EF Logo

JLG · Outputs (valves and coils)

JLG Drive brake, traction lock, oscillating axle and dump valves fault codes

These are the valves that hold and release the chassis: the drive brake release, the traction lock valve, the oscillating axle lock, and the main dump and steer dump valves that dump pump flow. The module energises them and watches the output.

FaultStop331JLG · Brake
Code shows hereFAULT331

Where this code shows

Turn the key on and watch the fault lamp or platform display.

What do these codes mean?

JLG codes 3-5 to 33424 are all about the drive brake, traction lock, oscillating axle and dump valves. The most common failure type is shorted high (5 of 16); 9 need an immediate stop. Start with this check: read the code to see which valve is named and note exactly what the analyzer shows.

How urgent are they?

9 of 16 codes here mean stop now; the other 7 can wait until the shift ends, but find the cause before the next one.

  • Stop now9
  • Check soon7

What should I check first?

Read the code to see which valve is named and note exactly what the analyzer shows

Shared checks

16 of 16

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Brake3 codes

    • JLG 331Brake: Short to battery

      The controller reads battery voltage on the brake output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Stop now

      Causes

      • Supply leaking onto the output wire through damaged insulation
      • Brake output touched by a supply wire in the drive harness, so the brake is told to release when it should be held
      • Supply wire pinched against the output wire along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing
      • Crushed pin touching a live neighbour; the brake valve plug sits low on the drive manifold and collects wash water and road spray

      Checks

      1. 1Pull the plug on the drive manifold at the chassis, key on, and check the output wire for voltage; if it stays with the load off, suspect the module
      2. 2Trace the wire alongside any supply wire and look for a touch point along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing
      3. 3With the analyzer open, move the drive joystick and listen for the brake valve to click, then see whether the wheels release and compare the output voltage with the commanded state
      4. 4With the machine parked and chocked, key on and plug off, check the brake wire for voltage before anyone tries to drive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • JLG 332Brake: Open circuit

      The controller drives the brake output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Stop now

      Causes

      • Broken internal lead in the solenoid coil
      • Brake release coil open, so the brakes never get the pressure to lift and the machine stays held
      • Conductor snapped in the harness along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing
      • Terminal worn loose in its housing (the brake valve plug sits low on the drive manifold and collects wash water and road spray)
      • Return wire off its ring terminal

      Checks

      1. 1Ohm the solenoid coil on the drive manifold at the chassis with the plug off and compare with a matching good coil
      2. 2Check continuity from the module output pin to the plug, wiggling the wire as you test, starting along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing
      3. 3Command the output from the analyzer and move the drive joystick and listen for the brake valve to click, then see whether the wheels release
      4. 4Compare the brake coil reading with the drive coils on the same manifold; the brake coil should read like its neighbours, not open
      5. 5Release the brakes by the method in the machine manual and see whether the machine rolls freely; if it does, the brake hydraulics are fine and the fault is electrical
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 3361Brake: Short to ground

      The controller sees the brake output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Stop now

      Causes

      • Coil winding rubbing its own case until it earths
      • Brake release coil cooked by years of heat and washdown until it leaks to its case, so the brakes cannot be released on command
      • Wire chafed through to the frame along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing
      • Dirt and water bridging a pin to ground; the brake valve plug sits low on the drive manifold and collects wash water and road spray

      Checks

      1. 1Pull the plug on the drive manifold at the chassis and recycle EMS to see whether the code stays
      2. 2Meter the signal wire to the frame, flexing it along the chassis frame rails near the drive motors, where heat and road debris wear the sheathing for a reading that comes and goes
      3. 3Move the drive joystick and listen for the brake valve to click, then see whether the wheels release; the analyzer output should go to supply, not stay at zero
      4. 4Roll the wheels by hand with the machine stopped and the plug off; if they turn freely the brakes were not stuck mechanically and the coil is the suspect
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Main Dump Valve3 codes

    • JLG 3358Main Dump Valve: Short to ground

      The controller sees the main dump valve output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Stop now

      Causes

      • Burnt turns grounding the main dump valve output
      • Main dump coil shorted by oil and water in the turntable manifold plug, killing boom flow
      • Signal wire rubbed bare on metal on the turntable manifold where oil mist soaks into the harness
      • Wet or corroded plug, since the dump valve plug is on the turntable manifold, wet with oil mist and washdown water

      Checks

      1. 1Disconnect the load on the hydraulic manifold at the turntable; the code staying means a harness or module fault
      2. 2Look for rub marks on the harness on the turntable manifold where oil mist soaks into the harness and test any suspect length to earth
      3. 3With the analyzer open, select any boom function and check whether the main dump coil clicks and pressure builds and watch the output state
      4. 4Wipe and dry the dump valve plug, then recheck: a coil that was only wet will clear
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 3359Main Dump Valve: Open circuit

      The controller drives the main dump valve output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Stop now

      Causes

      • Winding burnt through at one end so the coil reads open
      • Main dump coil open, so the pump flow is not directed to the boom functions and they all go weak at once
      • Lead stretched or kinked until it broke on the turntable manifold where oil mist soaks into the harness
      • Contact fretting in the plug, which is likely because the dump valve plug is on the turntable manifold, wet with oil mist and washdown water

      Checks

      1. 1Meter the solenoid coil on the hydraulic manifold at the turntable for an open reading
      2. 2Test between the module pin and the plug section by section, beginning on the turntable manifold where oil mist soaks into the harness
      3. 3Select any boom function and check whether the main dump coil clicks and pressure builds; the analyzer should show the module sending the command
      4. 4Select two different boom functions: if both are dead or slow the main dump circuit is the common cause
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 3360Main Dump Valve: Short to battery

      The controller reads battery voltage on the main dump valve output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Stop now

      Causes

      • Supply leaking onto the output wire through damaged insulation
      • Main dump wire touching a feed in the turntable loom, so the valve is held on when it should be off
      • Chafed insulation on the turntable manifold where oil mist soaks into the harness letting a feed touch the output wire
      • Corrosion between pins in the plug (the dump valve plug is on the turntable manifold, wet with oil mist and washdown water)

      Checks

      1. 1With the load off on the hydraulic manifold at the turntable and the key on, any reading on the output wire is the short
      2. 2Feel along the harness on the turntable manifold where oil mist soaks into the harness for scuffed, hard or discoloured insulation
      3. 3Retest after the repair: select any boom function and check whether the main dump coil clicks and pressure builds
      4. 4Key on with the dump plug off and check the wire for voltage before looking at the other boom valves
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Steer Dump Valve3 codes

    • JLG 3365Steer Dump Valve: Short to ground

      The controller sees the steer dump valve output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Stop now

      Causes

      • Coil winding rubbing its own case until it earths
      • Steer dump coil cooked and shorted to its case at the chassis manifold
      • Wire chafed through to the frame along the chassis near the steer cylinders and axle
      • Dirt and water bridging a pin to ground; the steer valve plug is on the chassis manifold, low enough to take mud and spray

      Checks

      1. 1Unplug the steer dump valve on the drive manifold at the chassis; if the code clears the solenoid coil is the short, if not the wiring or module is
      2. 2Test the output wire to the chassis with the connector open; any path is the short, most likely along the chassis near the steer cylinders and axle
      3. 3Press the steer switch and listen for the steer dump valve to click; the analyzer output should go to supply, not stay at zero
      4. 4Meter the steer dump coil to its case with the plug off; a reading to the body is a failed coil
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 3366Steer Dump Valve: Open circuit

      The controller drives the steer dump valve output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Stop now

      Causes

      • Steer dump valve solenoid coil burnt out or open
      • Steer dump coil open, so the steer circuit gets no oil and the wheels will not follow the rocker
      • Wire broken inside its insulation along the chassis near the steer cylinders and axle
      • Pin backed out or loose in the connector, because the steer valve plug is on the chassis manifold, low enough to take mud and spray

      Checks

      1. 1Unplug the steer dump valve on the drive manifold at the chassis and measure across its two pins; an open reading means a dead solenoid coil
      2. 2Meter the wires end to end while someone moves the harness along the chassis near the steer cylinders and axle
      3. 3Command the output from the analyzer and press the steer switch and listen for the steer dump valve to click
      4. 4Check that the drive function still works: if it does, the pump is fine and the steer dump circuit is the open one
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 3367Steer Dump Valve: Short to battery

      The controller reads battery voltage on the steer dump valve output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Stop now

      Causes

      • Insulation worn between the signal and a supply feed
      • Steer dump wire touching a feed in the chassis loom, so the steer dump is held on and steering may act without being asked
      • Supply wire pinched against the output wire along the chassis near the steer cylinders and axle
      • Corrosion between pins in the plug (the steer valve plug is on the chassis manifold, low enough to take mud and spray)

      Checks

      1. 1With the load off on the drive manifold at the chassis and the key on, any reading on the output wire is the short
      2. 2Trace the wire alongside any supply wire and look for a touch point along the chassis near the steer cylinders and axle
      3. 3Watch the analyzer output as you press the steer switch and listen for the steer dump valve to click
      4. 4Key on, plug off, and check the wire for voltage; look at the loom beside the brake and drive wires
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Traction Lock Valve3 codes

    • JLG 33420Traction Lock Valve: Short to battery

      The controller reads battery voltage on the traction lock valve output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Two harness legs bundled so tightly that a worn spot joins them
      • Traction lock wire touching a feed in the chassis loom so the lock is held on
      • Supply wire pinched against the output wire along the chassis where the drive manifold harness is exposed to mud and spray
      • Water tracking between supply and signal pins (the traction lock plug is at the drive manifold, exposed to mud and spray)

      Checks

      1. 1Check for supply on the output wire at the open connector on the drive manifold
      2. 2Look for a wire crossing a live feed along the chassis where the drive manifold harness is exposed to mud and spray, and separate or replace it
      3. 3Watch the analyzer output as you drive and listen for the traction lock valve to click
      4. 4Watch whether the traction lock stays engaged with nothing selected
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • JLG 33421Traction Lock Valve: Open circuit

      The controller drives the traction lock valve output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Check soon

      Causes

      • Coil gone open from heat or age
      • Traction lock coil open, so the lock never engages or releases on command
      • Wire work-hardened and snapped inside its sheath along the chassis where the drive manifold harness is exposed to mud and spray
      • Terminal pushed back or plug not latched, since the traction lock plug is at the drive manifold, exposed to mud and spray

      Checks

      1. 1Check the coil on the drive manifold for an open winding, comparing with a good one if you have it
      2. 2Meter the wires end to end while someone moves the harness along the chassis where the drive manifold harness is exposed to mud and spray
      3. 3With the analyzer open, drive and listen for the traction lock valve to click; if the output switches but nothing happens, the solenoid coil is open
      4. 4Drive and see whether a wheel spins freely or the machine will not move
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 33422Traction Lock Valve: Short to ground

      The controller sees the traction lock valve output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Burnt turns grounding the traction lock valve output
      • Traction lock coil shorted by mud and spray at the drive manifold
      • Wire chafed through to the frame along the chassis where the drive manifold harness is exposed to mud and spray
      • Dirt and water bridging a pin to ground; the traction lock plug is at the drive manifold, exposed to mud and spray

      Checks

      1. 1Disconnect the load on the drive manifold; the code staying means a harness or module fault
      2. 2Meter between the signal pin and chassis with the plug apart; a reading shows the earth path, probably along the chassis where the drive manifold harness is exposed to mud and spray
      3. 3Drive and listen for the traction lock valve to click; the analyzer output should go to supply, not stay at zero
      4. 4Wash and dry the manifold plug and meter the coil to its case
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Oscillating Axle Valves2 codes

    • JLG 33423Oscillating Axle Valves: Short to battery

      The controller reads battery voltage on the oscillating axle valves output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Two harness legs bundled so tightly that a worn spot joins them
      • Axle valve wire touching a feed so the lockout stays on and the axle cannot float
      • Harness rubbed bare and touching a feed on the axle where wiring is exposed to wheel spray
      • Crushed pin touching a live neighbour; the axle valve plugs are low on the axle and take wheel spray

      Checks

      1. 1Pull the plug at the axle and its lockout cylinders, key on, and check the output wire for voltage; if it stays with the load off, suspect the module
      2. 2Trace the wire alongside any supply wire and look for a touch point on the axle where wiring is exposed to wheel spray
      3. 3Watch the analyzer output as you raise the boom and listen for the axle valves to click and lock
      4. 4Drive over uneven ground slowly: a locked axle that does not float shows the output is held on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • JLG 33424Oscillating Axle Valves: Short to ground

      The controller sees the oscillating axle valves output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Oscillating axle valves solenoid coil shorted to its case
      • Axle valve coil shorted by wheel spray, so the lockout cannot be controlled
      • Signal wire rubbed bare on metal on the axle where wiring is exposed to wheel spray
      • Wet or corroded plug, since the axle valve plugs are low on the axle and take wheel spray

      Checks

      1. 1Disconnect the load at the axle and its lockout cylinders; the code staying means a harness or module fault
      2. 2Test the output wire to the chassis with the connector open; any path is the short, most likely on the axle where wiring is exposed to wheel spray
      3. 3With the analyzer open, raise the boom and listen for the axle valves to click and lock and watch the output state
      4. 4Check the axle valve plugs for water and meter the coils to their case
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Other codes2 codes

    • JLG 3-5Brake pressure problem

      The controller has flagged a problem with brake pressure or the brake release circuit.· Other
      Check soon

      Causes

      • Brake release valve coil open or shorted
      • Brake release pressure low from a worn drive pump or a leaking brake circuit
      • Pressure switch or sensor for the brake circuit failed
      • Harness or connector at the brake valve damaged

      Checks

      1. 1Read the analyzer message and the brake output state in the diagnostics screen while commanding drive
      2. 2Connect a pressure gauge at the brake release test port and compare with the specification in the manual for this machine
      3. 3Check the brake valve coil connector and measure the supply while the output is commanded on
      4. 4Ohm the brake valve coil and compare with a matching coil; replace if open or shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • JLG 8669Oscillating axle switch disagreement

      The two oscillating axle switch signals disagree with each other, so the controller cannot tell the axle position.· Other
      Check soon

      Causes

      • One axle switch misadjusted or failed
      • Switch wire or connector faulty

      Checks

      1. 1Compare both switch inputs in the analyzer
      2. 2Adjust or replace the switch and check the wiring
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the code to see which valve is named and note exactly what the analyzer shows
  2. 2Command it from the analyzer and listen for the click
  3. 3Check the harness and plug at the valve and note exactly what the analyzer shows
  4. 4Ohm the coil against its partner and note exactly what the analyzer shows
  5. 5Retest the brake or axle function after the repair

Causes

  • Brake or lock coil failed
  • Harness damaged at the axle or chassis
  • Plug loose or corroded
  • Output driver in the module damaged

Most common here: shorted high (5 of 16)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The machine will not move or will not stop, the axle stays locked or the pump flow is dumped, and the code names the valve.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.