EF Logo

Komatsu · Engine controller

Komatsu Battery, charging and air heater fault codes

These codes cover the charging system voltage seen by the controllers and the air intake heater relay that helps cold starting. A low charging voltage points to the alternator or its wiring, a high voltage to a regulator fault.

FaultCheckAB00KEKomatsu · Battery, charging and air heater
Code shows hereFAULTAB00KE

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes AB00KE to CA2556 are all about the battery, charging and air heater. The most common failure type is shorted high (2 of 5); none needs an immediate stop. Start with this check: measure battery voltage at rest and with the engine running.

How urgent are they?

None of the 5 codes here means stop now; all 5 can wait until the shift ends, but find the cause before the next one.

  • Check soon5

What should I check first?

Measure battery voltage at rest and with the engine running

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu AB00KECharging voltage low

    The charging system voltage is too low.· Shorted low
    Check soon

    Causes

    • Alternator not charging
    • Slipping drive belt
    • Loose or corroded battery or alternator cable
    • Battery worn out

    Checks

    1. 1Measure the voltage at the battery with the engine running; it should rise above the resting reading
    2. 2Check the alternator belt tension and the alternator output wire
    3. 3Check battery terminals and ground cables for corrosion
    4. 4Check the alternator output with the engine running at fast idle
    5. 5Check the fuse or fusible link on the charge circuit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA441Battery voltage low

    The engine controller sees battery voltage below its working range.· Shorted low
    Check soon

    Causes

    • Discharged or old battery
    • Corroded battery terminals
    • Alternator not charging
    • High resistance in the controller supply wire

    Checks

    1. 1Measure battery voltage with the engine off and while cranking
    2. 2Clean the battery terminals and the frame ground connections
    3. 3Check the charging voltage with the engine running
    4. 4Check the voltage at the engine controller supply pin with the engine running
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA442Battery voltage high

    The engine controller sees battery voltage above its working range.· Shorted high
    Check soon

    Causes

    • Alternator regulator failed
    • Wrong battery type or voltage
    • Loose sense wire at the alternator

    Checks

    1. 1Measure charging voltage with the engine running
    2. 2Check the alternator regulator and sense connection
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA2555Air heater relay: high voltage

    The air heater (intake grid heater) relay circuit shows a voltage above its range.· Shorted high
    Check soon

    Causes

    • Heater relay output stuck on or shorted to feed
    • Wire touching a battery feed

    Checks

    1. 1Check the heater relay for a stuck contact
    2. 2Check the heater relay control wire for contact with a power line
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA2556Air heater relay: voltage error

    The air heater relay circuit shows a wrong voltage when the controller expects it to be on or off.· Other
    Check soon

    Causes

    • Heater relay coil open
    • Blown heater fuse or fusible link
    • Relay output wire open

    Checks

    1. 1Check the heater fuse and fusible link
    2. 2Check the relay output with the heater commanded on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Measure battery voltage at rest and with the engine running
  2. 2Check terminals and ground straps for corrosion and heat marks
  3. 3Check the alternator drive belt tension and condition
  4. 4Check the relay and the fuse in the air heater circuit
  5. 5Inspect the heater wiring for burnt connectors

Causes

  • Loose or corroded battery terminals or ground straps
  • Alternator drive belt slipping or alternator failed
  • Heater relay or its wiring failed
  • Fuse blown in the charge or heater circuit

Most common here: shorted high (2 of 5)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: Battery warning on the monitor, hard cold starting or no heater-plug action.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.