JLG · Electrical
JLG Fault Code 445
Battery voltage low (warning)
What does JLG code 445 mean?
Battery voltage is below about 11 V for over 5 seconds, not counting cranking. The controller keeps running but it is warning that the battery is weak. Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage at rest and with the engine running.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure battery voltage at rest and with the engine running
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Weak or old battery that will not hold charge
- Alternator undercharging because of a slipping belt or bad output
- Loose or corroded terminals dropping voltage under load
- Large load left on, such as lights or accessories
How it failed
You'll notice: A low battery warning shows but the machine keeps running, with the voltage under about 11 V for more than 5 seconds.
Shorted lowRead from how the source describes the code
The signal sits at or near zero volts - less than a working sensor can send.
- Meter test
- Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
- Good result
- Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs
6 other codes on this part are also shorted low (441, 3362, 3373, 3376 and more). When they show together, start at the wiring and connector they share.
- 3-2Contactor did not openOtherCheck soon
- 4-4Battery supply problemOtherCheck soon
- 441Battery voltage too low - system shutdownShorted lowStop now
- 442Battery voltage too high - system shutdownShorted highStop now
- 445Battery voltage low (warning)Shorted lowCheck soon
- 3311Ground Alarm - short to batteryShorted highCheck soon
- 3362Start Solenoid - short to groundShorted lowCheck soon
- 3363Start Solenoid - open circuitOpen circuitCheck soon
- 3364Start Solenoid - short to batteryShorted highCheck soon
Show the other 12 codesHide the other codes
- 3-1Contactor did not closeOtherCheck soon
- 3373Generator/welder - short to groundShorted lowCheck soon
- 3374Generator/welder - open circuitOpen circuitCheck soon
- 3375Generator/welder - short to batteryShorted highCheck soon
- 3376Head Tail Light - short to groundShorted lowCheck soon
- 3377Head Tail Light - open circuitOpen circuitCheck soon
- 3378Head Tail Light - short to batteryShorted highCheck soon
- 3379Hour Meter - short to groundShorted lowCheck soon
- 4310No alternator outputOtherCheck soon
- 33279Glowplug - open circuitOpen circuitCheck soon
- 33280Glowplug - short to batteryShorted highCheck soon
- 33281Glowplug - short to groundShorted lowCheck soon
Other JLG codes: Electrical
Related on Equipments Finder
Source
JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
This source lists 445 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.