Komatsu · Engine controller
Komatsu Injector and IMV solenoid circuits fault codes
Each injector is fired by a solenoid driven by the engine controller, with one wire pair per cylinder. The IMV (inlet metering valve) on the supply pump controls how much fuel enters the high pressure pump.
More about these partsLess
These codes cover broken or shorted wiring and coil problems on those circuits.
Where this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
What do these codes mean?
Komatsu codes CA271 to CA2311 are all about the injector and IMV solenoid circuits. Most are lost message faults; none needs an immediate stop. Start with this check: check the injector connector under the valve cover for oil, corrosion and loose pins.
How urgent are they?
None of the 11 codes here means stop now; all 11 can wait until the shift ends, but find the cause before the next one.
- Check soon11
What should I check first?
Check the injector connector under the valve cover for oil, corrosion and loose pins
Shared checks11 of 11
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Komatsu CA271IMV/PCV1 short circuit
The engine controller finds the IMV/PCV1 valve circuit shorted. It cannot meter fuel into the high pressure pump properly, so rail pressure control is lost.· Short circuitShort circuitCheck soonCauses
- IMV wire rubbed through at the pump
- Shorted coil inside the IMV
- Water in the IMV connector
Checks
- 1Measure each IMV wire to ground with the connector off
- 2Measure the IMV coil resistance and compare it with the shop manual value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu CA272IMV/PCV1 open circuit
The engine controller finds the IMV/PCV1 valve circuit open. Fuel metering to the high pressure pump cannot be controlled, so rail pressure may go uncontrolled.· Open circuitOpen circuitCheck soonCauses
- Broken IMV wire or loose pin at the pump connector
- Open coil inside the IMV
- Corroded IMV connector
Checks
- 1Check the IMV connector at the pump for pushed-back pins
- 2Measure the IMV coil resistance; an open reading condemns the IMV
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu CA322Injector #1 (L#1) open or short circuit
The engine controller finds an open or shorted circuit on injector #1 (L#1). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #1 under the valve cover loose or corroded
- Wire to injector #1 rubbed through at the cylinder head
- Open or shorted coil in injector #1
- Engine controller driver for cylinder 1 failed
Checks
- 1Measure the coil resistance of injector #1 at its connector and compare it with the other five
- 2Check the harness wires for injector #1 to ground and to each other with the controller unplugged
- 3Inspect the injector connector under the valve cover for oil and corrosion
- 4Check that the injector terminal nut under the valve cover is tight
- 5Cancel cylinder 1 in service mode and see whether engine noise changes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA323Injector #5 (L#5) open or short circuit
The engine controller finds an open or shorted circuit on injector #5 (L#5). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #5 (L#5) loose or corroded
- Wire to injector #5 (L#5) damaged at the head
- Open or shorted injector #5 (L#5) coil
Checks
- 1Measure the coil resistance of injector #5 (L#5) at its connector and compare it with the other injectors
- 2Check the harness wires for injector #5 (L#5) to ground and to each other
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA324Injector #3 (L#3) open or short circuit
The engine controller finds an open or shorted circuit on injector #3 (L#3). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #3 (L#3) loose or corroded
- Wire to injector #3 (L#3) damaged at the head
- Open or shorted injector #3 (L#3) coil
Checks
- 1Measure the coil resistance of injector #3 (L#3) at its connector and compare it with the other injectors
- 2Check the harness wires for injector #3 (L#3) to ground and to each other
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA325Injector #6 (L#6) open or short circuit
The engine controller finds an open or shorted circuit on injector #6 (L#6). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #6 (L#6) loose or corroded
- Wire to injector #6 (L#6) damaged at the head
- Open or shorted injector #6 (L#6) coil
Checks
- 1Measure the coil resistance of injector #6 (L#6) at its connector and compare it with the other injectors
- 2Check the harness wires for injector #6 (L#6) to ground and to each other
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA331Injector #2 (L#2) open or short circuit
The engine controller finds an open or shorted circuit on injector #2 (L#2). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #2 (L#2) loose or corroded
- Wire to injector #2 (L#2) damaged at the head
- Open or shorted injector #2 (L#2) coil
Checks
- 1Measure the coil resistance of injector #2 (L#2) at its connector and compare it with the other injectors
- 2Check the harness wires for injector #2 (L#2) to ground and to each other
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA332Injector #4 (L#4) open or short circuit
The engine controller finds an open or shorted circuit on injector #4 (L#4). That cylinder can misfire or stop injecting, so the engine runs rough and loses power.· Lost messageLost messageCheck soonCauses
- Connector at injector #4 (L#4) loose or corroded
- Wire to injector #4 (L#4) damaged at the head
- Open or shorted injector #4 (L#4) coil
Checks
- 1Measure the coil resistance of injector #4 (L#4) at its connector and compare it with the other injectors
- 2Check the harness wires for injector #4 (L#4) to ground and to each other
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu CA342Calibration code not compatible
The injector or pump calibration code stored in the engine controller does not match the part fitted. The controller will not run the correct fuel map.· Part or controllerPart or controllerCheck soonCauses
- Engine controller replaced without writing the calibration codes
- Injectors or pump replaced and codes not entered
- Wrong controller for the engine
Checks
- 1Compare the calibration code on the injectors and pump with the code in the controller
- 2Write the correct calibration code with the dealer service tool
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Komatsu CA351Injector drive circuit error
The controller reports a fault in the injector drive circuit as a whole, not one cylinder. The injector supply voltage or the drive stage inside the controller is affected.· OtherOtherCheck soonCauses
- Injector supply wire or relay fault
- Water in the main injector harness connector
- Engine controller injector driver failed
Checks
- 1Check the injector supply voltage at the controller connector with key on
- 2Inspect the main engine harness connector for water
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu CA2311IMV solenoid current error
The current through the IMV solenoid does not match what the controller commanded. The pump metering is not following demand, so rail pressure may drift.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Resistance in the IMV connector or wiring
- Weak battery supply to the engine controller
- IMV coil failing
Checks
- 1Check IMV connector terminals for corrosion and heat marks
- 2Check battery voltage at the engine controller with the engine running
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Shared checks
Checks, in order
- 1Check the injector connector under the valve cover for oil, corrosion and loose pins
- 2Measure the injector coil resistance at the harness side and compare it with the shop manual value
- 3Inspect the harness at the cylinder head and bulkhead for rubbed insulation
- 4Cancel the cylinder in service mode and check the engine note change
- 5Swap suspect injectors only after the wiring has been proven
Causes
- Injector connector under the valve cover loose, oily or corroded
- Wire to the injector rubbed through at the cylinder head
- Open or shorted injector coil
- Engine controller driver fault
Most codes here: lost message (6 of 11)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Engine misfires, runs rough or on fewer cylinders, loses power or will not start, with the engine warning on the monitor (user codes E10 or E11 in the SINOCMP table).
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.