JLG · Engine
JLG Fault Code 4310
No alternator output
What does JLG code 4310 mean?
The engine has been running for 15 seconds or more and battery voltage is still under 12.5 V, so the alternator is not charging. The battery will run flat if the machine keeps running. Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage with the engine running; it should rise above rest voltage if the alternator is charging.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure battery voltage with the engine running; it should rise above rest voltage if the alternator is charging
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Alternator belt slipping or broken
- Alternator failed internally
- Alternator excitation wire open
- Battery cables or the main ground loose or corroded
How it failed
You'll notice: The battery does not charge with the engine running.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs
- 3375Generator/welder - short to batteryShorted highCheck soon
- 3376Head Tail Light - short to groundShorted lowCheck soon
- 3377Head Tail Light - open circuitOpen circuitCheck soon
- 3378Head Tail Light - short to batteryShorted highCheck soon
- 3379Hour Meter - short to groundShorted lowCheck soon
- 4310No alternator outputOtherCheck soon
- 33279Glowplug - open circuitOpen circuitCheck soon
- 33280Glowplug - short to batteryShorted highCheck soon
- 33281Glowplug - short to groundShorted lowCheck soon
Show the other 12 codesHide the other codes
- 3-1Contactor did not closeOtherCheck soon
- 3-2Contactor did not openOtherCheck soon
- 4-4Battery supply problemOtherCheck soon
- 441Battery voltage too low - system shutdownShorted lowStop now
- 442Battery voltage too high - system shutdownShorted highStop now
- 445Battery voltage low (warning)Shorted lowCheck soon
- 3311Ground Alarm - short to batteryShorted highCheck soon
- 3362Start Solenoid - short to groundShorted lowCheck soon
- 3363Start Solenoid - open circuitOpen circuitCheck soon
- 3364Start Solenoid - short to batteryShorted highCheck soon
- 3373Generator/welder - short to groundShorted lowCheck soon
- 3374Generator/welder - open circuitOpen circuitCheck soon
Other JLG codes: Engine
Related on Equipments Finder
Source
JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
This source lists 4310 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.