EF Logo

Komatsu · Pump controller

Komatsu Pump, PPC, load and oil temperature sensors fault codes

The pump controller reads the front and rear pump pressures, the pilot (PPC) pressure of each joystick direction, the work load and the hydraulic oil temperature. It uses them to set pump output and to decide which function the operator is asking for.

FaultCheckDHPAMAKomatsu · Pump, PPC, load and oil temperature sensors
Code shows hereFAULTDHPAMA

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes DHPAMA to DHS8MA are all about the pump, PPC, load and oil temperature sensors. The most common failure type is lost message (2 of 10); none needs an immediate stop. Start with this check: check the 5 V sensor supply code first, DA25KP, before blaming a single sensor.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Check the 5 V sensor supply code first, DA25KP, before blaming a single sensor

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu DHPAMAFront pump pressure sensor abnormal

    The front pump pressure sensor signal is outside range or not following the real pump pressure.· Lost message
    Check soon

    Causes

    • Front pump pressure sensor connector loose, oily or corroded
    • Sensor wire open or shorted
    • Failed front pump pressure sensor
    • Blocked sensor port
    • 5 V sensor supply low

    Checks

    1. 1Check the sensor supply and the DA25KP code first
    2. 2Unplug the front pump pressure sensor and measure the supply, ground and signal wires with key on
    3. 3Compare the front and rear pump pressure readings in service mode at idle and under load
    4. 4Inspect the harness between the sensor and the pump controller for chafing
    5. 5Swap the front and rear pump pressure sensors and see whether the fault follows the sensor
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu DHPBMARear pump pressure sensor: abnormal

    The pump controller finds the rear pump pressure sensor signal abnormal, either out of range or not following the machine's state.· Lost message
    Check soon

    Causes

    • Rear pump pressure sensor connector wet or loose
    • Failed rear pump pressure sensor
    • Rear pump sensor port blocked

    Checks

    1. 1Unplug the rear pump pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the rear pump pressure sensor reading in service mode with its opposite number on the machine
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu DHSAMASwing right PPC pressure sensor: abnormal

    The pump controller finds the swing right PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Swing right PPC pressure sensor connector wet or loose
    • Failed swing right PPC pressure sensor
    • Swing right PPC pilot line leaking

    Checks

    1. 1Unplug the swing right PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the swing right PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DHSBMASwing left PPC pressure sensor: abnormal

    The pump controller finds the swing left PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Swing left PPC pressure sensor connector wet or loose
    • Failed swing left PPC pressure sensor
    • Swing left PPC pilot line leaking

    Checks

    1. 1Unplug the swing left PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the swing left PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DHSDMABucket dump PPC pressure sensor: abnormal

    The pump controller finds the bucket dump PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Bucket dump PPC pressure sensor connector wet or loose
    • Failed bucket dump PPC pressure sensor
    • Bucket dump PPC pilot line leaking

    Checks

    1. 1Unplug the bucket dump PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the bucket dump PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DHX1MAOverload (load) sensor (analog): abnormal

    The pump controller finds the overload (load) sensor (analog) signal abnormal, either out of range or not following the machine's state.· Real condition
    Check soon

    Causes

    • Overload (load) sensor (analog) connector wet or loose
    • Failed overload (load) sensor (analog)
    • Load sensor mounting or calibration fault

    Checks

    1. 1Unplug the overload (load) sensor (analog) and measure the signal and ground wires with key on
    2. 2Compare the overload (load) sensor (analog) reading in service mode with its opposite number on the machine
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Komatsu DGH2KBHydraulic oil temperature sensor short circuit

    The hydraulic oil temperature sensor signal is shorted to ground.· Shorted low
    Check soon

    Causes

    • Oil temperature sensor wire shorted to ground
    • Failed oil temperature sensor
    • Water in the sensor connector

    Checks

    1. 1Unplug the sensor and measure the signal wire to ground; a short means the harness
    2. 2Check the sensor resistance against a warm and a cold oil temperature
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu DHS3MAArm-in (bucket arm retraction) PPC pressure sensor: abnormal

    The pump controller finds the arm-in (bucket arm retraction) PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Arm-in (bucket arm retraction) PPC pressure sensor connector wet or loose
    • Failed arm-in (bucket arm retraction) PPC pressure sensor
    • Arm-in PPC pilot line leaking

    Checks

    1. 1Unplug the arm-in (bucket arm retraction) PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the arm-in (bucket arm retraction) PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DHS4MABucket curl (bucket excavation) PPC pressure sensor: abnormal

    The pump controller finds the bucket curl (bucket excavation) PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Bucket curl (bucket excavation) PPC pressure sensor connector wet or loose
    • Failed bucket curl (bucket excavation) PPC pressure sensor
    • Bucket curl PPC pilot line leaking

    Checks

    1. 1Unplug the bucket curl (bucket excavation) PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the bucket curl (bucket excavation) PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DHS8MABoom raise PPC pressure sensor: abnormal

    The pump controller finds the boom raise PPC pressure sensor signal abnormal, either out of range or not following the machine's state.· Other
    Check soon

    Causes

    • Boom raise PPC pressure sensor connector wet or loose
    • Failed boom raise PPC pressure sensor
    • Boom raise PPC pilot line leaking

    Checks

    1. 1Unplug the boom raise PPC pressure sensor and measure the signal and ground wires with key on
    2. 2Compare the boom raise PPC pressure sensor reading in service mode with its opposite number on the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check the 5 V sensor supply code first, DA25KP, before blaming a single sensor
  2. 2Inspect the sensor connector for water, oil and pushed-back pins
  3. 3Compare the sensor reading in service mode with the matching sensor on the other side
  4. 4Check the sensor wires from plug to pump controller for chafing
  5. 5Swap with a sensor of the same type to see if the fault follows the sensor

Causes

  • Pressure sensor connector loose, oily or corroded
  • Sensor wire rubbed through along the boom or in the cab harness
  • Failed sensor or blocked pressure port
  • Pump controller supply to the 5 V sensors low

Most common here: lost message (2 of 10)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: Slow or weak digging, a function that does not respond, or pump output that feels wrong, with the monitor showing the failure code.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.