JLG Load sensing, chassis tilt and transport sensors fault codes

The load sensing cells measure the weight in the platform, the load sensing module reads them and supplies the cells, and the chassis tilt sensor reports the angle of the machine. The boom transport switch input is also read here.

More about these parts

The controller uses these to enforce the rated load and tilt limits.

FaultCheck813JLG · Load sensing, chassis tilt and transport sensors
Code shows hereFAULT813

Where this code shows

Turn the key on and watch the fault lamp or platform display.

What do these codes mean?

JLG codes 0014 to 23104 are all about the load sensing, chassis tilt and transport sensors. The most common failure type is part or controller (5 of 19); none needs an immediate stop. Start with this check: read the load or tilt value in the analyzer with the platform empty and the machine level.

How urgent are they?

None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.

  • Check soon19

What should I check first?

Read the load or tilt value in the analyzer with the platform empty and the machine level

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JLG 0014Chassis tilt sensor out of range

    The chassis tilt sensor reports a value outside its valid range, so the tilt cutout cannot be trusted.· Other
    Check soon

    Causes

    • Tilt sensor damaged or loose on its mount
    • Sensor connector corroded or pins pushed back
    • Sensor reference supply low from a short on a shared sensor feed
    • Machine really standing far off level

    Checks

    1. 1Park the machine on level ground and read the tilt value in the analyzer; it should be near level
    2. 2Check the sensor is firmly mounted and that its connector is dry, clean and fully latched
    3. 3Measure the sensor reference supply at its connector and compare with the other sensors on the same module
    4. 4Wiggle the harness near the sensor while watching the reading for jumps
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 443LSS battery voltage too high

    The supply seen by the load sensing module is above its limit, which can come from the charging system or a wiring fault.· Shorted high
    Check soon

    Causes

    • Charging system overvoltage
    • Poor ground at the module

    Checks

    1. 1Measure battery voltage at the module
    2. 2Check the charging system and the module ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JLG 444LSS battery voltage too low

    The supply seen by the load sensing module is below its limit, which can come from a weak battery or a poor connection.· Shorted low
    Check soon

    Causes

    • Weak battery or voltage drop
    • Loose connector or ground

    Checks

    1. 1Measure battery voltage at the module
    2. 2Check terminals, grounds and the module connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JLG 813Chassis tilt sensor not calibrated

    The chassis tilt sensor has not been calibrated, so the controller cannot use its tilt readings reliably.· Other
    Check soon

    Causes

    • Tilt sensor recently replaced and not calibrated
    • Calibration data lost after a module or software change
    • Calibration never done at commissioning
    • Sensor shifted on its mount after an impact

    Checks

    1. 1Park the machine on firm level ground and confirm the chassis is level with a spirit level
    2. 2Calibrate the chassis tilt sensor with the analyzer following the procedure in the service manual
    3. 3Check the sensor is firmly mounted and its connector is clean and latched
    4. 4Read the tilt value after calibration and confirm it is close to level
    5. 5Replace the sensor if calibration will not hold
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 814Chassis tilt sensor out of range

    The chassis tilt sensor reports a value outside its valid range, so the tilt cutout cannot be trusted.· Other
    Check soon

    Causes

    • Tilt sensor damaged, loose or on a bent bracket
    • Sensor wire or connector faulty

    Checks

    1. 1Read the tilt value on level ground in the analyzer
    2. 2Check the sensor mounting and plug
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 815Chassis tilt sensor disagreement

    The two tilt readings compared by the controller disagree with each other, so it cannot tell whether the machine is level and may limit drive and boom.· Other
    Check soon

    Causes

    • One tilt channel failing or drifting
    • Sensor loose or damaged

    Checks

    1. 1Compare both tilt values in the analyzer on level ground
    2. 2Recalibrate or replace the sensor if they differ
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 821LSS cell 1 error

    Load cell 1 of the load sensing system reports an error, so the LSS cannot measure platform load reliably.· Real condition
    Check soon

    Causes

    • Load cell or its wire damaged
    • Overload event that pushed the cell out of range
    • Connector corrosion at the load cell
    • LSS module input fault

    Checks

    1. 1Read the LSS data in the analyzer and note the reading from cell 1 against the others
    2. 2Inspect the load cell cable and connector for damage and corrosion
    3. 3Check the cell mounting for damage or loose fasteners
    4. 4Recalibrate the load sensing system following the service manual procedure
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JLG 822LSS cell 2 error

    The load sensing system reports an error on cell #2, so the platform weight cannot be trusted and load protection may be disabled.· Other
    Check soon

    Causes

    • Load cell or its wire damaged
    • Cell connector corroded or wet

    Checks

    1. 1Read cell #2 in the analyzer and compare it with the other cells
    2. 2Check its connector and wire, then recalibrate
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 823LSS cell 3 error

    The load sensing system reports an error on cell #3, so the platform weight cannot be trusted and load protection may be disabled.· Other
    Check soon

    Causes

    • Load cell or its wire damaged
    • Cell connector corroded or wet

    Checks

    1. 1Read cell #3 in the analyzer and compare it with the other cells
    2. 2Check its connector and wire, then recalibrate
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 824LSS cell 4 error

    The load sensing system reports an error on cell #4, so the platform weight cannot be trusted and load protection may be disabled.· Other
    Check soon

    Causes

    • Load cell or its wire damaged
    • Cell connector corroded or wet

    Checks

    1. 1Read cell #4 in the analyzer and compare it with the other cells
    2. 2Check its connector and wire, then recalibrate
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 825LSS has not been calibrated

    The load sensing system has not been calibrated, so it cannot weigh the platform accurately and the controller may limit functions until it is.· Other
    Check soon

    Causes

    • System not calibrated after a repair or module change
    • Calibration data lost

    Checks

    1. 1Calibrate the load sensing system following the manual
    2. 2Check an empty platform reads near zero afterwards
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 991LSS watchdog reset

    The load sensing module restarted itself after its watchdog fired, which points to a supply dip or an internal problem in that module.· Other
    Check soon

    Causes

    • Supply to the LSS module dipping
    • Internal module fault

    Checks

    1. 1Measure the supply at the LSS module with the key on
    2. 2Replace the module if resets continue
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 992LSS EEPROM error

    The load sensing module found an error in its stored memory, so its calibration data cannot be trusted.· Part or controller
    Check soon

    Causes

    • Memory corrupted by a supply glitch
    • Module memory failing

    Checks

    1. 1Reload calibration and settings
    2. 2Replace the module if the error returns
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • JLG 993LSS internal error - Pin excitation

    The load sensing module found an error in the excitation supply it gives its load cells, so the readings cannot be trusted.· Part or controller
    Check soon

    Causes

    • Excitation circuit damaged or shorted by a cell wire
    • Module fault

    Checks

    1. 1Unplug the cells one at a time to find a short
    2. 2Replace the module if the error stays with no cells connected
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • JLG 994LSS internal error - DRDY missing from A/D

    The analogue-to-digital converter in the load sensing module is not signalling that data is ready, so the module cannot read its cells.· Part or controller
    Check soon

    Causes

    • Converter or module failing
    • Supply to the module unstable

    Checks

    1. 1Check the supply at the module
    2. 2Replace the module if the error is permanent
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • JLG 8211LSS reading under weight

    The load sensing reading is below the expected empty weight, which usually means a cell, wire or calibration problem rather than a real load.· Part or controller
    Check soon

    Causes

    • Cell reading drifted low
    • Cell wire open or calibration wrong

    Checks

    1. 1Read each cell with an empty platform and look for one that is low
    2. 2Recalibrate and check the wiring
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • JLG 9915Chassis tilt sensor not gain calibrated

    The tilt sensor has not been gain calibrated, so its scale is not set and the controller cannot trust the reading.· Other
    Check soon

    Causes

    • Sensor or module replaced without calibration
    • Calibration data lost

    Checks

    1. 1Run the tilt sensor gain calibration in the analyzer
    2. 2Check the reading afterwards on level ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 9977LSS corrupt EEPROM

    The load sensing module found its stored memory corrupt, so calibration and settings are lost until reloaded.· Part or controller
    Check soon

    Causes

    • Memory corrupted by a supply glitch
    • Module memory failing

    Checks

    1. 1Reload the settings and calibrate
    2. 2Replace the module if the memory will not hold
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • JLG 23104Boom transport switch disagreement

    The two boom transport (stowed) switches disagree about whether the boom is stowed.· Real condition
    Check soon

    Causes

    • One transport switch failed or misaligned
    • Switch wire open or shorted
    • Target gap wrong after boom adjustment or impact
    • Connector corroded at one of the switches
    • Switch mounting bracket bent

    Checks

    1. 1Stow the boom and compare both transport switch states in the analyzer diagnostics
    2. 2Check each switch gap and target against the manual and look for a bent bracket
    3. 3Test each switch with a meter or by watching its input as a metal target is moved in and out
    4. 4Inspect the wiring and connectors for chafing and water
    5. 5Replace the switch that does not match the true boom position
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Read the load or tilt value in the analyzer with the platform empty and the machine level
  2. 2Check the supply to the load sensing module and the sensor reference voltage
  3. 3Inspect cables and connectors from the cells or tilt sensor for damage and green pins
  4. 4Recalibrate the sensor or system as the manual requires after any repair
  5. 5Replace the sensor that stays out of range and recheck

Causes

  • A load cell or its cable damaged or out of calibration
  • Supply or reference voltage to the load sensing module out of range
  • Tilt sensor loose, damaged or mounted off level
  • Corroded connector at the module

Most common here: part or controller (5 of 19)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: The platform load or tilt cutout acts up: functions are prevented, an overload shows with an empty basket, or a tilt alarm sounds on level ground.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.