Komatsu · Engine controller
Komatsu Battery, charging and air heater fault codes
These codes cover the charging system voltage seen by the controllers and the air intake heater relay that helps cold starting. A low charging voltage points to the alternator or its wiring, a high voltage to a regulator fault.
Where this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
What do these codes mean?
Komatsu codes AB00KE to CA2556 are all about the battery, charging and air heater. The most common failure type is shorted high (2 of 5); none needs an immediate stop. Start with this check: measure battery voltage at rest and with the engine running.
How urgent are they?
None of the 5 codes here means stop now; all 5 can wait until the shift ends, but find the cause before the next one.
- Check soon5
What should I check first?
Measure battery voltage at rest and with the engine running
Shared checksStop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Komatsu AB00KECharging voltage low
The charging system voltage is too low. The battery is discharging, and over time the machine will not start or the controllers may reset.· Shorted lowShorted lowCheck soonCauses
- Alternator not charging
- Slipping drive belt
- Loose or corroded battery or alternator cable
- Battery worn out
Checks
- 1Measure the voltage at the battery with the engine running; it should rise above the resting reading
- 2Check the alternator belt tension and the alternator output wire
- 3Check battery terminals and ground cables for corrosion
- 4Check the alternator output with the engine running at fast idle
- 5Check the fuse or fusible link on the charge circuit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Komatsu CA441Battery voltage low
The engine controller sees battery voltage below its working range. It can cause resets, hard starting or sensor codes.· Shorted lowShorted lowCheck soonCauses
- Discharged or old battery
- Corroded battery terminals
- Alternator not charging
- High resistance in the controller supply wire
Checks
- 1Measure battery voltage with the engine off and while cranking
- 2Clean the battery terminals and the frame ground connections
- 3Check the charging voltage with the engine running
- 4Check the voltage at the engine controller supply pin with the engine running
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Komatsu CA442Battery voltage high
The engine controller sees battery voltage above its working range. A faulty alternator regulator can overcharge the system and damage electronics.· Shorted highShorted highCheck soonCauses
- Alternator regulator failed
- Wrong battery type or voltage
- Loose sense wire at the alternator
Checks
- 1Measure charging voltage with the engine running
- 2Check the alternator regulator and sense connection
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Komatsu CA2555Air heater relay: high voltage
The air heater (intake grid heater) relay circuit shows a voltage above its range. Cold starting aid may not work and the controller cannot control the heater.· Shorted highShorted highCheck soonCauses
- Heater relay output stuck on or shorted to feed
- Wire touching a battery feed
Checks
- 1Check the heater relay for a stuck contact
- 2Check the heater relay control wire for contact with a power line
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Komatsu CA2556Air heater relay: voltage error
The air heater relay circuit shows a wrong voltage when the controller expects it to be on or off. The heater may not warm the intake.· OtherOtherCheck soonCauses
- Heater relay coil open
- Blown heater fuse or fusible link
- Relay output wire open
Checks
- 1Check the heater fuse and fusible link
- 2Check the relay output with the heater commanded on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Measure battery voltage at rest and with the engine running
- 2Check terminals and ground straps for corrosion and heat marks
- 3Check the alternator drive belt tension and condition
- 4Check the relay and the fuse in the air heater circuit
- 5Inspect the heater wiring for burnt connectors
Causes
- Loose or corroded battery terminals or ground straps
- Alternator drive belt slipping or alternator failed
- Heater relay or its wiring failed
- Fuse blown in the charge or heater circuit
Most common here: shorted high (2 of 5)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: Battery warning on the monitor, hard cold starting or no heater-plug action.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Komatsu Error Code List (PC200-6/PC300-6/PC400-6/PC200-7 user and service codes, PC200-8 failure code index)
- Komatsu Fault Codes List (SlideShare, PC200-8 user and failure codes)
- SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?