03 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.