EF Logo

Komatsu · Engine controller

Komatsu Engine sensor 5 V supplies fault codes

The engine controller feeds a regulated 5 V supply to its sensors. Supply 1 and supply 2 each power a group of sensors, and the throttle sensor has its own feed.

More about these parts

If a supply is pulled down or up, every sensor on it reads wrongly.

FaultCheckDA25KPKomatsu · Engine sensor 5 V supplies
Code shows hereFAULTDA25KP

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes DA25KP to CA386 are all about the engine sensor 5 V supplies. The most common failure type is shorted high (2 of 5); none needs an immediate stop. Start with this check: check which sensors have codes at the same time; they share the failed supply.

How urgent are they?

None of the 5 codes here means stop now; all 5 can wait until the shift ends, but find the cause before the next one.

  • Check soon5

What should I check first?

Check which sensors have codes at the same time; they share the failed supply

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu DA25KP5 V sensor 1 power supply abnormal

    The pump controller saw its own 5 V sensor supply go out of range.· Other
    Check soon

    Causes

    • Short in a pump or PPC pressure sensor pulling the supply down
    • Chafed wire in the pump controller sensor harness
    • Fault in the pump controller supply output

    Checks

    1. 1Unplug the hydraulic pressure sensors one at a time and watch whether the 5 V supply recovers
    2. 2Measure the supply at the pump controller connector with key on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu CA187Sensor power supply 2: low voltage

    The engine controller sees the sensor power supply 2 signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the sensor power supply 2 shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the sensor power supply 2 connector
    • A shorted sensor that is powered from supply 2 pulling it down

    Checks

    1. 1Unplug the sensor power supply 2 connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Unplug the sensors on supply 2 one at a time and watch whether the supply returns to about 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA227Sensor power supply 2: high voltage

    The engine controller sees the sensor power supply 2 signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the sensor power supply 2 shorted to a 5 V or battery feed
    • Open ground return at the sensor power supply 2, letting the signal float high
    • Supply 2 wire touching a battery feed or another higher voltage

    Checks

    1. 1Unplug the sensor power supply 2 connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Check the supply 2 wire along the harness for contact with a 12 V or 24 V line
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA352Sensor power supply 1: low voltage

    The engine controller sees the sensor power supply 1 signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the sensor power supply 1 shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the sensor power supply 1 connector
    • A shorted sensor powered from supply 1, such as the rail pressure sensor

    Checks

    1. 1Unplug the sensor power supply 1 connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Unplug the sensors on supply 1 one at a time and watch whether the supply returns to about 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA386Sensor power supply 1: high voltage

    The engine controller sees the sensor power supply 1 signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the sensor power supply 1 shorted to a 5 V or battery feed
    • Open ground return at the sensor power supply 1, letting the signal float high
    • Supply 1 wire touching a battery feed or another higher voltage

    Checks

    1. 1Unplug the sensor power supply 1 connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Check the supply 1 wire along the harness for contact with a 12 V or 24 V line
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

Shared checks

Checks, in order

  1. 1Check which sensors have codes at the same time; they share the failed supply
  2. 2Unplug the sensors on the supply one by one and watch the supply voltage recover on the harness side
  3. 3Measure the supply at the controller connector against the standard 5 V
  4. 4Inspect harness and connectors for rubbed insulation and water
  5. 5If the supply stays bad with every sensor unplugged, suspect the engine controller

Causes

  • Short in one sensor on the shared supply pulling the whole line down
  • Chafed harness near the engine or rail pressure sensor
  • Water or corrosion in a sensor connector sharing the supply
  • Faulty engine controller sensor supply output

Most common here: shorted high (2 of 5)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: Several sensor codes appear at once, the engine derates or runs on defaults, and the monitor shows the engine warning with E15 or E14.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.