EF Logo

Komatsu · Pump controller

Komatsu Controller network, option and GPS codes fault codes

These pump controller and monitor codes are about the machine network (CAN) and options: the model selection, the CAN link to the pump controller, the personal code relay and the GPS antenna.

FaultCheckDA2RMCKomatsu · Controller network, option and GPS codes
Code shows hereFAULTDA2RMC

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes DA2RMC to D862KA are all about the controller network, option and GPS codes. The most common failure type is lost message (2 of 4); none needs an immediate stop. Start with this check: check the CAN link wires and connectors between the controllers.

How urgent are they?

None of the 4 codes here means stop now; 3 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon3
  • Info1

What should I check first?

Check the CAN link wires and connectors between the controllers

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu DA2RMCCAN circuit break (pump controller connection)

    The monitor or engine controller no longer detects the pump controller on the CAN link.· Lost message
    Check soon

    Causes

    • CAN wire open or shorted between the controllers
    • Pump controller without power or ground
    • Connector loose at the pump controller

    Checks

    1. 1Check pump controller supply and ground first
    2. 2Measure the resistance across the CAN pair at the controller connector to check termination
    3. 3Inspect the pump controller connector for loose or pushed-back pins
    4. 4Check the monitor for the same code to see which controller is missing
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu D19JKZPersonal code relay abnormal

    The personal (anti-theft) code relay does not match its commanded state.· Other
    Check soon

    Causes

    • Relay failed or wiring open
    • Personal code system wiring fault

    Checks

    1. 1Check the relay and its wiring
    2. 2Test the relay in service mode if available
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DA29KQModel selection abnormal

    The model selection data in the controller does not match the machine.· Lost message
    Check soon

    Causes

    • Controller replaced without the model being set
    • Model selection wires open or shorted

    Checks

    1. 1Compare the model selection set in the controller with the machine model
    2. 2Set the model with the service tool after a controller change
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu D862KAGPS antenna circuit break

    The GPS antenna circuit is open.· Open circuit
    Info

    Causes

    • Antenna cable broken or unplugged
    • Failed GPS antenna

    Checks

    1. 1Check the antenna cable and connector
    2. 2Replace the antenna if the cable is good
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

Shared checks

Checks, in order

  1. 1Check the CAN link wires and connectors between the controllers
  2. 2Check power and ground at each controller
  3. 3Confirm the model and option settings match the machine
  4. 4Inspect the antenna and relay wiring where fitted

Causes

  • Open or shorted CAN wires in the cab or main harness
  • Loose controller connector
  • Controller replaced without setting the model or options
  • Antenna or relay wiring damaged

Most common here: lost message (2 of 4)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: The monitor loses data from the pump controller, some functions drop out, or a model or option feature does not work, with the failure code on the monitor (user code E0E for network faults).

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.