JLG · Electrical
JLG Fault Code 442
Battery voltage too high - system shutdown
What does JLG code 442 mean?
Battery voltage is above about 16 V and the system shuts down to protect the electronics. The EMS has to be recycled to clear it. Urgency: stop now - shut down and fix before working on. Check first: measure the voltage at the battery with the engine running to see if the alternator is overcharging.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Measure the voltage at the battery with the engine running to see if the alternator is overcharging
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Alternator regulator failed so it overcharges
- Wrong battery or charger connected, or a booster left on
- Loose sense wire at the alternator letting voltage run high
- Battery disconnect or cable fault causing voltage spikes
How it failed
You'll notice: The system shuts down to protect the electronics because battery voltage went above about 16 V.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs
5 other codes on this part are also shorted high (3311, 3364, 3375, 3378 and more). When they show together, start at the wiring and connector they share.
- 3-1Contactor did not closeOtherCheck soon
- 3-2Contactor did not openOtherCheck soon
- 4-4Battery supply problemOtherCheck soon
- 441Battery voltage too low - system shutdownShorted lowStop now
- 442Battery voltage too high - system shutdownShorted highStop now
- 445Battery voltage low (warning)Shorted lowCheck soon
- 3311Ground Alarm - short to batteryShorted highCheck soon
- 3362Start Solenoid - short to groundShorted lowCheck soon
- 3363Start Solenoid - open circuitOpen circuitCheck soon
Show the other 12 codesHide the other codes
- 3364Start Solenoid - short to batteryShorted highCheck soon
- 3373Generator/welder - short to groundShorted lowCheck soon
- 3374Generator/welder - open circuitOpen circuitCheck soon
- 3375Generator/welder - short to batteryShorted highCheck soon
- 3376Head Tail Light - short to groundShorted lowCheck soon
- 3377Head Tail Light - open circuitOpen circuitCheck soon
- 3378Head Tail Light - short to batteryShorted highCheck soon
- 3379Hour Meter - short to groundShorted lowCheck soon
- 4310No alternator outputOtherCheck soon
- 33279Glowplug - open circuitOpen circuitCheck soon
- 33280Glowplug - short to batteryShorted highCheck soon
- 33281Glowplug - short to groundShorted lowCheck soon
Other JLG codes: Electrical
Related on Equipments Finder
Source
JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
This source lists 442 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.