EF Logo

JLG · Electrical

JLG Fault Code 4‑4

Battery supply problem

What does JLG code 4-4 mean?

Battery voltage is outside the controller's limits. Under 11 V for over 5 s gives a warning only (BATTERY LOW). Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage at rest and while cranking.

FaultCheck4-4JLG · Electrical

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Measure battery voltage at rest and while cranking

Then 4 more checks
Code shows hereFAULT4-4

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • Weak or discharged starting battery
  • Loose or corroded battery terminals or main ground
  • Alternator undercharging or overcharging (regulator failed)
  • Voltage drop in the supply wire to the ground module

How it failed

You'll notice: The platform display or lamp shows a battery voltage problem with a 4-4 flash.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs

Source

JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)

This source lists 4-4 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG boom lifts with the JLG Control System (600S, 600SJ, 660SJ, 600A/AJ, 450A, 510A, 400S, 1200/1350SJP families).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request