Cummins · Aftertreatment
Cummins SCR exhaust temperature sensors fault codes
Thermistor-type exhaust temperature sensors sit at the SCR catalyst inlet, at its outlet and, on two-stage systems, between the two catalysts. The ECM uses them to decide when DEF dosing may start and to check that the catalyst is working.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 3142 to 8464 are all about the sCR exhaust temperature sensors. The most common failure type is erratic or implausible (12 of 27); 2 need an immediate stop. Start with this check: read the SCR inlet, outlet and intermediate temperatures live with the engine cold: all should match ambient.
How urgent are they?
2 of 27 codes here mean stop now; 23 can wait until the shift ends, but find the cause before the next one; 2 are information only.
- Stop now2
- Check soon23
- Info2
What should I check first?
Read the SCR inlet, outlet and intermediate temperatures live with the engine cold: all should match ambient
Shared checks27 of 27
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
SCR intake temperature sensor circuit2 codes
Cummins 3142SCR intake temperature sensor circuit: Voltage high / shorted high
Same failure as 3146 on the SCR intake temperature sensor circuit: the same fault condition as 3146, reported for this part. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Shorted highShorted highCheck soonCauses
- Same causes as 3146, applied to the SCR intake temperature sensor circuit
- Wiring or connector problem local to the SCR intake temperature sensor circuit
Checks
- 1Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
- 2Work through the checks listed for 3146, starting at the SCR intake temperature sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:SCR intake temperature sensor circuit - voltage high (shorted to a high source)
Cummins 3143SCR intake temperature sensor circuit: Voltage low / shorted low
Same failure as 3147 on the SCR intake temperature sensor circuit: the same fault condition as 3147, reported for this part. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Shorted lowShorted lowCheck soonCauses
- Same causes as 3147, applied to the SCR intake temperature sensor circuit
- Wiring or connector problem local to the SCR intake temperature sensor circuit
Checks
- 1Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
- 2Work through the checks listed for 3147, starting at the SCR intake temperature sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:SCR intake temperature sensor circuit - voltage low (shorted to a low source)
SCR intake temperature sensor3 codes
Cummins 3144SCR intake temperature sensor: Erratic reading
The ECM judges the SCR intake temperature sensor to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact on the SCR intake temperature sensor
- Part ageing or failing and giving unstable output
- Electrical noise from a poorly routed wire or a bad ground
Checks
- 1Watch the SCR intake temperature sensor live in INSITE and wiggle the harness and connector to catch dropouts
- 2Compare the SCR intake temperature sensor with a related reading to decide which one is wrong
- 3Check the connector for moisture and corrosion and the ground connection for tightness
- 4Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intake temperature sensor - data erratic or incorrect
Cummins 3145SCR intake temperature sensor: Abnormal rate of change
The SCR intake temperature sensor changed faster than it physically could, so the ECM treats the reading as a sensor or wiring problem and not as a real change. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the harness or connector of the SCR intake temperature sensor
- Failing part giving unstable output
- Poor ground or noisy supply feeding the circuit
Checks
- 1Log the SCR intake temperature sensor while moving the harness and connector, and look for steps instead of smooth changes
- 2Inspect the SCR intake temperature sensor connector for water, corrosion and loose pins
- 3Check the supply and ground at the SCR intake temperature sensor while the engine runs
- 4Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 6881SCR intake temperature sensor: Reading drifted high
The SCR intake temperature sensor reads higher than the ECM calculates it should, and it has crept upward over time. That is typical of a sensor that is ageing or contaminated. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensing element ageing and reading high
- Sensor contaminated by soot, oil or deposits
- Slow rise in resistance in a connector or wire
Checks
- 1Compare the SCR intake temperature sensor with a known good sensor or a reference gauge at the same operating point
- 2Clean or replace the SCR intake temperature sensor if it is contaminated, and check its sensing port for blockage
- 3Measure the voltage drop in the wiring to the SCR intake temperature sensor for extra resistance
- 4Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intake temperature sensor - data drifted high
SCR outlet temperature sensor5 codes
Cummins 3148SCR outlet temperature sensor: Erratic reading
Same failure as 3144 on the SCR outlet temperature sensor: the same fault condition as 3144, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 3144, applied to the SCR outlet temperature sensor
- Wiring or connector problem local to the SCR outlet temperature sensor
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3144, starting at the SCR outlet temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR outlet temperature sensor - data erratic or incorrect
Cummins 3149SCR outlet temperature sensor: Abnormal rate of change
Same failure as 3145 on the SCR outlet temperature sensor: the same fault condition as 3145, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 3145, applied to the SCR outlet temperature sensor
- Wiring or connector problem local to the SCR outlet temperature sensor
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3145, starting at the SCR outlet temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 6791SCR outlet temperature sensor: Reading drifted high
Same failure as 6881 on the SCR outlet temperature sensor: the same fault condition as 6881, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 6881, applied to the SCR outlet temperature sensor
- Wiring or connector problem local to the SCR outlet temperature sensor
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 6881, starting at the SCR outlet temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR outlet temperature sensor - data drifted high
Cummins 6792SCR outlet temperature sensor: Reading drifted low
Same failure as 8464 on the SCR outlet temperature sensor: the same fault condition as 8464, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 8464, applied to the SCR outlet temperature sensor
- Wiring or connector problem local to the SCR outlet temperature sensor
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 8464, starting at the SCR outlet temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR outlet temperature sensor - data drifted low
Cummins 6876SCR outlet temperature sensor: Reading drifted high
Same failure as 6881 on the SCR outlet temperature sensor: the same fault condition as 6881, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 6881, applied to the SCR outlet temperature sensor
- Wiring or connector problem local to the SCR outlet temperature sensor
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 6881, starting at the SCR outlet temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR outlet temperature sensor - data drifted high
SCR intake temperature4 codes
Cummins 3164SCR intake temperature: Above normal· least severe
Same failure as 3229 on the SCR intake temperature: the same fault condition as 3229, reported for this part. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Real conditionReal conditionInfoCauses
- Same causes as 3229, applied to the SCR intake temperature
- Wiring or connector problem local to the SCR intake temperature
Checks
- 1Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
- 2Work through the checks listed for 3229, starting at the SCR intake temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR intake temperature - above normal - least severe
Cummins 3229SCR intake temperature: Above normal· most severe
The SCR intake temperature is above its normal range (severity: most severe). The ECM sets the code from a real reading, so look for a genuine cause before blaming the sensor. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Real conditionReal conditionStop nowCauses
- A real over-limit condition in the system the SCR intake temperature measures
- Sensor or circuit reading high from a wiring fault
- A cooling, flow or restriction problem upstream that drives the value up
Checks
- 1Confirm the real condition with a gauge or a second reading before replacing the SCR intake temperature
- 2Check that the SCR intake temperature circuit codes are not active, since a wiring fault can fake a high reading
- 3Look for the physical cause upstream, such as restriction, leakage, poor cooling or heavy load
- 4Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR intake temperature - above normal - most severe
Cummins 3231SCR intake temperature: Above normal· moderately severe
Same failure as 3229 on the SCR intake temperature: the same fault condition as 3229, reported for this part. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Real conditionReal conditionCheck soonCauses
- Same causes as 3229, applied to the SCR intake temperature
- Wiring or connector problem local to the SCR intake temperature
Checks
- 1Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
- 2Work through the checks listed for 3229, starting at the SCR intake temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR intake temperature - above normal - moderately severe
Cummins 8464SCR intake temperature: Reading drifted low
The SCR intake temperature reads lower than the ECM calculates it should, and it has crept downward over time. That is typical of a sensor that is ageing or leaking. The SCR intake sensor sits at the catalyst inlet and tells the ECM when the exhaust is hot enough to start DEF dosing.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensing element ageing and reading low
- Sensor port blocked or leaking so it does not see the true value
- Slow rise in resistance in a connector or wire
Checks
- 1Compare the SCR intake temperature with a known good sensor or a reference gauge at the same operating point
- 2Inspect the SCR intake temperature sensing port and seals for blockage or leakage
- 3Measure the voltage drop in the wiring to the SCR intake temperature for extra resistance
- 4Compare it with the DPF outlet reading, which should be close when no heat is lost along the pipe.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intake temperature - data drifted low
SCR outlet temperature3 codes
Cummins 3165SCR outlet temperature: Above normal· most severe
Same failure as 3229 on the SCR outlet temperature: the same fault condition as 3229, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Real conditionReal conditionStop nowCauses
- Same causes as 3229, applied to the SCR outlet temperature
- Wiring or connector problem local to the SCR outlet temperature
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3229, starting at the SCR outlet temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR outlet temperature - above normal - most severe
Cummins 3235SCR outlet temperature: Above normal· moderately severe
Same failure as 3229 on the SCR outlet temperature: the same fault condition as 3229, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Real conditionReal conditionCheck soonCauses
- Same causes as 3229, applied to the SCR outlet temperature
- Wiring or connector problem local to the SCR outlet temperature
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3229, starting at the SCR outlet temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR outlet temperature - above normal - moderately severe
Cummins 3236SCR outlet temperature: Above normal· least severe
Same failure as 3229 on the SCR outlet temperature: the same fault condition as 3229, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Real conditionReal conditionInfoCauses
- Same causes as 3229, applied to the SCR outlet temperature
- Wiring or connector problem local to the SCR outlet temperature
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3229, starting at the SCR outlet temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR outlet temperature - above normal - least severe
SCR intermediate gas temperature sensor circuit2 codes
Cummins 4518SCR intermediate gas temperature sensor circuit: Voltage high / shorted high
Same failure as 3146 on the SCR intermediate gas temperature sensor circuit: the same fault condition as 3146, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Shorted highShorted highCheck soonCauses
- Same causes as 3146, applied to the SCR intermediate gas temperature sensor circuit
- Wiring or connector problem local to the SCR intermediate gas temperature sensor circuit
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3146, starting at the SCR intermediate gas temperature sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:SCR intermediate gas temperature sensor circuit - voltage high (shorted to a high source)
Cummins 4519SCR intermediate gas temperature sensor circuit: Voltage low / shorted low
Same failure as 3147 on the SCR intermediate gas temperature sensor circuit: the same fault condition as 3147, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Shorted lowShorted lowCheck soonCauses
- Same causes as 3147, applied to the SCR intermediate gas temperature sensor circuit
- Wiring or connector problem local to the SCR intermediate gas temperature sensor circuit
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3147, starting at the SCR intermediate gas temperature sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:SCR intermediate gas temperature sensor circuit - voltage low (shorted to a low source)
SCR intermediate gas temperature sensor3 codes
Cummins 4521SCR intermediate gas temperature sensor: Erratic reading
Same failure as 3144 on the SCR intermediate gas temperature sensor: the same fault condition as 3144, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 3144, applied to the SCR intermediate gas temperature sensor
- Wiring or connector problem local to the SCR intermediate gas temperature sensor
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3144, starting at the SCR intermediate gas temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intermediate gas temperature sensor - data erratic or incorrect
Cummins 6266SCR intermediate gas temperature sensor: Erratic reading
Same failure as 3144 on the SCR intermediate gas temperature sensor: the same fault condition as 3144, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 3144, applied to the SCR intermediate gas temperature sensor
- Wiring or connector problem local to the SCR intermediate gas temperature sensor
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3144, starting at the SCR intermediate gas temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intermediate gas temperature sensor - data erratic or incorrect
Cummins 6267SCR intermediate gas temperature sensor: Erratic reading
Same failure as 3144 on the SCR intermediate gas temperature sensor: the same fault condition as 3144, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 3144, applied to the SCR intermediate gas temperature sensor
- Wiring or connector problem local to the SCR intermediate gas temperature sensor
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3144, starting at the SCR intermediate gas temperature sensor and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:SCR intermediate gas temperature sensor - data erratic or incorrect
SCR intermediate gas temperature2 codes
Cummins 4524SCR intermediate gas temperature: Above normal· most severe
Same failure as 3229 on the SCR intermediate gas temperature: the same fault condition as 3229, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Real conditionReal conditionCheck soonCauses
- Same causes as 3229, applied to the SCR intermediate gas temperature
- Wiring or connector problem local to the SCR intermediate gas temperature
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3229, starting at the SCR intermediate gas temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR intermediate gas temperature - above normal - most severe
Cummins 4525SCR intermediate gas temperature: Above normal· moderately severe
Same failure as 3229 on the SCR intermediate gas temperature: the same fault condition as 3229, reported for this part. The intermediate sensor sits between the two catalysts on a two-stage SCR system.· Real conditionReal conditionCheck soonCauses
- Same causes as 3229, applied to the SCR intermediate gas temperature
- Wiring or connector problem local to the SCR intermediate gas temperature
Checks
- 1Compare it with both the SCR intake and the SCR outlet readings to see which one disagrees.
- 2Work through the checks listed for 3229, starting at the SCR intermediate gas temperature and its connector
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:SCR intermediate gas temperature - above normal - moderately severe
SCR outlet temperature sensor circuit1 code
Cummins 6268SCR outlet temperature sensor circuit: Voltage high / shorted high
Same failure as 3146 on the SCR outlet temperature sensor circuit: the same fault condition as 3146, reported for this part. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Shorted highShorted highCheck soonCauses
- Same causes as 3146, applied to the SCR outlet temperature sensor circuit
- Wiring or connector problem local to the SCR outlet temperature sensor circuit
Checks
- 1Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
- 2Work through the checks listed for 3146, starting at the SCR outlet temperature sensor circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:SCR outlet temperature sensor circuit - voltage high (shorted to a high source)
Other codes2 codes
Cummins 3146SCR outlet temperature sensor signal voltage high
The ECM reads the SCR outlet temperature sensor signal voltage high above its allowed voltage band. That points to a short to a 5 V or battery wire, a lost return, or a failed part, rather than a real change in what it measures. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Shorted highShorted highCheck soonCauses
- Short to a 5 V reference or a battery wire in the harness to the SCR outlet temperature sensor signal voltage high
- Open or high-resistance return wire that lets the signal float high
- Water or corrosion in the connector bridging two pins together
Checks
- 1Key on, unplug the SCR outlet temperature sensor signal voltage high and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
- 2Jumper the signal wire of the SCR outlet temperature sensor signal voltage high to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
- 3Check continuity and resistance of the return wire from the SCR outlet temperature sensor signal voltage high back to the ECM
- 4Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Cummins 3147SCR outlet temperature sensor signal voltage low
The ECM reads the SCR outlet temperature sensor signal voltage low below its allowed voltage band. That points to a short to ground, an open supply or signal wire, or a failed part, not necessarily a real low value. The SCR outlet sensor sits after the catalyst and shows whether the catalyst is doing its work.· Shorted lowShorted lowCheck soonCauses
- Signal wire to the SCR outlet temperature sensor signal voltage low rubbed through and shorted to ground or to the engine block
- Open 5 V reference or open signal wire that lets the input drop to zero
- Corroded or backed-out pin in the SCR outlet temperature sensor signal voltage low connector
Checks
- 1Key on, unplug the SCR outlet temperature sensor signal voltage low and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
- 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
- 3Measure resistance from the SCR outlet temperature sensor signal voltage low signal wire to ground with the ECM unplugged to find a short
- 4Compare it with the SCR intake reading while dosing: the outlet should follow with a small lag.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Read the SCR inlet, outlet and intermediate temperatures live with the engine cold: all should match ambient
- 2Unplug the suspect SCR sensor and measure its resistance at ambient, then compare it with a good sensor of the same type
- 3Inspect the harness near the DEF dosing point for crystals, heat damage and chafing
- 4Run the engine warm and compare the SCR inlet with the SCR outlet: the outlet should rise only when the catalyst is converting
- 5Check DEF dosing, DEF quality and catalyst codes before replacing a temperature sensor
Causes
- Harness or connector damaged near the SCR housing or the DEF dosing point
- Failed thermistor reading out of range or drifting
- DEF crystals or deposits near the sensor changing heat transfer
- Real over-temperature from a failed regeneration upstream
Most common here: erratic or implausible (12 of 27)
Watch the live value on the service tool while you flex the harness and tap the connector.
When to stop
You'll notice: DEF dosing that will not start or is limited, a lamp and possibly a derate; the engine runs normally otherwise.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
- Cummins ISX15 (2010-2012) Fault Code List (Diesel Repair)
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
- Cummins L9 (2016-2020) Fault Code List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
