Komatsu · Engine controller
Komatsu Fault Code CA441
Battery voltage low
What does Komatsu code CA441 mean?
The engine controller sees battery voltage below its working range. It can cause resets, hard starting or sensor codes. Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage with the engine off and while cranking.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure battery voltage with the engine off and while cranking
Then 3 more checksWhere this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
Checks
0 of 4 done
Causes
- Discharged or old battery
- Corroded battery terminals
- Alternator not charging
- High resistance in the controller supply wire
How it failed
You'll notice: Engine controller reports low battery voltage with CA441.
Shorted lowRead from how the source describes the code
The signal sits at or near zero volts - less than a working sensor can send.
- Meter test
- Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
- Good result
- Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Battery, charging and air heater
1 other code on this part is also shorted low (AB00KE). When they show together, start at the wiring and connector they share.
- AB00KECharging voltage lowShorted lowCheck soon
- CA441Battery voltage lowShorted lowCheck soon
- CA442Battery voltage highShorted highCheck soon
- CA2555Air heater relay: high voltageShorted highCheck soon
- CA2556Air heater relay: voltage errorOtherCheck soon
Other Komatsu codes: Engine controller
Related on Equipments Finder
Source
SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
This source lists CA441 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.