EF Logo

Deutz · Exhaust aftertreatment (SCR)

Deutz DEF pressure and DEF tank level fault codes

The DEF pressure sensor in the dosing line and the DEF tank level sensor. The EMR4 uses the pressure to confirm the pump builds pressure before dosing, and the level to warn of an empty tank.

More about these parts

Each code names the sensor and whether the reading is out of range, shorted, open or implausible.

FaultCheckSPN 1761FMI 0Deutz · DEF tank level sensor
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 1761 FMI 0 to SPN 524178 FMI 7 are all about the dEF pressure and DEF tank level. The most common failure type is real condition (8 of 21); none needs an immediate stop. Start with this check: read the DEF pressure in SerDia with the pump off and during a dosing test.

How urgent are they?

None of the 21 codes here means stop now; 20 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon20
  • Info1

What should I check first?

Read the DEF pressure in SerDia with the pump off and during a dosing test

Shared checks

21 of 21

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF tank level sensor7 codes

    • Deutz SPN 1761 FMI 0DEF tank level sensor: Reading too high· most severe

      The DEF tank level sensor (in the DEF tank unit) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • DEF tank level sensor drifting high or reading with an offset
      • Hose or port feeding the sensor blocked with dirt

      Checks

      1. 1Check the real value against a mechanical gauge or second reading before touching the DEF tank level sensor
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port or hose for restriction
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF tank level sensor - Data above normal operational range (Most severe level)

    • Deutz SPN 1761 FMI 1DEF tank level sensor: Reading too low· most severe

      The DEF tank level sensor (in the DEF tank unit) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • DEF tank level sensor drifting low or reading with an offset
      • Hose or port feeding the sensor split or disconnected

      Checks

      1. 1Check the real value with a mechanical gauge before replacing the DEF tank level sensor
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port, hose and seal for leaks
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF tank level sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 1761 FMI 2DEF tank level sensor: Erratic reading

      The EMR4 sees the DEF tank level sensor (in the DEF tank unit) signal jump or disagree with other values.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector
      • Harness chafed against a bracket in a spot that only touches under vibration
      • DEF tank level sensor on its way out

      Checks

      1. 1Watch the DEF tank level sensor value in SerDia while wiggling the connector and harness
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the 5 V reference for dips while the fault shows
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF tank level sensor - Data erratic intermittent or incorrect

    • Deutz SPN 1761 FMI 14DEF tank level sensor: Special instructions

      The EMR4 flags the DEF tank level sensor (in the DEF tank unit) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 3532 FMI 3DEF tank level sensor: Voltage high / shorted high

      The EMR4 reads the DEF tank level sensor (in the DEF tank unit) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • DEF tank level sensor failed high
      • Tank unit connector corroded
      • Open ground return wire, which pushes the signal up to the reference

      Checks

      1. 1Key on: measure the 5 V reference at the DEF tank level sensor plug between supply and ground; 5 V present means the supply side is fine
      2. 2With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      3. 3Fit a known good DEF tank level sensor temporarily, if you have one, and see whether the reading moves back into range
      4. 4Compare the DEF tank level sensor reading in SerDia with key on and engine off against the value you expect at rest
      5. 5Check continuity of the sensor ground wire back to the EMR4 pin
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF tank level sensor - Voltage above normal or shorted to high source

    • Deutz SPN 3532 FMI 4DEF tank level sensor: Voltage low / shorted low

      The EMR4 reads the DEF tank level sensor (in the DEF tank unit) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to ground
      • 5 V reference lost: open supply wire or a short on the shared 5 V line
      • DEF tank level sensor failed low
      • Tank unit connector corroded

      Checks

      1. 1Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
      2. 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      3. 3Compare the DEF tank level sensor reading in SerDia with key on and engine off against the value you expect at rest
      4. 4Key on: measure the 5 V reference at the DEF tank level sensor plug; no reference means open supply wire or another sensor on that line pulling it down
      5. 5Fit a known good DEF tank level sensor temporarily, if you have one, and see whether the reading moves back into range
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF tank level sensor - Voltage below normal or shorted to low source

    • Deutz SPN 3532 FMI 13DEF tank level sensor: Out of calibration

      The EMR4 reports the DEF tank level sensor (in the DEF tank unit) as out of calibration.· Part or controller
      Check soon

      Causes

      • Part replaced without a calibration or learning routine
      • Mechanical wear or play shifting the learned positions

      Checks

      1. 1Run the matching calibration or learn routine with the service tool, if available
      2. 2Check the part for mechanical play or a loose mounting that shifts its readings
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • DEF pump pressure3 codes

    • Deutz SPN 4334 FMI 0DEF pump pressure: Reading too high· most severe

      The DEF pump pressure (in the SCR dosing module, measuring DEF line pressure) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • DEF pump pressure drifting high or reading with an offset
      • Hose or port feeding the sensor blocked with dirt

      Checks

      1. 1Check the real value against a mechanical gauge or second reading before touching the DEF pump pressure
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port or hose for restriction
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pump pressure - Data above normal operational range (Most severe level)

    • Deutz SPN 4334 FMI 1DEF pump pressure: Reading too low· most severe

      The DEF pump pressure (in the SCR dosing module, measuring DEF line pressure) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • DEF pump pressure drifting low or reading with an offset
      • Hose or port feeding the sensor split or disconnected

      Checks

      1. 1Check the real value with a mechanical gauge before replacing the DEF pump pressure
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port, hose and seal for leaks
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pump pressure - Data below normal operational range (Most severe level)

    • Deutz SPN 4334 FMI 2DEF pump pressure: Erratic reading

      The EMR4 sees the DEF pump pressure (in the SCR dosing module, measuring DEF line pressure) signal jump or disagree with other values.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector
      • Harness chafed against a bracket in a spot that only touches under vibration
      • DEF pump pressure on its way out

      Checks

      1. 1Watch the DEF pump pressure value in SerDia while wiggling the connector and harness
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the 5 V reference for dips while the fault shows
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF pump pressure - Data erratic intermittent or incorrect

  • DEF pressure10 codes

    • Deutz SPN 523632 FMI 0DEF pressure: Reading too high· most severe

      The DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • Pressure sensor fouled by urea
      • Real high pressure points to a blocked dosing valve nozzle or blocked return line
      • DEF pressure sensor drifting high or reading with an offset
      • Hose or port feeding the sensor blocked with dirt

      Checks

      1. 1Compare with its neighbouring sensors in SerDia to see whether only this value is off
      2. 2Inspect the sensor port or hose for restriction
      3. 3Compare DEF pressure in SerDia while the pump runs and while it is stopped
      4. 4Check the real value against a mechanical gauge or second reading before touching the DEF pressure sensor
      5. 5Check the DEF supply line for kinks, leaks and frozen sections
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pressure - Data above normal operational range (Most severe level)

    • Deutz SPN 523632 FMI 1DEF pressure: Reading too low· most severe

      The DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • DEF pressure sensor drifting low or reading with an offset
      • Pressure sensor fouled by urea
      • Hose or port feeding the sensor split or disconnected
      • Real low pressure points to an empty or frozen tank, a failed pump, or a leaking line

      Checks

      1. 1Compare DEF pressure in SerDia while the pump runs and while it is stopped
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Check the DEF supply line for kinks, leaks and frozen sections
      4. 4Inspect the sensor port, hose and seal for leaks
      5. 5Check the real value with a mechanical gauge before replacing the DEF pressure sensor
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pressure - Data below normal operational range (Most severe level)

    • Deutz SPN 523632 FMI 3DEF pressure: Voltage high / shorted high

      The EMR4 reads the DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • DEF pressure sensor failed high
      • Open ground return wire, which pushes the signal up to the reference
      • DEF line blocked or leaking

      Checks

      1. 1Compare the DEF pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      2. 2Key on: measure the 5 V reference at the DEF pressure sensor plug between supply and ground; 5 V present means the supply side is fine
      3. 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      4. 4Check continuity of the sensor ground wire back to the EMR4 pin
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF pressure - Voltage above normal or shorted to high source

    • Deutz SPN 523632 FMI 4DEF pressure: Voltage low / shorted low

      The EMR4 reads the DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to ground
      • DEF pressure sensor failed low
      • DEF line blocked or leaking
      • 5 V reference lost: open supply wire or a short on the shared 5 V line

      Checks

      1. 1With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      2. 2Fit a known good DEF pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      3. 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
      4. 4Key on: measure the 5 V reference at the DEF pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
      5. 5Compare the DEF pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF pressure - Voltage below normal or shorted to low source

    • Deutz SPN 523632 FMI 11DEF pressure: Root cause not known

      The EMR4 logged a fault on the DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that did not stay long enough to be classified
      • Failing DEF pressure sensor
      • Poor ground or 5 V supply at the sensor

      Checks

      1. 1Read the full SerDia fault list for a clearer code on the DEF pressure sensor
      2. 2Measure 5 V supply and signal voltage at the sensor plug with the key on
      3. 3Inspect the DEF pressure sensor connector and the harness run for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 523632 FMI 16DEF pressure: Reading too high· moderately severe

      The EMR4 sees the DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) above normal at a moderately severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is above normal, for example a blockage or an overload
      • Sensor reading too high

      Checks

      1. 1Read the DEF pressure sensor value in SerDia and compare it with an independent measurement
      2. 2Look for the real cause of the high value before replacing parts
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pressure - Data above normal operational range (Moderately severe level)

    • Deutz SPN 523632 FMI 18DEF pressure: Reading too low· moderately severe

      The EMR4 sees the DEF pressure sensor (in the SCR dosing module, measuring DEF line pressure) below normal at a moderately severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is below normal, for example a leak or a weak supply
      • Sensor reading too low

      Checks

      1. 1Read the DEF pressure sensor value in SerDia and compare it with an independent measurement
      2. 2Look for the real cause of the low value before replacing parts
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF pressure - Data below normal operational range (Moderately severe level)

    • Deutz SPN 524147 FMI 7DEF pressure: Not responding / out of adjustment

      The EMR4 sees the DEF pressure (in the SCR dosing module, measuring DEF line pressure) not following its command.· Part or controller
      Check soon

      Causes

      • Part stuck or seized by dirt or deposits
      • Linkage or drive worn or disconnected

      Checks

      1. 1Command the DEF pressure from SerDia and compare actual with commanded position or value
      2. 2Move the part by hand with the key off to find out whether it is mechanically stuck
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF pressure - Mechanical system not responding or out of adjustment

    • Deutz SPN 524147 FMI 13DEF pressure: Out of calibration

      The EMR4 reports the DEF pressure (in the SCR dosing module, measuring DEF line pressure) as out of calibration.· Part or controller
      Check soon

      Causes

      • Part replaced without a calibration or learning routine
      • Mechanical wear or play shifting the learned positions

      Checks

      1. 1Run the matching calibration or learn routine with the service tool, if available
      2. 2Check the part for mechanical play or a loose mounting that shifts its readings
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Deutz SPN 524178 FMI 7DEF pressure: Not responding / out of adjustment

      The EMR4 sees the DEF pressure (in the SCR dosing module, measuring DEF line pressure) not following its command.· Part or controller
      Check soon

      Causes

      • Part stuck or seized by dirt or deposits
      • Linkage or drive worn or disconnected

      Checks

      1. 1Command the DEF pressure from SerDia and compare actual with commanded position or value
      2. 2Move the part by hand with the key off to find out whether it is mechanically stuck
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF pressure - Mechanical system not responding or out of adjustment

  • DEF pressure suction line1 code

    • Deutz SPN 524177 FMI 7DEF pressure suction line: Not responding / out of adjustment

      The EMR4 sees the DEF pressure suction line (in the SCR dosing module, measuring DEF line pressure) not following its command.· Part or controller
      Check soon

      Causes

      • Part stuck or seized by dirt or deposits
      • Linkage or drive worn or disconnected

      Checks

      1. 1Command the DEF pressure suction line from SerDia and compare actual with commanded position or value
      2. 2Move the part by hand with the key off to find out whether it is mechanically stuck
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF pressure suction line - Mechanical system not responding or out of adjustment

Shared checks

Checks, in order

  1. 1Read the DEF pressure in SerDia with the pump off and during a dosing test
  2. 2Compare the level sensor reading with the real tank content
  3. 3Check the DEF lines and fittings for leaks and crystals
  4. 4Inspect the sensor connectors for DEF and corrosion

Causes

  • DEF line blocked, frozen or leaking so the real pressure is wrong
  • Pressure or level sensor plug corroded by DEF
  • Level sensor float or probe stuck or failed
  • Pump not building pressure

Most common here: real condition (8 of 21)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A warning lamp or limited function.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.