Komatsu · Engine controller
Komatsu Fault Code CA449
Common rail pressure too high (stage 2)
What does Komatsu code CA449 mean?
The measured rail pressure went above the upper limit. The controller shuts down or limits the engine to stop the fuel system from being overloaded. Urgency: stop now - shut down and fix before working on. Check first: read rail pressure in service mode and compare it with the commanded value.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Read rail pressure in service mode and compare it with the commanded value
Then 3 more checksWhere this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
Checks
0 of 4 done
Causes
- IMV valve stuck closed so the supply pump over-delivers
- Pressure limiter valve stuck
- Rail pressure sensor reading lower than the real pressure
- Damaged IMV connector or harness
How it failed
You'll notice: Engine runs rough or stops with CA449 on the monitor.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Common rail fuel pressure
1 other code on this part is also shorted high (CA451). When they show together, start at the wiring and connector they share.
- CA449Common rail pressure too high (stage 2)Shorted highStop now
- CA451Common rail pressure sensor: high voltageShorted highCheck soon
- CA452Common rail pressure sensor: low voltageShorted lowCheck soon
- CA553Common rail pressure too high (stage 1)Real conditionCheck soon
- CA559Common rail pressure too low (stage 1)Real conditionCheck soon
- CA2249Common rail pressure too low (stage 2)Real conditionStop now
Other Komatsu codes: Engine controller
Related on Equipments Finder
Source
SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
This source lists CA449 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.