Thermo King Fault Code 82

High compressor temperature shutdown

What does Thermo King code 82 mean?

The compressor discharge temperature reached the shutdown limit and the controller stopped the unit to prevent damage to the compressor. Urgency: stop now - shut down and fix before working on. Check first: check for refrigerant leaks and recover or recharge as needed.

FaultStop82Thermo King · Refrigeration system (SR-2/SR-3/SR-4)

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Check for refrigerant leaks and recover or recharge as needed

Then 3 more checks
Code shows hereFAULT82

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

Checks

0 of 4 done

Causes

  • Low charge or loss of refrigerant cooling the compressor
  • Condenser airflow blocked
  • Compressor internal failure
  • Liquid injection or economizer valve not working

How it failed

You'll notice: Alarm 82 and the unit shuts down; it may restart after cooling and shut down again if the cause is still there.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Evaporator, air and compressor temperature sensors

Source

Thermo King Alarm Codes - North America (thermoking.com alarm code list)

This source lists 82 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.