Deutz · Exhaust aftertreatment (SCR)
Deutz DEF pump, metering unit and suction unit fault codes
The parts that move and dose DEF: the DEF pump with its reverse valve and pump temperature (SPN 4375), the DEF metering unit and dosing valve (SPN 3361), and the DEF suction unit hardware in the tank. Each code names the part and whether its drive, its feedback or its movement failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 3361 FMI 3 to SPN 524282 FMI 11 are all about the dEF pump, metering unit and suction unit. The most common failure type is shorted low (4 of 22); none needs an immediate stop. Start with this check: listen for the pump at the start of a dosing test and read its status in SerDia.
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Listen for the pump at the start of a dosing test and read its status in SerDia
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
DEF metering unit4 codes
Deutz SPN 3361 FMI 3DEF metering unit: Voltage high / shorted high
The EMR4 sees the output for the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP codes 1077 and 1078, blink code 677.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- DEF metering valve (dosing valve) shorted internally
Checks
- 1Unplug the DEF metering valve (dosing valve): if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - DEF metering unit - Voltage above normal or shorted to high source
Deutz SPN 3361 FMI 4DEF metering unit: Voltage low / shorted low
The EMR4 sees the output for the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1079, blink code 677.· Shorted lowShorted lowCheck soonCauses
- Water in the connector bridging the pins
- DEF metering valve (dosing valve) winding shorted to its housing
- Dosing nozzle blocked by crystallised DEF
Checks
- 1Check the dosing valve for crystal deposits at the nozzle and for a spray pattern during a dosing test
- 2Measure the valve coil resistance and check wiring for heat damage
- 3Unplug the DEF metering valve (dosing valve): if the code changes, the part is the shorted one; if it stays, look at the harness
- 4Measure the winding resistance of the part and look for a very low value
- 5With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - DEF metering unit - Voltage below normal or shorted to low source
Full page for SPN 3361 FMI 4Deutz SPN 3361 FMI 6DEF metering unit: Current high / grounded
The EMR4 sees too much current through the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP code 1075, blink code 677.· Shorted lowShorted lowCheck soonCauses
- Valve needle stuck by crystallised DEF
- Winding partly shorted inside the part
- Dosing nozzle blocked by crystallised DEF
Checks
- 1Check the dosing valve for crystal deposits at the nozzle and for a spray pattern during a dosing test
- 2Measure the DEF metering valve (dosing valve) winding resistance; a low value means it is shorting
- 3Measure the valve coil resistance and check wiring for heat damage
- 4Check the wiring for chafe and for water in the connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - DEF metering unit - Current above normal or grounded circuit
Deutz SPN 3361 FMI 7DEF metering unit: Not responding / out of adjustment
The EMR4 sees the DEF metering valve (dosing valve) (at the exhaust pipe in front of the SCR catalyst, injecting DEF) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 908, blink code 8-8-6.· Part or controllerPart or controllerCheck soonCauses
- Dosing nozzle blocked by crystallised DEF
- Valve coil shorted from heat damage
- Valve needle stuck by crystallised DEF
Checks
- 1Measure the valve coil resistance and check wiring for heat damage
- 2Inspect for soot, oil or foreign matter around the part
- 3Move the part by hand with the key off to see whether it is stuck
- 4Command it from SerDia and watch actual position against commanded
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - DEF metering unit - Mechanical system not responding or out of adjustment
DEF metering valve2 codes
Deutz SPN 4374 FMI 13DEF metering valve: Out of calibration
The EMR4 reports the DEF metering valve (at the exhaust pipe in front of the SCR catalyst, injecting DEF) as out of calibration. The learned end positions or characteristics no longer match what the controller expects. Deutz list: KWP code 894, blink code 8-7-2.· Part or controllerPart or controllerCheck soonCauses
- DEF metering valve replaced without a recalibration
- Mechanical wear or play shifting the end positions
Checks
- 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the DEF metering valve
- 2Check the DEF metering valve for mechanical play or a loose linkage that shifts its end positions
- 3Replace the DEF metering valve if the end-position learn routine in SerDia fails repeatedly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Deutz SPN 524141 FMI 7DEF metering valve: Not responding / out of adjustment
The EMR4 sees the DEF metering valve (at the exhaust pipe in front of the SCR catalyst, injecting DEF) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1827, blink code 192.· Part or controllerPart or controllerCheck soonCauses
- Valve needle stuck by crystallised DEF
- Failed part or a real condition behind the signal
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - DEF metering valve - Mechanical system not responding or out of adjustment
DEF pump3 codes
Deutz SPN 4375 FMI 3DEF pump: Voltage high / shorted high
The EMR4 sees the output for the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1120, blink code 666.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- DEF pump shorted internally
- Connector pin touching a live pin
Checks
- 1Measure the winding or coil resistance of the part
- 2Unplug the DEF pump: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 3Listen for the pump running at key-on and check DEF pressure in SerDia
- 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - DEF pump - Voltage above normal or shorted to high source
Full page for SPN 4375 FMI 3Deutz SPN 4375 FMI 4DEF pump: Voltage low / shorted low
The EMR4 sees the output for the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1121, blink code 666.· Shorted lowShorted lowCheck soonCauses
- Pump motor worn or blocked by crystals
- Output wire chafed to ground or the engine block
- DEF pump winding shorted to its housing
Checks
- 1Inspect the dosing module connector and lines for urea crystals
- 2Unplug the DEF pump: if the code changes, the part is the shorted one; if it stays, look at the harness
- 3Listen for the pump running at key-on and check DEF pressure in SerDia
- 4Measure the winding resistance of the part and look for a very low value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - DEF pump - Voltage below normal or shorted to low source
Deutz SPN 4375 FMI 5DEF pump: Current low / open circuit
The EMR4 sees too little current through the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1118, blink code 666.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Connector left unplugged after earlier work
- DEF pump winding open
Checks
- 1Inspect both ends of the DEF pump circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 2Inspect the dosing module connector and lines for urea crystals
- 3Continuity-test each wire to the matching EMR4 pin
- 4Measure the resistance across the DEF pump terminals: infinity means an open winding
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Exhaust aftertreatment - DEF pump - Current below normal or open circuit
DEF reverse valve4 codes
Deutz SPN 4376 FMI 3DEF reverse valve: Voltage high / shorted high
The EMR4 sees the output for the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1131, blink code 667.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- DEF reverse valve shorted internally
- Valve coil open or shorted
Checks
- 1Check the reverse valve coil resistance against the machine maker spec
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4Look for crystallised urea around the valve and connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - DEF reverse valve - Voltage above normal or shorted to high source
Deutz SPN 4376 FMI 4DEF reverse valve: Voltage low / shorted low
The EMR4 sees the output for the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1132, blink code 667.· Shorted lowShorted lowCheck soonCauses
- DEF reverse valve winding shorted to its housing
- Valve coil open or shorted
- Water in the connector bridging the pins
Checks
- 1Look for crystallised urea around the valve and connector
- 2Unplug the DEF reverse valve: if the code changes, the part is the shorted one; if it stays, look at the harness
- 3Measure the winding resistance of the part and look for a very low value
- 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 5Check the reverse valve coil resistance against the machine maker spec
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - DEF reverse valve - Voltage below normal or shorted to low source
Deutz SPN 4376 FMI 5DEF reverse valve: Current low / open circuit
The EMR4 sees too little current through the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1129, blink code 667.· Open circuitOpen circuitCheck soonCauses
- Connector left unplugged after earlier work
- Broken wire or a pin pushed out of the connector
- Valve coil open or shorted
Checks
- 1Measure the resistance across the DEF reverse valve terminals: infinity means an open winding
- 2Continuity-test each wire to the matching EMR4 pin
- 3Look for crystallised urea around the valve and connector
- 4Check the reverse valve coil resistance against the machine maker spec
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Exhaust aftertreatment - DEF reverse valve - Current below normal or open circuit
Deutz SPN 4376 FMI 12DEF reverse valve: Bad device or component
The EMR4 judges the DEF reverse valve (in the SCR dosing module, reversing flow to purge the lines) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1491, blink code 6-6-7.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the DEF reverse valve
- Water or soot inside the part
- Driver stage in the EMR4 failing
Checks
- 1Read the DEF reverse valve status in SerDia and run any actuator test
- 2Measure supply voltage and ground at the DEF reverse valve connector with the key on to confirm the part is powered
- 3Fit a known good DEF reverse valve if you can borrow one and see whether the code clears for good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - DEF reverse valve - Bad intelligent device or component
Hardware failure temperature sensor DEF suction unit2 codes
Deutz SPN 523668 FMI 11Hardware failure temperature sensor DEF suction unit: Root cause not known
The EMR4 logged a fault on the hardware failure temperature sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause. Treat it as a general failure and test the circuit and the part step by step. Deutz list: KWP code 1464, blink code 1136.· OtherOtherCheck soonCauses
- Intermittent wiring fault that has not stayed long enough to be classified
- Failing part or a real condition the controller flagged
Checks
- 1Read the full SerDia fault list; this code often appears next to a clearer one
- 2Inspect the connector and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Deutz SPN 524282 FMI 11Hardware failure temperature sensor DEF suction unit: Root cause not known
The EMR4 logged a fault on the hardware failure temperature sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause. Treat it as a general failure and test the circuit and the part step by step. Deutz list: KWP code 1468, blink code 1139.· OtherOtherCheck soonCauses
- Intermittent wiring fault that has not stayed long enough to be classified
- Failing part or a real condition the controller flagged
Checks
- 1Read the full SerDia fault list; this code often appears next to a clearer one
- 2Inspect the connector and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Hardware failure quality sensor DEF suction unit1 code
Deutz SPN 523669 FMI 11Hardware failure quality sensor DEF suction unit: Root cause not known
The EMR4 logged a fault on the hardware failure quality sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause. Treat it as a general failure and test the circuit and the part step by step. Deutz list: KWP code 1466, blink code 1137.· OtherOtherCheck soonCauses
- Intermittent wiring fault that has not stayed long enough to be classified
- Failing part or a real condition the controller flagged
Checks
- 1Read the full SerDia fault list; this code often appears next to a clearer one
- 2Inspect the connector and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Hardware failure level sensor DEF suction unit1 code
Deutz SPN 523670 FMI 11Hardware failure level sensor DEF suction unit: Root cause not known
The EMR4 logged a fault on the hardware failure level sensor DEF suction unit (in the DEF tank suction unit) but could not pin down the cause. Treat it as a general failure and test the circuit and the part step by step. Deutz list: KWP code 1467, blink code 1138.· OtherOtherCheck soonCauses
- Intermittent wiring fault that has not stayed long enough to be classified
- Failing part or a real condition the controller flagged
Checks
- 1Read the full SerDia fault list; this code often appears next to a clearer one
- 2Inspect the connector and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Heater DEF metering unit2 codes
Deutz SPN 523720 FMI 2Heater DEF metering unit: Erratic reading
The EMR4 sees the heater DEF metering unit (at the exhaust pipe in front of the SCR catalyst, injecting DEF) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP codes 914 and 915, blink code 1-4-8.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Valve needle stuck by crystallised DEF
- Intermittent contact in the connector
Checks
- 1Command the heater DEF metering unit from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 2Wiggle the heater DEF metering unit harness and connector while watching the live status in SerDia for dropouts
- 3Check both connector halves of the heater DEF metering unit for loose, bent or fretted pins
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Heater DEF metering unit - Data erratic intermittent or incorrect
Deutz SPN 523720 FMI 8Heater DEF metering unit: Abnormal frequency / pulse width
The EMR4 sees an abnormal frequency or pulse width on the heater DEF metering unit (at the exhaust pipe in front of the SCR catalyst, injecting DEF). The signal is present, but its timing is wrong. Deutz list: KWP codes 925 and 926, blink code 148.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Electrical noise or a loose connection distorting the signal
- Sensor or sending unit failing
Checks
- 1Watch the heater DEF metering unit value in SerDia for jumps and dropouts
- 2Inspect the connector and harness for chafe, moisture and loose pins
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Heater DEF metering unit - Abnormal frequency or pulse width or period
DEF pump temperature3 codes
Deutz SPN 524067 FMI 0DEF pump temperature: Reading too high· most severe
The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) above its allowed range. The controller treats this as a serious level. Deutz list: KWP codes 1581 and 1585, blink code 894.· Real conditionReal conditionCheck soonCauses
- Part driven beyond its limit
- Pump seized by crystallised DEF
Checks
- 1Read the actual value against the target in SerDia
- 2Check the DEF pump temperature moves freely through its range by hand with the key off
- 3Inspect the supply and control wiring of the DEF pump temperature for chafe, water and corrosion
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - DEF pump temperature - Data above normal operational range (Most severe level)
Deutz SPN 524067 FMI 1DEF pump temperature: Reading too low· most severe
The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) below its allowed range. The part is not reaching the position or output the controller commands, and it treats the shortfall as serious. Deutz list: KWP codes 1582 and 1586, blink code 894.· Real conditionReal conditionCheck soonCauses
- Part not reaching its commanded value
- Pump seized by crystallised DEF
Checks
- 1Read the actual value against the target in SerDia
- 2Check the part moves through its full travel by hand with the key off
- 3Inspect the supply and control wiring of the DEF pump temperature for chafe, water and corrosion
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - DEF pump temperature - Data below normal operational range (Most severe level)
Deutz SPN 524067 FMI 2DEF pump temperature: Erratic reading
The EMR4 sees the DEF pump temperature (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP codes 1867 and 1868, blink code 894.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Pump seized by crystallised DEF
- Intermittent contact in the connector
Checks
- 1Command the DEF pump temperature from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 2Wiggle the DEF pump temperature harness and connector while watching the live status in SerDia for dropouts
- 3Check both connector halves of the DEF pump temperature for loose, bent or fretted pins
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - DEF pump temperature - Data erratic intermittent or incorrect
Shared checks
Checks, in order
- 1Listen for the pump at the start of a dosing test and read its status in SerDia
- 2Measure the coil resistance of the pump motor and the metering valve
- 3Check the DEF lines and the suction filter for blockage and crystals
- 4Inspect the connectors for crystallised DEF and corrosion
Causes
- DEF pump failed, frozen or blocked by crystals
- Metering valve stuck or its coil open or shorted
- Suction line or filter in the tank blocked
- Connector corroded by DEF
Most common here: shorted low (4 of 22)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: A warning lamp or limited function.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.