Komatsu · Pump controller
Komatsu Pump PC-EPC, LS-EPC and flow divider solenoids fault codes
The pump controller drives electric proportional solenoids (EPC valves) that set the output of the front and rear pumps (PC-EPC), the load sensing pressure (LS-EPC), a backup current circuit and the flow divider valves. They are current-driven coils on the pump or the main valve.
Where this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
What do these codes mean?
Komatsu codes DXE0KA to DA22KK are all about the pump PC-EPC, LS-EPC and flow divider solenoids. The most common failure type is open circuit (6 of 13); none needs an immediate stop. Start with this check: inspect the solenoid connector at the pump or valve for water and corrosion.
How urgent are they?
None of the 13 codes here means stop now; all 13 can wait until the shift ends, but find the cause before the next one.
- Check soon13
What should I check first?
Inspect the solenoid connector at the pump or valve for water and corrosion
Shared checks13 of 13
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Komatsu DXE0KALS-EPC solenoid: circuit open
The pump controller finds the LS-EPC solenoid circuit open, so no current can flow through the coil. The function it drives will not work or will stay in its rest position. Load sensing pressure control is lost. Expect jerky or slow movements when several functions are used together, because the pumps no longer follow the load signal smoothly.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin between the pump controller and the LS-EPC solenoid
- Open coil inside the LS-EPC solenoid
- LS-EPC valve contaminated by dirty hydraulic oil
Checks
- 1Key off, unplug the LS-EPC solenoid and measure the coil resistance; an open reading condemns the coil
- 2Check the LS-EPC connector and compare its coil resistance with the PC-EPC coils
- 3Find the LS-EPC valve on the pump or main valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXE0KBLS-EPC solenoid: circuit short
The pump controller finds the LS-EPC solenoid circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. Load sensing pressure control is lost. Expect jerky or slow movements when several functions are used together, because the pumps no longer follow the load signal smoothly.· OtherOtherCheck soonCauses
- Harness wire to the LS-EPC solenoid rubbed through and touching ground or another feed
- Shorted turns or water inside the LS-EPC solenoid coil
- LS-EPC valve contaminated by dirty hydraulic oil
Checks
- 1Unplug the LS-EPC solenoid and measure each wire to ground; any continuity means the harness is shorted
- 2Check the LS-EPC connector and compare its coil resistance with the PC-EPC coils
- 3Find the LS-EPC valve on the pump or main valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DXE4KABackup current EPC: circuit open
The pump controller finds the backup current EPC circuit open, so no current can flow through the coil. The function it drives will not work or will stay in its rest position. The backup current circuit that keeps the pump working if the controller fails is not usable. Normal work may feel fine because this circuit is only a backup, but the fail-safe path would not work if the controller failed.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin between the pump controller and the backup current EPC
- Open coil inside the backup current EPC
- Backup current switch wiring open
Checks
- 1Key off, unplug the backup current EPC and measure the coil resistance; an open reading condemns the coil
- 2Check the backup switch position and the backup wiring to the pump
- 3Trace the backup current wiring from the backup switch to the pump controller and check each joint.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXE4KBBackup current EPC: circuit short
The pump controller finds the backup current EPC circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. The backup current circuit that keeps the pump working if the controller fails is not usable. Normal work may feel fine because this circuit is only a backup, but the fail-safe path would not work if the controller failed.· OtherOtherCheck soonCauses
- Harness wire to the backup current EPC rubbed through and touching ground or another feed
- Shorted turns or water inside the backup current EPC coil
- Backup current switch wiring open
Checks
- 1Unplug the backup current EPC and measure each wire to ground; any continuity means the harness is shorted
- 2Check the backup switch position and the backup wiring to the pump
- 3Trace the backup current wiring from the backup switch to the pump controller and check each joint.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DXE5KAFlow divider main solenoid: circuit open
The pump controller finds the flow divider main solenoid circuit open, so no current can flow through the coil. The function it drives will not work or will stay in its rest position. The main flow divider valve cannot be commanded. Expect combined movements such as boom raise with swing to react differently, as the main flow divider is not following the command.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin between the pump controller and the flow divider main solenoid
- Open coil inside the flow divider main solenoid
- Flow divider valve spool stuck
Checks
- 1Key off, unplug the flow divider main solenoid and measure the coil resistance; an open reading condemns the coil
- 2Check the flow divider main solenoid connector on the main control valve
- 3Find the flow divider main solenoid on the main control valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXE5KBFlow divider main solenoid: circuit short
The pump controller finds the flow divider main solenoid circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. The main flow divider valve cannot be commanded. Expect combined movements such as boom raise with swing to react differently, as the main flow divider is not following the command.· OtherOtherCheck soonCauses
- Harness wire to the flow divider main solenoid rubbed through and touching ground or another feed
- Shorted turns or water inside the flow divider main solenoid coil
- Flow divider valve spool stuck
Checks
- 1Unplug the flow divider main solenoid and measure each wire to ground; any continuity means the harness is shorted
- 2Check the flow divider main solenoid connector on the main control valve
- 3Find the flow divider main solenoid on the main control valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DXE6KAFlow divider LS solenoid: circuit open
The pump controller finds the flow divider LS solenoid circuit open, so no current can flow through the coil. The function it drives will not work or will stay in its rest position. The LS flow divider valve cannot be commanded. Expect swing and arm movements to lose their smooth blending, as the load sensing part of the flow divider cannot be commanded.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin between the pump controller and the flow divider LS solenoid
- Open coil inside the flow divider LS solenoid
- LS flow divider valve spool stuck
Checks
- 1Key off, unplug the flow divider LS solenoid and measure the coil resistance; an open reading condemns the coil
- 2Check the flow divider LS solenoid connector on the main control valve
- 3Find the flow divider LS solenoid on the main control valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXE6KBFlow divider LS solenoid: circuit short
The pump controller finds the flow divider LS solenoid circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. The LS flow divider valve cannot be commanded. Expect swing and arm movements to lose their smooth blending, as the load sensing part of the flow divider cannot be commanded.· OtherOtherCheck soonCauses
- Harness wire to the flow divider LS solenoid rubbed through and touching ground or another feed
- Shorted turns or water inside the flow divider LS solenoid coil
- LS flow divider valve spool stuck
Checks
- 1Unplug the flow divider LS solenoid and measure each wire to ground; any continuity means the harness is shorted
- 2Check the flow divider LS solenoid connector on the main control valve
- 3Find the flow divider LS solenoid on the main control valve and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DXA8KAPC-EPC (front pump) solenoid: circuit open
The pump controller finds the front pump PC-EPC solenoid circuit open, so no current reaches the coil that sets the front pump output. The front pump cannot be adjusted, and the machine loses pump power or responds slowly.· Open circuitOpen circuitCheck soonCauses
- Front PC-EPC connector at the pump loose, oily or corroded
- Open wire between the pump controller and the front PC-EPC solenoid
- Open coil in the front PC-EPC solenoid
- Pump controller output stage failed
Checks
- 1Look at the front PC-EPC connector at the pump for water, corrosion and pushed-back pins
- 2Unplug the solenoid and measure the coil resistance; an open reading condemns the solenoid
- 3Measure continuity of both wires from the solenoid plug to the pump controller connector
- 4Compare with the rear PC-EPC coil resistance, which should be similar
- 5Swap the front and rear connectors temporarily to see whether the code moves with the solenoid
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXA8KBPC-EPC (front pump) solenoid: circuit short
The pump controller finds the PC-EPC (front pump) solenoid circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. The front pump then cannot be set by the controller. Expect the front half of the hydraulics, usually boom and arm, to feel starved when both pumps are asked for flow together.· OtherOtherCheck soonCauses
- Harness wire to the PC-EPC (front pump) solenoid rubbed through and touching ground or another feed
- Shorted turns or water inside the PC-EPC (front pump) solenoid coil
- Front pump EPC solenoid stuck inside the pump regulator
Checks
- 1Unplug the PC-EPC (front pump) solenoid and measure each wire to ground; any continuity means the harness is shorted
- 2Compare the front PC-EPC coil resistance with the rear one
- 3Find the front PC-EPC valve on the front pump regulator and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DXA9KAPC-EPC (rear pump) solenoid: circuit open
The pump controller finds the PC-EPC (rear pump) solenoid circuit open, so no current can flow through the coil. The function it drives will not work or will stay in its rest position. The rear pump then cannot be set by the controller. Expect the rear pump side, often the travel and bucket circuits, to lose speed when the machine is loaded.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin between the pump controller and the PC-EPC (rear pump) solenoid
- Open coil inside the PC-EPC (rear pump) solenoid
- Rear pump EPC solenoid stuck inside the pump regulator
Checks
- 1Key off, unplug the PC-EPC (rear pump) solenoid and measure the coil resistance; an open reading condemns the coil
- 2Compare the rear PC-EPC coil resistance with the front one
- 3Find the rear PC-EPC valve on the rear pump regulator and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu DXA9KBPC-EPC (rear pump) solenoid: circuit short
The pump controller finds the PC-EPC (rear pump) solenoid circuit shorted, so the coil is no longer limiting current. The controller cuts the output to protect itself and the function stays off. The rear pump then cannot be set by the controller. Expect the rear pump side, often the travel and bucket circuits, to lose speed when the machine is loaded.· OtherOtherCheck soonCauses
- Harness wire to the PC-EPC (rear pump) solenoid rubbed through and touching ground or another feed
- Shorted turns or water inside the PC-EPC (rear pump) solenoid coil
- Rear pump EPC solenoid stuck inside the pump regulator
Checks
- 1Unplug the PC-EPC (rear pump) solenoid and measure each wire to ground; any continuity means the harness is shorted
- 2Compare the rear PC-EPC coil resistance with the front one
- 3Find the rear PC-EPC valve on the rear pump regulator and check its plug first.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu DA22KKPump solenoid coil power supply low
The supply that powers the pump controller solenoid outputs is too low. Several solenoid codes can appear at the same time because the supply is shared.· Lost messageLost messageCheck soonCauses
- Weak battery or charging fault
- Loose or corroded pump controller power connector
- Blown solenoid supply fuse or poor ground
Checks
- 1Check the battery voltage and the solenoid supply fuse
- 2Measure the supply at the pump controller connector with the engine running
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Inspect the solenoid connector at the pump or valve for water and corrosion
- 2Measure the solenoid coil resistance and compare it with the shop manual value
- 3Measure the solenoid wires to ground with the controller connector off
- 4Swap the front and rear PC-EPC connectors to see whether the fault follows the solenoid
- 5Check pump controller supply and ground before suspecting the controller
Causes
- Connector at the pump or valve solenoid wet, oily or corroded
- Wire to the solenoid rubbed through at the pump bracket
- Failed solenoid coil, open or shorted
- Pump controller output stage failed
Most common here: open circuit (6 of 13)
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
When to stop
You'll notice: Weak or slow hydraulics, the machine feels like it has lost pump power, or one function does not respond, with the monitor failure code (user code E02 for PC-EPC in the SINOCMP table).
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.