JLG · Electrical
JLG Fault Code 3‑3
Driver (output) short or open circuit
What does JLG code 3-3 mean?
One of the ground module outputs (valve coil, brake, horn, engine start and so on) failed its feedback check. Open circuit: feedback reads high with the output off. Urgency: check soon - the machine may derate or limit a function. Check first: read the Help message to see which output and which fault type (open, short to ground, short to battery).
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Read the Help message to see which output and which fault type (open, short to ground, short to battery)
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Open or burnt coil on the output named in the Help message
- Wire to the named coil shorted to the frame where it rubs
- Wire touching a battery-fed circuit, putting supply voltage on the output
- Water or corrosion in the coil plug or valve connector
1 more causeFewer causes
- Ground module output driver damaged
How it failed
You'll notice: This flash code covers many ground module outputs, so the symptom depends on which coil is named in the Help text.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Other JLG codes: Electrical
Related on Equipments Finder
Source
JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)
This source lists 3-3 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG boom lifts with the JLG Control System (600S, 600SJ, 660SJ, 600A/AJ, 450A, 510A, 400S, 1200/1350SJP families).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?