JLG Fault Code 4‑4
Battery supply problem
What does JLG code 4-4 mean?
Battery voltage is outside the controller's limits. Under 11 V for over 5 s gives a warning only (BATTERY LOW). Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage at rest and while cranking.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure battery voltage at rest and while cranking
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Weak or discharged starting battery
- Loose or corroded battery terminals or main ground
- Alternator undercharging or overcharging (regulator failed)
- Voltage drop in the supply wire to the ground module
How it failed
You'll notice: The platform display or lamp shows a battery voltage problem with a 4-4 flash.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Battery, contactors, starting, generator, lights and alarm outputs
- 3-1Contactor did not closeOtherCheck soon
- 3-2Contactor did not openOtherCheck soon
- 4-4Battery supply problemOtherCheck soon
- 441Battery voltage too low - system shutdownShorted lowStop now
- 442Battery voltage too high - system shutdownShorted highStop now
- 445Battery voltage low (warning)Shorted lowCheck soon
- 3311Ground Alarm - short to batteryShorted highCheck soon
- 3362Start Solenoid - short to groundShorted lowCheck soon
- 3363Start Solenoid - open circuitOpen circuitCheck soon
Show the other 12 codesHide the other codes
- 3364Start Solenoid - short to batteryShorted highCheck soon
- 3373Generator/welder - short to groundShorted lowCheck soon
- 3374Generator/welder - open circuitOpen circuitCheck soon
- 3375Generator/welder - short to batteryShorted highCheck soon
- 3376Head Tail Light - short to groundShorted lowCheck soon
- 3377Head Tail Light - open circuitOpen circuitCheck soon
- 3378Head Tail Light - short to batteryShorted highCheck soon
- 3379Hour Meter - short to groundShorted lowCheck soon
- 4310No alternator outputOtherCheck soon
- 33279Glowplug - open circuitOpen circuitCheck soon
- 33280Glowplug - short to batteryShorted highCheck soon
- 33281Glowplug - short to groundShorted lowCheck soon
Other JLG codes: Electrical
Related on Equipments Finder
Source
JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)
This source lists 4-4 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG boom lifts with the JLG Control System (600S, 600SJ, 660SJ, 600A/AJ, 450A, 510A, 400S, 1200/1350SJP families).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.