JLG · Sensors
JLG Fault Code 813
Chassis tilt sensor not calibrated
What does JLG code 813 mean?
The chassis tilt sensor has not been calibrated, so the controller cannot use its tilt readings reliably. Tilt based limits may behave incorrectly until it is calibrated. Urgency: check soon - the machine may derate or limit a function. Check first: park the machine on firm level ground and confirm the chassis is level with a spirit level.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Park the machine on firm level ground and confirm the chassis is level with a spirit level
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Tilt sensor recently replaced and not calibrated
- Calibration data lost after a module or software change
- Calibration never done at commissioning
- Sensor shifted on its mount after an impact
How it failed
You'll notice: The tilt cutout may behave wrongly because the chassis tilt sensor has no calibration stored.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Load sensing, chassis tilt and transport sensors
- 0014Chassis tilt sensor out of rangeOtherCheck soon
- 443LSS battery voltage too highShorted highCheck soon
- 444LSS battery voltage too lowShorted lowCheck soon
- 813Chassis tilt sensor not calibratedOtherCheck soon
- 814Chassis tilt sensor out of rangeOtherCheck soon
- 815Chassis tilt sensor disagreementOtherCheck soon
- 821LSS cell 1 errorReal conditionCheck soon
- 822LSS cell 2 errorOtherCheck soon
- 823LSS cell 3 errorOtherCheck soon
Show the other 10 codesHide the other codes
- 824LSS cell 4 errorOtherCheck soon
- 825LSS has not been calibratedOtherCheck soon
- 991LSS watchdog resetOtherCheck soon
- 992LSS EEPROM errorPart or controllerCheck soon
- 993LSS internal error - pin excitationPart or controllerCheck soon
- 994LSS internal error - DRDY missing from A/DPart or controllerCheck soon
- 8211LSS reading under weightPart or controllerCheck soon
- 9915Chassis tilt sensor not gain calibratedOtherCheck soon
- 9977LSS corrupt EEPROMPart or controllerCheck soon
- 23104Boom transport switch disagreementReal conditionCheck soon
Other JLG codes: Sensors
Related on Equipments Finder
Source
JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
This source lists 813 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.