JLG Battery, contactors, starting, generator, lights and alarm outputs fault codes
This family covers the electrical supply and the auxiliary outputs: battery and charging voltage, the main contactors, the start solenoid and glow plug outputs, the generator and welder enable, and the lights, alarm and hour meter outputs. Each is monitored by the module for voltage, short or open circuit.
Where this code shows
Turn the key on and watch the fault lamp or platform display.
What do these codes mean?
JLG codes 3-1 to 33281 are all about the battery, contactors, starting, generator, lights and alarm outputs. The most common failure type is shorted low (7 of 21); 2 need an immediate stop. Start with this check: check battery voltage at rest and while cranking, and the main ground.
How urgent are they?
2 of 21 codes here mean stop now; the other 19 can wait until the shift ends, but find the cause before the next one.
- Stop now2
- Check soon19
What should I check first?
Check battery voltage at rest and while cranking, and the main ground
Shared checks21 of 21
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Battery voltage too low1 code
JLG 441Battery voltage too low: System shutdown
Battery voltage dropped below about 9 V and the system shuts down. The operator sees the machine die or refuse to start, often when cranking.· Shorted lowShorted lowStop nowCauses
- Flat or failing battery that collapses under cranking load
- Poor battery terminal or main ground connection
- Alternator failed so the battery drains while running
- Heavy parasitic load or a short drawing the battery down
- Corroded or damaged main power cable
Checks
- 1Measure battery voltage at rest and while cranking; charge or replace the battery if it falls sharply
- 2Clean and tighten the battery terminals, main cables and chassis ground
- 3Run the engine and check the alternator output voltage at the battery
- 4Check for a parasitic draw by measuring current with the key off
- 5Replace damaged cables and load-test the battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Battery voltage too high1 code
JLG 442Battery voltage too high: System shutdown
Battery voltage is above about 16 V and the system shuts down to protect the electronics. The EMS has to be recycled to clear it.· Shorted highShorted highStop nowCauses
- Alternator regulator failed so it overcharges
- Wrong battery or charger connected, or a booster left on
- Loose sense wire at the alternator letting voltage run high
- Battery disconnect or cable fault causing voltage spikes
Checks
- 1Measure the voltage at the battery with the engine running to see if the alternator is overcharging
- 2Check any external charger or jump source has been removed
- 3Check the alternator sense and regulator wiring at its connector
- 4Replace the alternator or regulator if the voltage stays high
- 5Recycle the EMS and run the machine to confirm the fault does not return
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Ground Alarm1 code
JLG 3311Ground Alarm: Short to battery
The controller reads battery voltage on the ground alarm output while it is commanded off, so the circuit is shorted to battery. EMS must be recycled to clear it.· Shorted highShorted highCheck soonCauses
- Two harness legs bundled so tightly that a worn spot joins them
- Alarm output wire touching a horn or lamp feed, so the alarm sounds with nothing moving
- Melted insulation along the chassis where the alarm wire is clipped to other supply feeds
- Corrosion between pins in the plug (the alarm connector is exposed on the chassis and fills with road dirt and spray)
Checks
- 1With the load off at the ground station and chassis and the key on, any reading on the output wire is the short
- 2Trace the wire alongside any supply wire and look for a touch point along the chassis where the alarm wire is clipped to other supply feeds
- 3Watch the analyzer output as you move a function and listen for the alarm to sound and stop
- 4Disconnect the alarm and key on; if the sounding stops the output is clean and the alarm unit or its feed is the problem
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Start Solenoid3 codes
JLG 3362Start Solenoid: Short to ground
The controller sees the start solenoid output pulled low while it is commanded on, so the circuit is shorted to ground. EMS must be recycled to clear it.· Shorted lowShorted lowCheck soonCauses
- Coil winding rubbing its own case until it earths
- Start solenoid wire shorted to engine metal at a terminal, which can blow the starter fuse
- Wire chafed through to the frame at the engine starter where vibration and heat break wires at the terminals
- Dirt and water bridging a pin to ground; the starter connector sits on the engine, where heat and vibration loosen the terminals
Checks
- 1Pull the plug on the starter at the engine and recycle EMS to see whether the code stays
- 2Meter the signal wire to the frame, flexing it at the engine starter where vibration and heat break wires at the terminals for a reading that comes and goes
- 3Turn the key to start and listen for the starter solenoid click and the starter engaging; the analyzer output should go to supply, not stay at zero
- 4Check the starter fuse and fusible link before anything else; a blown fuse often goes with this code
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JLG 3363Start Solenoid: Open circuit
The controller drives the start solenoid output but feedback shows an open circuit (feedback reads high while the output is off). That function will not work; EMS must be recycled to clear it.· Open circuitOpen circuitCheck soonCauses
- Start solenoid relay or load burnt out or open
- Starter solenoid coil or its small feed wire open, so the starter never engages
- Lead stretched or kinked until it broke at the engine starter where vibration and heat break wires at the terminals
- Terminal worn loose in its housing (the starter connector sits on the engine, where heat and vibration loosen the terminals)
Checks
- 1Ohm the relay or load on the starter at the engine with the plug off and compare with a matching good coil
- 2Check continuity from the module output pin to the plug, wiggling the wire as you test, starting at the engine starter where vibration and heat break wires at the terminals
- 3Command the output from the analyzer and turn the key to start and listen for the starter solenoid click and the starter engaging
- 4Turn the key to start and listen: a click means the solenoid is working and the heavy circuit is the problem, silence means the small circuit is open
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JLG 3364Start Solenoid: Short to battery
The controller reads battery voltage on the start solenoid output while it is commanded off, so the circuit is shorted to battery. EMS must be recycled to clear it.· Shorted highShorted highCheck soonCauses
- Insulation worn between the signal and a supply feed
- Start solenoid wire touching a live feed, so the starter can engage or stay engaged after the engine fires
- Melted insulation at the engine starter where vibration and heat break wires at the terminals
- Wet plug bridging the signal pin to supply, since the starter connector sits on the engine, where heat and vibration loosen the terminals
Checks
- 1With the start solenoid plug off on the starter at the engine and the key on, measure the output wire to ground; any voltage means a short to supply
- 2Look for a wire crossing a live feed at the engine starter where vibration and heat break wires at the terminals, and separate or replace it
- 3Watch the analyzer output as you turn the key to start and listen for the starter solenoid click and the starter engaging
- 4Do not crank until the wire is cleared; with the plug off and key on, voltage on the wire is the short
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Generator/welder3 codes
JLG 3373Generator/welder: Short to ground
The controller sees the generator/welder output pulled low while it is commanded on, so the circuit is shorted to ground. EMS must be recycled to clear it.· Shorted lowShorted lowCheck soonCauses
- Coil insulation failed, leaking to the body
- Generator enable relay coil or its wire shorted to the frame near the generator
- Signal wire rubbed bare on metal near the generator and engine where heat and belt dust build up
- Wet or corroded plug, since the enable relay plug sits near the generator, where belt dust and heat build up
Checks
- 1Pull the plug at the generator on the chassis and recycle EMS to see whether the code stays
- 2Meter between the signal pin and chassis with the plug apart; a reading shows the earth path, probably near the generator and engine where heat and belt dust build up
- 3With the analyzer open, switch the generator on with the engine running and listen for the enable relay click and watch the output state
- 4Check the relay base and the wire under the generator cover for rub marks and heat
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JLG 3374Generator/welder: Open circuit
The controller drives the generator/welder output but feedback shows an open circuit (feedback reads high while the output is off). That function will not work; EMS must be recycled to clear it.· Open circuitOpen circuitCheck soonCauses
- Broken internal lead in the relay or load
- Enable relay coil open, so the generator never connects to its outlet when selected
- Wire work-hardened and snapped inside its sheath near the generator and engine where heat and belt dust build up
- Corroded or open terminal in the plug; the enable relay plug sits near the generator, where belt dust and heat build up
Checks
- 1Read the coil resistance at the connector at the generator on the chassis; no reading means a burnt winding
- 2Check continuity from the module output pin to the plug, wiggling the wire as you test, starting near the generator and engine where heat and belt dust build up
- 3Command the output from the analyzer and switch the generator on with the engine running and listen for the enable relay click
- 4Swap in a known good relay of the same type to see whether the generator output comes back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JLG 3375Generator/welder: Short to battery
The controller reads battery voltage on the generator/welder output while it is commanded off, so the circuit is shorted to battery. EMS must be recycled to clear it.· Shorted highShorted highCheck soonCauses
- Insulation worn between the signal and a supply feed
- Enable wire touching a supply feed so the generator or welder is held on
- Harness rubbed bare and touching a feed near the generator and engine where heat and belt dust build up
- Water tracking between supply and signal pins (the enable relay plug sits near the generator, where belt dust and heat build up)
Checks
- 1Check for supply on the output wire at the open connector at the generator on the chassis
- 2Look for a wire crossing a live feed near the generator and engine where heat and belt dust build up, and separate or replace it
- 3Watch the analyzer output as you switch the generator on with the engine running and listen for the enable relay click
- 4Switch the generator off at the control and check whether the output stays live; any voltage on the wire is the short
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Head Tail Light3 codes
JLG 3376Head Tail Light: Short to ground
The controller sees the head tail light output pulled low while it is commanded on, so the circuit is shorted to ground. EMS must be recycled to clear it.· Shorted lowShorted lowCheck soonCauses
- Coil insulation failed, leaking to the body
- Light relay coil or its wire shorted to the chassis, usually where the lamp harness is pinched
- Signal wire rubbed bare on metal along the chassis near the lamps, where the light harness is often cut by accident
- Wet or corroded plug, since the light relay plug is on the chassis, where it is often unplugged during repairs and left loose
Checks
- 1Unplug the head/tail light at the light relay on the chassis; if the code clears the relay or load is the short, if not the wiring or module is
- 2Meter the signal wire to the frame, flexing it along the chassis near the lamps, where the light harness is often cut by accident for a reading that comes and goes
- 3With the analyzer open, switch the lights on and off and listen for the relay click and watch the output state
- 4Look at the lamp harness for pinched or cut sections beside the lamps and relay
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JLG 3377Head Tail Light: Open circuit
The controller drives the head tail light output but feedback shows an open circuit (feedback reads high while the output is off). That function will not work; EMS must be recycled to clear it.· Open circuitOpen circuitCheck soonCauses
- Broken internal lead in the relay or load
- Light relay coil open or its small feed wire broken, so the lights never switch on
- Conductor snapped in the harness along the chassis near the lamps, where the light harness is often cut by accident
- Terminal worn loose in its housing (the light relay plug is on the chassis, where it is often unplugged during repairs and left loose)
Checks
- 1Ohm the relay or load at the light relay on the chassis with the plug off and compare with a matching good coil
- 2Test both wires with the plug off and flex them along the chassis near the lamps, where the light harness is often cut by accident to catch a hidden break
- 3Switch the lights on and off and listen for the relay click; the analyzer should show the module sending the command
- 4Check the lamp fuse and then swap the relay with a known good one
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JLG 3378Head Tail Light: Short to battery
The controller reads battery voltage on the head tail light output while it is commanded off, so the circuit is shorted to battery. EMS must be recycled to clear it.· Shorted highShorted highCheck soonCauses
- Two harness legs bundled so tightly that a worn spot joins them
- Light relay wire touching a lamp feed, so the lights are held on
- Chafed insulation along the chassis near the lamps, where the light harness is often cut by accident letting a feed touch the output wire
- Wet plug bridging the signal pin to supply, since the light relay plug is on the chassis, where it is often unplugged during repairs and left loose
Checks
- 1With the head/tail light plug off at the light relay on the chassis and the key on, measure the output wire to ground; any voltage means a short to supply
- 2Trace the wire alongside any supply wire and look for a touch point along the chassis near the lamps, where the light harness is often cut by accident
- 3Watch the analyzer output as you switch the lights on and off and listen for the relay click
- 4Pull the relay and see whether the lights still come on, which would point at the lamp feed itself
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hour Meter1 code
JLG 3379Hour Meter: Short to ground
The controller sees the hour meter output pulled low while it is commanded on, so the circuit is shorted to ground. EMS must be recycled to clear it.· Shorted lowShorted lowCheck soonCauses
- Hour meter relay or load shorted to its case
- Hour meter output wire shorted to the panel frame behind the control box
- Signal wire rubbed bare on metal behind the ground control panel, where the meter wire is pinched by panel screws
- Wet or corroded plug, since the meter plug sits behind the control panel where it can be knocked loose
Checks
- 1Disconnect the load at the ground station panel; the code staying means a harness or module fault
- 2Look for rub marks on the harness behind the ground control panel, where the meter wire is pinched by panel screws and test any suspect length to earth
- 3With the analyzer open, run the engine and see whether the meter counts and watch the output state
- 4Remove the meter and look at the back of the panel for screws pinching the lead
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Glowplug3 codes
JLG 33279Glowplug: Open circuit
The controller drives the glowplug output but feedback shows an open circuit (feedback reads high while the output is off). That function will not work; EMS must be recycled to clear it.· Open circuitOpen circuitCheck soonCauses
- Coil gone open from heat or age
- Glow plug relay coil or its feed open, so the cylinders are not warmed and cold starting is hard
- Wire work-hardened and snapped inside its sheath on the engine where the glow plug feed carries heavy current
- Terminal pushed back or plug not latched, since the glow plug feed connector is at the engine, where the heavy current heats and loosens the terminals
Checks
- 1Check the coil on the diesel engine for an open winding, comparing with a good one if you have it
- 2Test both wires with the plug off and flex them on the engine where the glow plug feed carries heavy current to catch a hidden break
- 3Turn the key on and listen for the glow plug relay to click and the feed to heat; the analyzer should show the module sending the command
- 4Turn the key on and listen for the glow relay to click; no click on a cold engine points at the coil circuit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JLG 33280Glowplug: Short to battery
The controller reads battery voltage on the glowplug output while it is commanded off, so the circuit is shorted to battery. EMS must be recycled to clear it.· Shorted highShorted highCheck soonCauses
- Lead rubbed through against a live cable
- Glow plug output touching a feed so the glow plugs stay heated and may burn out
- Damaged sheath on the engine where the glow plug feed carries heavy current, exposing the wire to a live one
- Water tracking between supply and signal pins (the glow plug feed connector is at the engine, where the heavy current heats and loosens the terminals)
Checks
- 1Check for supply on the output wire at the open connector on the diesel engine
- 2Inspect the harness for bare spots, burnt insulation and melted clamps, especially on the engine where the glow plug feed carries heavy current
- 3Retest after the repair: turn the key on and listen for the glow plug relay to click and the feed to heat
- 4Check the glow plug feed with the key off: supply there means the relay output is held on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JLG 33281Glowplug: Short to ground
The controller sees the glowplug output pulled low while it is commanded on, so the circuit is shorted to ground. EMS must be recycled to clear it.· Shorted lowShorted lowCheck soonCauses
- Coil winding rubbing its own case until it earths
- Glow plug relay output shorted to engine metal at the feed terminal
- Harness pinched against the frame on the engine where the glow plug feed carries heavy current
- Damaged plug seal, which matters because the glow plug feed connector is at the engine, where the heavy current heats and loosens the terminals
Checks
- 1Disconnect the load on the diesel engine; the code staying means a harness or module fault
- 2Meter the signal wire to the frame, flexing it on the engine where the glow plug feed carries heavy current for a reading that comes and goes
- 3Watch the output on the analyzer as you turn the key on and listen for the glow plug relay to click and the feed to heat
- 4Inspect the glow plug feed terminal for burnt insulation touching the engine
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Other codes5 codes
JLG 3-1Contactor did not close
The controller switched a contactor on but the feedback shows it never closed. The affected function (engine start, pump or aux power) stays off until the cause is found. The manual lists this flash code without extra Help text.· OtherOtherCheck soonCauses
- Contactor coil open or burnt out
- Loose, corroded or burnt power terminals on the contactor
- Harness to the contactor coil broken or pulled out of its connector
- Missing ground or supply to the coil from the module output
Checks
- 1Read the analyzer message to see which contactor is named, then check its output in the diagnostics screen while commanding it on
- 2Listen and feel at the contactor when it is commanded on; no click points to the coil or its supply, a click with no function points to the contacts
- 3Measure the voltage at the coil terminals while it is commanded on; it should be battery supply (12/24 V depending on the machine)
- 4With the coil disconnected, ohm it and compare with a matching contactor; an open coil needs replacing
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 3-2Contactor did not open
The controller switched a contactor off but the feedback says it is still closed. Because a contactor may be stuck on, the system may leave a function powered. The manual lists this flash code without extra Help text.· OtherOtherCheck soonCauses
- Contactor contacts welded together by arcing
- Contactor sticking mechanically after heat or contamination
- Coil wire shorted to a supply wire so it never drops out
- Module output driver stuck on
Checks
- 1Read the analyzer message to identify the contactor, then turn the key off and check whether the function still has power
- 2With the machine off and battery isolated, measure across the contactor power terminals; a reading near zero with the coil de-energised means welded contacts
- 3Unplug the coil connector and check whether the contactor drops out; if it does, the problem is in the wiring or module output
- 4Check the coil wire for a short to a supply wire along the harness and at the connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 4-4Battery supply problem
Battery voltage is outside the controller's limits. Under 11 V for over 5 s gives a warning only (BATTERY LOW). Under 9 V shuts the system down; above 16 V also shuts it down and needs an EMS recycle.· OtherOtherCheck soonCauses
- Weak or discharged starting battery
- Loose or corroded battery terminals or main ground
- Alternator undercharging or overcharging (regulator failed)
- Voltage drop in the supply wire to the ground module
Checks
- 1Measure battery voltage at rest and while cranking
- 2Clean and tighten the terminals and the frame ground
- 3Run the engine and check the charge voltage is roughly 13.5-14.5 V on a 12 V machine
- 4Check voltage at the ground module supply pins
- 5Load test the battery and replace it if it will not hold voltage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 445Battery voltage low (warning)
Battery voltage is below about 11 V for over 5 seconds, not counting cranking. The controller keeps running but it is warning that the battery is weak.· Shorted lowShorted lowCheck soonCauses
- Weak or old battery that will not hold charge
- Alternator undercharging because of a slipping belt or bad output
- Loose or corroded terminals dropping voltage under load
- Large load left on, such as lights or accessories
Checks
- 1Measure battery voltage at rest and with the engine running
- 2Charge the battery fully and load-test it, replacing it if it will not hold charge
- 3Check the alternator output and belt condition
- 4Clean and tighten battery terminals and ground connections
- 5Look for accessories drawing too much current
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JLG 4310No alternator output
The engine has been running for 15 seconds or more and battery voltage is still under 12.5 V, so the alternator is not charging. The battery will run flat if the machine keeps running.· OtherOtherCheck soonCauses
- Alternator belt slipping or broken
- Alternator failed internally
- Alternator excitation wire open
- Battery cables or the main ground loose or corroded
Checks
- 1Measure battery voltage with the engine running; it should rise above rest voltage if the alternator is charging
- 2Check the belt for condition and tension and look at the pulley for slipping
- 3Check the alternator excitation and output wires for continuity and tight connections
- 4Clean and tighten battery cables and the engine ground
- 5Replace the alternator if the output stays low with the belt and wiring good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check battery voltage at rest and while cranking, and the main ground
- 2Clean and tighten the battery and ground terminals
- 3Command the output from the analyzer and listen or look for the load to operate
- 4Meter the output wire for a short to supply or ground and for continuity
- 5Replace the failed relay, solenoid or load and recheck
Causes
- Low or unstable battery voltage, poor ground or loose terminal
- Contactor, solenoid or relay failed
- Output wire shorted or open at its load
- Module output driver damaged
Most common here: shorted low (7 of 21)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The machine will not start or loses power, or an accessory such as the lights, alarm or generator does not work, and the code names the output or supply.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
- JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.