JLG Fault Code 442

Battery voltage too high - system shutdown

What does JLG code 442 mean?

Battery voltage is above about 16 V and the system shuts down to protect the electronics. The EMS has to be recycled to clear it. Urgency: stop now - shut down and fix before working on. Check first: measure the voltage at the battery with the engine running to see if the alternator is overcharging.

FaultStop442JLG · Electrical

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Measure the voltage at the battery with the engine running to see if the alternator is overcharging

Then 4 more checks
Code shows hereFAULT442

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • Alternator regulator failed so it overcharges
  • Wrong battery or charger connected, or a booster left on
  • Loose sense wire at the alternator letting voltage run high
  • Battery disconnect or cable fault causing voltage spikes

How it failed

You'll notice: The system shuts down to protect the electronics because battery voltage went above about 16 V.

Shorted highRead from how the source describes the code

The signal sits at or near the supply voltage - more than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good result
Open circuit (OL) between them. Any low reading is the short.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs

Source

JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)

This source lists 442 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.