Komatsu · Pump controller
Komatsu Wiper and washer circuits fault codes
The pump controller drives the windshield wiper and washer motors and monitors them. A circuit break (KA) means no current flows; a short (KB) means the output is overloaded.
More about these partsLess
These faults do not stop the machine but leave the operator without wiper or washer.
Where this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
What do these codes mean?
Komatsu codes DY2CKA to DY20MA are all about the wiper and washer circuits. None needs an immediate stop. Start with this check: check the wiper and washer fuse in the cab fuse box.
How urgent are they?
None of the 4 codes here means stop now; 4 are information only.
- Info4
What should I check first?
Check the wiper and washer fuse in the cab fuse box
Shared checksStop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Komatsu DY2CKAWasher drive circuit break
The washer pump circuit is open, so the washer will not spray.· Open circuitOpen circuitInfoCauses
- Washer pump open or failed
- Open washer wire
Checks
- 1Check the washer fluid level and pump connector
- 2Measure the washer pump resistance
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DY2CKBWasher drive short circuit
The washer pump circuit is shorted. The output cuts off to protect itself and the washer will not work.· Short circuitShort circuitInfoCauses
- Washer pump shorted
- Washer wire touching ground
Checks
- 1Unplug the washer pump and see whether the code clears
- 2Check the washer wire for rubbed insulation
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu DY20KAWindshield wiper malfunction
The wiper motor circuit is faulty, so the wiper may not run or park properly.· OtherOtherInfoCauses
- Wiper motor worn out
- Wiring or connector fault
Checks
- 1Check the wiper motor connector and wires
- 2Check whether the motor runs when powered directly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DY20MAWiper parking abnormal
The wiper does not park in the expected position, so it can stop in the middle of the screen.· Lost messageLost messageInfoCauses
- Wiper park switch inside the motor worn
- Park wire open
Checks
- 1Run the wiper and watch where it stops
- 2Check the park wiring at the motor connector
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Check the wiper and washer fuse in the cab fuse box
- 2Check the motor connector at the cab roof for water
- 3Run the wiper in all modes and see whether it parks
- 4Check for an obstructed wiper arm or a bent linkage
Causes
- Wiper or washer motor failed
- Wiring or connector fault at the cab roof
- Fuse blown
- Worn wiper arm binding the motor
When to stop
You'll notice: The windshield wiper or washer does not work, with the failure code on the monitor.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
- Komatsu Fault Codes List (SlideShare, PC200-8 user and failure codes)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.