Thermo King · Temperature sensors (SR-2/SR-3/SR-4)
Thermo King Fault Code 02
Check evaporator coil sensor
What does Thermo King code 02 mean?
The controller reads the evaporator coil temperature sensor outside its valid range, so it cannot see frost building on the coil. Defrost decisions fall back to timers or other sensors. Urgency: check soon - the machine may derate or limit a function. Check first: find the coil sensor on the evaporator and trace its leads to the unit harness for damage.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Find the coil sensor on the evaporator and trace its leads to the unit harness for damage
Then 5 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 6 done
Causes
- Coil sensor wire chafed or cut where it leaves the evaporator
- Sensor connector at the controller corroded or pushed back
- Sensor probe itself open or shorted internally
- Water in the splice protected by the heat-shrink at the coil
How it failed
You'll notice: Alarm 02 shows on the display and defrost may start on time alone, so the coil can ice up or defrost too often.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Evaporator, air and compressor temperature sensors
- P1EReturn air temperature sensor faultOtherCheck soon
- 02Check evaporator coil sensorOtherCheck soon
- P2ERemote return air temperature sensor faultOtherCheck soon
- 03Check return air sensorOtherStop now
- 04Check discharge air sensorOtherCheck soon
- 05Check ambient temperature sensorOtherCheck soon
- 08Unit running on coil sensorOtherCheck soon
- 11Controlling on alternate sensorOtherCheck soon
- 12Sensor or digital input shutdownOtherStop now
Show the other 12 codesHide the other codes
- 13Sensor checkOtherCheck soon
- 47Remote sensor shutdownOtherStop now
- 49Spare sensor 1 checkOtherInformation
- 80Check compressor temperature sensorReal conditionCheck soon
- 81High compressor temperatureOtherCheck soon
- 82High compressor temperature shutdownOtherStop now
- 92Sensor grades not setOtherInformation
- 97Failed remote return air sensor (CR)OtherCheck soon
- 150Sensor out of range lowShorted lowCheck soon
- 151Sensor out of range highOpen circuitCheck soon
- 203Check display return air sensorOtherCheck soon
- 204Check display discharge air sensorOtherCheck soon
Other Thermo King codes: Temperature sensors (SR-2/SR-3/SR-4)
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 02 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?