EF Logo

Deutz · Exhaust aftertreatment (SCR)

Deutz DEF pump, metering unit and suction unit fault codes

The parts that move and dose DEF: the DEF pump with its reverse valve and pump temperature (SPN 4375), the DEF metering unit and dosing valve (SPN 3361), and the DEF suction unit hardware in the tank. Each code names the part and whether its drive, its feedback or its movement failed.

FaultCheckSPN 3361FMI 4Deutz · DEF metering unit
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 3361 FMI 3 to SPN 524282 FMI 11 are all about the dEF pump, metering unit and suction unit. The most common failure type is shorted low (4 of 22); none needs an immediate stop. Start with this check: listen for the pump at the start of a dosing test and read its status in SerDia.

How urgent are they?

None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.

  • Check soon22

What should I check first?

Listen for the pump at the start of a dosing test and read its status in SerDia

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF metering unit4 codes

    • Deutz SPN 3361 FMI 3DEF metering unit: Voltage high / shorted high

      The EMR4 sees the output for the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF metering valve (dosing valve) shorted internally

      Checks

      1. 1Unplug the DEF metering valve (dosing valve): if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF metering unit - Voltage above normal or shorted to high source

    • Deutz SPN 3361 FMI 4DEF metering unit: Voltage low / shorted low

      The EMR4 sees the output for the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Water in the connector bridging the pins
      • DEF metering valve (dosing valve) winding shorted to its housing
      • Dosing nozzle blocked by crystallised DEF

      Checks

      1. 1Check the dosing valve for crystal deposits at the nozzle and for a spray pattern during a dosing test
      2. 2Measure the valve coil resistance and check wiring for heat damage
      3. 3Unplug the DEF metering valve (dosing valve): if the code changes, the part is the shorted one; if it stays, look at the harness
      4. 4Measure the winding resistance of the part and look for a very low value
      5. 5With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF metering unit - Voltage below normal or shorted to low source

      Full page for SPN 3361 FMI 4
    • Deutz SPN 3361 FMI 6DEF metering unit: Current high / grounded

      The EMR4 sees too much current through the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF).· Shorted low
      Check soon

      Causes

      • Valve needle stuck by crystallised DEF
      • Winding partly shorted inside the part
      • Dosing nozzle blocked by crystallised DEF

      Checks

      1. 1Check the dosing valve for crystal deposits at the nozzle and for a spray pattern during a dosing test
      2. 2Measure the DEF metering valve (dosing valve) winding resistance; a low value means it is shorting
      3. 3Measure the valve coil resistance and check wiring for heat damage
      4. 4Check the wiring for chafe and for water in the connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF metering unit - Current above normal or grounded circuit

    • Deutz SPN 3361 FMI 7DEF metering unit: Not responding / out of adjustment

      The EMR4 sees the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • Dosing nozzle blocked by crystallised DEF
      • Valve coil shorted from heat damage
      • Valve needle stuck by crystallised DEF

      Checks

      1. 1Measure the valve coil resistance and check wiring for heat damage
      2. 2Inspect for soot, oil or foreign matter around the part
      3. 3Move the part by hand with the key off to see whether it is stuck
      4. 4Command it from SerDia and watch actual position against commanded
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF metering unit - Mechanical system not responding or out of adjustment

  • DEF metering valve2 codes

    • Deutz SPN 4374 FMI 13DEF metering valve: Out of calibration

      The EMR4 reports the DEF metering valve (at the exhaust pipe in front of the SCR catalyst, injecting DEF) as out of calibration.· Part or controller
      Check soon

      Causes

      • DEF metering valve replaced without a recalibration
      • Mechanical wear or play shifting the end positions

      Checks

      1. 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the DEF metering valve
      2. 2Check the DEF metering valve for mechanical play or a loose linkage that shifts its end positions
      3. 3Replace the DEF metering valve if the end-position learn routine in SerDia fails repeatedly
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Deutz SPN 524141 FMI 7DEF metering valve: Not responding / out of adjustment

      The EMR4 sees the DEF metering valve (at the exhaust pipe in front of the SCR catalyst, injecting DEF) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • Valve needle stuck by crystallised DEF
      • Failed part or a real condition behind the signal

      Checks

      1. 1Move the part by hand with the key off to see whether it is stuck
      2. 2Command it from SerDia and watch actual position against commanded
      3. 3Inspect for soot, oil or foreign matter around the part
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF metering valve - Mechanical system not responding or out of adjustment

  • DEF pump3 codes

    • Deutz SPN 4375 FMI 3DEF pump: Voltage high / shorted high

      The EMR4 sees the output for the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • DEF pump shorted internally
      • Connector pin touching a live pin

      Checks

      1. 1Measure the winding or coil resistance of the part
      2. 2Unplug the DEF pump: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      3. 3Listen for the pump running at key-on and check DEF pressure in SerDia
      4. 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF pump - Voltage above normal or shorted to high source

      Full page for SPN 4375 FMI 3
    • Deutz SPN 4375 FMI 4DEF pump: Voltage low / shorted low

      The EMR4 sees the output for the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Pump motor worn or blocked by crystals
      • Output wire chafed to ground or the engine block
      • DEF pump winding shorted to its housing

      Checks

      1. 1Inspect the dosing module connector and lines for urea crystals
      2. 2Unplug the DEF pump: if the code changes, the part is the shorted one; if it stays, look at the harness
      3. 3Listen for the pump running at key-on and check DEF pressure in SerDia
      4. 4Measure the winding resistance of the part and look for a very low value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF pump - Voltage below normal or shorted to low source

    • Deutz SPN 4375 FMI 5DEF pump: Current low / open circuit

      The EMR4 sees too little current through the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • Connector left unplugged after earlier work
      • DEF pump winding open

      Checks

      1. 1Inspect both ends of the DEF pump circuit (EMR4 plug and part connector) for pins pushed back in the housing
      2. 2Inspect the dosing module connector and lines for urea crystals
      3. 3Continuity-test each wire to the matching EMR4 pin
      4. 4Measure the resistance across the DEF pump terminals: infinity means an open winding
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - DEF pump - Current below normal or open circuit

  • DEF reverse valve4 codes

    • Deutz SPN 4376 FMI 3DEF reverse valve: Voltage high / shorted high

      The EMR4 sees the output for the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF reverse valve shorted internally
      • Valve coil open or shorted

      Checks

      1. 1Check the reverse valve coil resistance against the machine maker spec
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4Look for crystallised urea around the valve and connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF reverse valve - Voltage above normal or shorted to high source

    • Deutz SPN 4376 FMI 4DEF reverse valve: Voltage low / shorted low

      The EMR4 sees the output for the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • DEF reverse valve winding shorted to its housing
      • Valve coil open or shorted
      • Water in the connector bridging the pins

      Checks

      1. 1Look for crystallised urea around the valve and connector
      2. 2Unplug the DEF reverse valve: if the code changes, the part is the shorted one; if it stays, look at the harness
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      5. 5Check the reverse valve coil resistance against the machine maker spec
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF reverse valve - Voltage below normal or shorted to low source

    • Deutz SPN 4376 FMI 5DEF reverse valve: Current low / open circuit

      The EMR4 sees too little current through the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Connector left unplugged after earlier work
      • Broken wire or a pin pushed out of the connector
      • Valve coil open or shorted

      Checks

      1. 1Measure the resistance across the DEF reverse valve terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Look for crystallised urea around the valve and connector
      4. 4Check the reverse valve coil resistance against the machine maker spec
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - DEF reverse valve - Current below normal or open circuit

    • Deutz SPN 4376 FMI 12DEF reverse valve: Bad device or component

      The EMR4 judges the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the DEF reverse valve
      • Water or soot inside the part
      • Driver stage in the EMR4 failing

      Checks

      1. 1Read the DEF reverse valve status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the DEF reverse valve connector with the key on to confirm the part is powered
      3. 3Fit a known good DEF reverse valve if you can borrow one and see whether the code clears for good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF reverse valve - Bad intelligent device or component

  • Hardware failure temperature sensor DEF suction unit2 codes

    • Deutz SPN 523668 FMI 11Hardware failure temperature sensor DEF suction unit: Root cause not known

      The EMR4 logged a fault on the hardware failure temperature sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524282 FMI 11Hardware failure temperature sensor DEF suction unit: Root cause not known

      The EMR4 logged a fault on the hardware failure temperature sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Hardware failure quality sensor DEF suction unit1 code

    • Deutz SPN 523669 FMI 11Hardware failure quality sensor DEF suction unit: Root cause not known

      The EMR4 logged a fault on the hardware failure quality sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Hardware failure level sensor DEF suction unit1 code

    • Deutz SPN 523670 FMI 11Hardware failure level sensor DEF suction unit: Root cause not known

      The EMR4 logged a fault on the hardware failure level sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Heater DEF metering unit2 codes

    • Deutz SPN 523720 FMI 2Heater DEF metering unit: Erratic reading

      The EMR4 sees the heater DEF metering unit (at the exhaust pipe in front of the SCR catalyst, injecting DEF) behave erratically against the command, which can mean a sticking part or an intermittent connection.· Erratic or implausible
      Check soon

      Causes

      • Valve needle stuck by crystallised DEF
      • Intermittent contact in the connector

      Checks

      1. 1Command the heater DEF metering unit from SerDia and watch actual versus commanded behaviour for lag or dropouts
      2. 2Wiggle the heater DEF metering unit harness and connector while watching the live status in SerDia for dropouts
      3. 3Check both connector halves of the heater DEF metering unit for loose, bent or fretted pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Heater DEF metering unit - Data erratic intermittent or incorrect

    • Deutz SPN 523720 FMI 8Heater DEF metering unit: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the heater DEF metering unit (at the exhaust pipe in front of the SCR catalyst, injecting DEF).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the heater DEF metering unit value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Heater DEF metering unit - Abnormal frequency or pulse width or period

  • DEF pump temperature3 codes

    • Deutz SPN 524067 FMI 0DEF pump temperature: Reading too high· most severe

      The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) above its allowed range.· Real condition
      Check soon

      Causes

      • Part driven beyond its limit
      • Pump seized by crystallised DEF

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the DEF pump temperature moves freely through its range by hand with the key off
      3. 3Inspect the supply and control wiring of the DEF pump temperature for chafe, water and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pump temperature - Data above normal operational range (Most severe level)

    • Deutz SPN 524067 FMI 1DEF pump temperature: Reading too low· most severe

      The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) below its allowed range.· Real condition
      Check soon

      Causes

      • Part not reaching its commanded value
      • Pump seized by crystallised DEF

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the part moves through its full travel by hand with the key off
      3. 3Inspect the supply and control wiring of the DEF pump temperature for chafe, water and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pump temperature - Data below normal operational range (Most severe level)

    • Deutz SPN 524067 FMI 2DEF pump temperature: Erratic reading

      The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) behave erratically against the command, which can mean a sticking part or an intermittent connection.· Erratic or implausible
      Check soon

      Causes

      • Pump seized by crystallised DEF
      • Intermittent contact in the connector

      Checks

      1. 1Command the DEF pump temperature from SerDia and watch actual versus commanded behaviour for lag or dropouts
      2. 2Wiggle the DEF pump temperature harness and connector while watching the live status in SerDia for dropouts
      3. 3Check both connector halves of the DEF pump temperature for loose, bent or fretted pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF pump temperature - Data erratic intermittent or incorrect

Shared checks

Checks, in order

  1. 1Listen for the pump at the start of a dosing test and read its status in SerDia
  2. 2Measure the coil resistance of the pump motor and the metering valve
  3. 3Check the DEF lines and the suction filter for blockage and crystals
  4. 4Inspect the connectors for crystallised DEF and corrosion

Causes

  • DEF pump failed, frozen or blocked by crystals
  • Metering valve stuck or its coil open or shorted
  • Suction line or filter in the tank blocked
  • Connector corroded by DEF

Most common here: shorted low (4 of 22)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: A warning lamp or limited function.

Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.