Cummins DEF line heaters and DEF temperature sensors fault codes

Heated DEF lines carry fluid from the tank to the dosing unit. Additional temperature sensors measure the DEF temperature at the dosing unit and in the supply line.

FaultCheck3237Cummins · DEF line heater 1 circuit
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 3237 to 4745 are all about the dEF line heaters and DEF temperature sensors. The most common failure type is shorted high (5 of 17); none needs an immediate stop. Start with this check: measure the heater resistance at the connector.

How urgent are they?

None of the 17 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon16
  • Info1

What should I check first?

Measure the heater resistance at the connector

Shared checks

17 of 17

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF line heater 1 circuit2 codes

    • Cummins 3237DEF line heater 1 circuit: Voltage high

      The ECM reads the DEF line heater 1 circuit above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the DEF line heater 1 circuit
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the DEF line heater 1 circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the DEF line heater 1 circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the DEF line heater 1 circuit back to the ECM
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 3258DEF line heater 1 circuit: Current low / open circuit

      The ECM sees too little current, or no current, in the DEF line heater 1 circuit.· Open circuit
      Check soon

      Causes

      • Broken or pulled-out wire in the harness to the DEF line heater 1 circuit
      • Connector at the DEF line heater 1 circuit unplugged, loose or with a pin pushed back
      • Burnt-out coil or element in the part itself

      Checks

      1. 1Unplug the DEF line heater 1 circuit and measure the resistance of the part itself against the service manual value, since an infinite reading means the part is open
      2. 2Check continuity of both wires between the DEF line heater 1 circuit connector and the ECM connector
      3. 3Wiggle the harness and connector at the DEF line heater 1 circuit while watching the live status to catch an intermittent open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:DEF line heater 1 circuit - current low or open circuit

  • DEF line heater 2 circuit3 codes

    • Cummins 3239DEF line heater 2 circuit: Voltage high / shorted high

      Same failure as 3237 on the DEF line heater 2 circuit: the same fault condition as 3237, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3237, applied to the DEF line heater 2 circuit
      • Wiring or connector problem local to the DEF line heater 2 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3237, starting at the DEF line heater 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF line heater 2 circuit - voltage high (shorted to a high source)

    • Cummins 3241DEF line heater 2 circuit: Voltage low / shorted low

      Same failure as 3238 on the DEF line heater 2 circuit: the same fault condition as 3238, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 3238, applied to the DEF line heater 2 circuit
      • Wiring or connector problem local to the DEF line heater 2 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3238, starting at the DEF line heater 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DEF line heater 2 circuit - voltage low (shorted to a low source)

    • Cummins 3261DEF line heater 2 circuit: Current low / open circuit

      Same failure as 3258 on the DEF line heater 2 circuit: the same fault condition as 3258, reported for this part.· Open circuit
      Check soon

      Causes

      • Same causes as 3258, applied to the DEF line heater 2 circuit
      • Wiring or connector problem local to the DEF line heater 2 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3258, starting at the DEF line heater 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:DEF line heater 2 circuit - current low or open circuit

  • DEF line heater 3 circuit3 codes

    • Cummins 3422DEF line heater 3 circuit: Voltage high / shorted high

      Same failure as 3237 on the DEF line heater 3 circuit: the same fault condition as 3237, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3237, applied to the DEF line heater 3 circuit
      • Wiring or connector problem local to the DEF line heater 3 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3237, starting at the DEF line heater 3 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF line heater 3 circuit - voltage high (shorted to a high source)

    • Cummins 3423DEF line heater 3 circuit: Voltage low / shorted low

      Same failure as 3238 on the DEF line heater 3 circuit: the same fault condition as 3238, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 3238, applied to the DEF line heater 3 circuit
      • Wiring or connector problem local to the DEF line heater 3 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3238, starting at the DEF line heater 3 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DEF line heater 3 circuit - voltage low (shorted to a low source)

    • Cummins 3425DEF line heater 3 circuit: Current low / open circuit

      Same failure as 3258 on the DEF line heater 3 circuit: the same fault condition as 3258, reported for this part.· Open circuit
      Check soon

      Causes

      • Same causes as 3258, applied to the DEF line heater 3 circuit
      • Wiring or connector problem local to the DEF line heater 3 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3258, starting at the DEF line heater 3 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:DEF line heater 3 circuit - current low or open circuit

  • DEF line heater 4 circuit2 codes

    • Cummins 3426DEF line heater 4 circuit: Voltage high / shorted high

      Same failure as 3237 on the DEF line heater 4 circuit: the same fault condition as 3237, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3237, applied to the DEF line heater 4 circuit
      • Wiring or connector problem local to the DEF line heater 4 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3237, starting at the DEF line heater 4 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF line heater 4 circuit - voltage high (shorted to a high source)

    • Cummins 3429DEF line heater 4 circuit: Current low / open circuit

      Same failure as 3258 on the DEF line heater 4 circuit: the same fault condition as 3258, reported for this part.· Open circuit
      Check soon

      Causes

      • Same causes as 3258, applied to the DEF line heater 4 circuit
      • Wiring or connector problem local to the DEF line heater 4 circuit

      Checks

      1. 1Measure the heater resistance and check its relay and fuse, in cold conditions if possible.
      2. 2Work through the checks listed for 3258, starting at the DEF line heater 4 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:DEF line heater 4 circuit - current low or open circuit

  • DEF temperature sensor1 code

    • Cummins 4233DEF temperature sensor: Voltage high / shorted high

      Same failure as 3237 on the DEF temperature sensor: the same fault condition as 3237, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 3237, applied to the DEF temperature sensor
      • Wiring or connector problem local to the DEF temperature sensor

      Checks

      1. 1Compare the reading with the other DEF temperature sensors at ambient.
      2. 2Work through the checks listed for 3237, starting at the DEF temperature sensor and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF temperature sensor - voltage high (shorted to a high source)

  • DEF temperature sensor circuit1 code

    • Cummins 4234DEF temperature sensor circuit: Voltage low / shorted low

      Same failure as 3238 on the DEF temperature sensor circuit: the same fault condition as 3238, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 3238, applied to the DEF temperature sensor circuit
      • Wiring or connector problem local to the DEF temperature sensor circuit

      Checks

      1. 1Compare the reading with the other DEF temperature sensors at ambient.
      2. 2Work through the checks listed for 3238, starting at the DEF temperature sensor circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DEF temperature sensor circuit - voltage low (shorted to a low source)

  • DEF temperature 22 codes

    • Cummins 4243DEF temperature 2: Abnormal rate of change

      The DEF temperature 2 changed faster than it physically could, so the ECM treats the reading as a sensor or wiring problem and not as a real change.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the harness or connector of the DEF temperature 2
      • Failing part giving unstable output
      • Poor ground or noisy supply feeding the circuit

      Checks

      1. 1Log the DEF temperature 2 while moving the harness and connector, and look for steps instead of smooth changes
      2. 2Inspect the DEF temperature 2 connector for water, corrosion and loose pins
      3. 3Check the supply and ground at the DEF temperature 2 while the engine runs
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4745DEF temperature 2: Root cause not known

      The ECM logged a fault on the DEF temperature 2 but could not narrow down the cause.· Other
      Info

      Causes

      • A related circuit or sensor fault that has not been read yet
      • Intermittent connection that did not repeat during the test
      • Real operating problem that the strategy could not classify

      Checks

      1. 1Read every code on the engine and work the more specific ones first
      2. 2Check the DEF temperature 2 wiring and connectors for damage and corrosion
      3. 3Review the freeze-frame data, if stored, for the operating conditions when the code set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DEF dosing temperature2 codes

    • Cummins 4244DEF dosing temperature: Erratic reading

      The ECM judges the DEF dosing temperature to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact on the DEF dosing temperature
      • Part ageing or failing and giving unstable output
      • Electrical noise from a poorly routed wire or a bad ground

      Checks

      1. 1Watch the DEF dosing temperature live in INSITE and wiggle the harness and connector to catch dropouts
      2. 2Compare the DEF dosing temperature with a related reading to decide which one is wrong
      3. 3Check the connector for moisture and corrosion and the ground connection for tightness
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DEF dosing temperature - data erratic or incorrect

    • Cummins 4249DEF dosing temperature: Abnormal rate of change

      Same failure as 4243 on the DEF dosing temperature: the same fault condition as 4243, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 4243, applied to the DEF dosing temperature
      • Wiring or connector problem local to the DEF dosing temperature

      Checks

      1. 1Compare the reading with the other DEF temperature sensors at ambient.
      2. 2Work through the checks listed for 4243, starting at the DEF dosing temperature and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Other codes1 code

    • Cummins 3238DEF line heater circuit shorted low or driver voltage low

      The ECM reads the DEF line heater circuit shorted low or driver voltage low below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the DEF line heater circuit shorted low or driver voltage low rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the DEF line heater circuit shorted low or driver voltage low connector

      Checks

      1. 1Key on, unplug the DEF line heater circuit shorted low or driver voltage low and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the DEF line heater circuit shorted low or driver voltage low signal wire to ground with the ECM unplugged to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Measure the heater resistance at the connector
  2. 2Check the sensor wiring and connector for damage
  3. 3Compare the reading with ambient temperature on a cold engine
  4. 4Check the heater relay and fuse feeding the heaters
  5. 5Inspect the heated line for chafing and damage
  6. 6Verify the sensor resistance at ambient temperature

Causes

  • Heater element open or shorted
  • Sensor wiring or connector fault
  • Wiring or connector fault
  • Sensor failed

Most common here: shorted high (5 of 17)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: In cold weather the DEF lines may freeze and stop dosing, which leads to an emissions lamp and eventually inducement.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.