EF Logo

Cummins · Aftertreatment

Cummins SCR catalyst performance and NH3 sensor fault codes

These codes come from the SCR monitors rather than a single sensor. An ammonia sensor in the SCR system detects ammonia slip, so the ECM does not overdose DEF.

FaultStop3151Cummins · SCR catalyst performance and NH3 sensor
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 3151 to 6771 are all about the sCR catalyst performance and NH3 sensor. The most common failure type is erratic or implausible (6 of 22); 1 needs an immediate stop. Start with this check: check the DEF quality and the dosing system first.

How urgent are they?

1 of 22 codes here means stop now; 14 can wait until the shift ends, but find the cause before the next one; 7 are information only.

  • Stop now1
  • Check soon14
  • Info7

What should I check first?

Check the DEF quality and the dosing system first

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • SCR catalyst system2 codes

    • Cummins 3751SCR catalyst system: Mechanical fault or not responding

      The ECM commands the SCR catalyst system but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the SCR catalyst system in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 4585SCR catalyst system: Special instructions

      The ECM sets a special-instruction fault for the SCR catalyst system.· Other
      Info

      Causes

      • A condition that requires a guided repair or verification step
      • A related fault that set first

      Checks

      1. 1Open the fault in INSITE and follow its troubleshooting steps
      2. 2Clear all related codes first and recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • SCR intermediate NH3 sensor5 codes

    • Cummins 3899SCR intermediate NH3 sensor: Voltage low / shorted low

      The ECM sees the SCR intermediate NH3 sensor signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live SCR intermediate NH3 sensor value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:SCR intermediate NH3 sensor - voltage low (shorted to a low source)

    • Cummins 3911SCR intermediate NH3 sensor: Abnormal update rate

      The ECM is not receiving fresh data for the SCR intermediate NH3 sensor at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3935SCR intermediate NH3 sensor: Out of calibration

      The ECM reports the SCR intermediate NH3 sensor as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controller
      Check soon

      Causes

      • Sensor or device out of tolerance
      • Wrong calibration or learn data after a repair

      Checks

      1. 1Check whether a learn or calibration procedure is needed after the last repair
      2. 2Compare with a related sensor and replace the part if the offset is real
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 3936SCR intermediate NH3 sensor: Bad device or component

      The ECM judges the SCR intermediate NH3 sensor to be an internal failure of the device or module.· Part or controller
      Check soon

      Causes

      • Internal failure of the device
      • Supply or ground problem causing it to reset
      • Corrupt software

      Checks

      1. 1Check supply and ground at the device before condemning it
      2. 2Reflash with the correct software where possible
      3. 3Replace the device if the fault persists after the supply tests are good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 3937SCR intermediate NH3 sensor: Abnormal rate of change

      The SCR intermediate NH3 sensor reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the SCR intermediate NH3 sensor reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Outlet NH3 sensor heater1 code

    • Cummins 3912Outlet NH3 sensor heater: Abnormal rate of change

      The outlet NH3 sensor heater reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the outlet NH3 sensor heater reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • SCR intermediate NH3 gas sensor power supply3 codes

    • Cummins 3932SCR intermediate NH3 gas sensor power supply: Above normal· moderately severe

      The SCR intermediate NH3 gas sensor power supply is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live SCR intermediate NH3 gas sensor power supply with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:SCR intermediate NH3 gas sensor power supply - above normal - moderately severe

    • Cummins 3933SCR intermediate NH3 gas sensor power supply: Below normal· moderately severe

      The SCR intermediate NH3 gas sensor power supply is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live SCR intermediate NH3 gas sensor power supply with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:SCR intermediate NH3 gas sensor power supply - below normal - moderately severe

    • Cummins 3934SCR intermediate NH3 gas sensor power supply: Erratic reading

      The ECM judges the SCR intermediate NH3 gas sensor power supply to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the SCR intermediate NH3 gas sensor power supply live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:SCR intermediate NH3 gas sensor power supply - data erratic or incorrect

  • SCR intermediate NH32 codes

    • Cummins 4279SCR intermediate NH3: Reading drifted low

      The SCR intermediate NH3 reading has drifted low compared with what the ECM expects from the other sensors and its model.· Erratic or implausible
      Check soon

      Causes

      • Sensor element contaminated or aged
      • Real condition such as an exhaust leak or restriction biasing the reading

      Checks

      1. 1Compare the SCR intermediate NH3 with the related sensors on a cold, soaked engine, where they should agree
      2. 2Replace the sensor only after the wiring and any leaks have been ruled out
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:SCR intermediate NH3 - data drifted low

    • Cummins 4281SCR intermediate NH3: Erratic reading

      The ECM judges the SCR intermediate NH3 to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the SCR intermediate NH3 live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:SCR intermediate NH3 - data erratic or incorrect

  • Intermediate NH3 sensor closed loop operation1 code

    • Cummins 4453Intermediate NH3 sensor closed loop operation: Condition exists

      The ECM sets this code when it recognises a defined condition for the intermediate NH3 sensor closed loop operation.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • SCR conversion efficiency1 code

    • Cummins 5655SCR conversion efficiency: Condition exists

      The ECM sets this code when it recognises a defined condition for the SCR conversion efficiency.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • SCR feedback control status1 code

    • Cummins 5868SCR feedback control status: Mechanical fault or not responding

      The ECM commands the SCR feedback control status but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the SCR feedback control status in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • SCR thermal management1 code

    • Cummins 6244SCR thermal management: Condition exists

      The ECM sets this code when it recognises a defined condition for the SCR thermal management.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • SCR monitoring system malfunction2 codes

    • Cummins 6613SCR monitoring system malfunction: Special instructions

      The ECM sets a special-instruction fault for the SCR monitoring system malfunction.· Other
      Info

      Causes

      • A condition that requires a guided repair or verification step
      • A related fault that set first

      Checks

      1. 1Open the fault in INSITE and follow its troubleshooting steps
      2. 2Clear all related codes first and recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6656SCR monitoring system malfunction: Condition exists

      The ECM sets this code when it recognises a defined condition for the SCR monitoring system malfunction.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Aftertreatment system assembly1 code

    • Cummins 6771Aftertreatment system assembly: Special instructions

      The ECM sets a special-instruction fault for the aftertreatment system assembly.· Other
      Info

      Causes

      • A condition that requires a guided repair or verification step
      • A related fault that set first

      Checks

      1. 1Open the fault in INSITE and follow its troubleshooting steps
      2. 2Clear all related codes first and recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Other codes2 codes

    • Cummins 3151SCR catalyst missing

      The ECM thinks the SCR catalyst is not in the exhaust, which can mean it was removed, or that the temperature and NOx readings do not match a working catalyst.· Lost message
      Stop now

      Causes

      • Catalyst removed or destroyed
      • NOx or temperature sensors giving implausible values
      • Exhaust piping modified

      Checks

      1. 1Look at the exhaust components to confirm the catalyst is fitted
      2. 2Check the NOx and temperature sensor readings
      3. 3Check for related NOx sensor and SCR codes in INSITE that explain why the ECM judged the catalyst missing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Cummins 3582SCR catalyst conversion efficiency low

      The SCR catalyst is not reducing enough NOx.· Lost message
      Check soon

      Causes

      • Poor quality DEF
      • Dosing unit blocked or under-dosing
      • Catalyst worn out or contaminated

      Checks

      1. 1Check the DEF level and quality first, because poor DEF is the most common cause
      2. 2Check for other SCR, NOx sensor and dosing codes in INSITE before judging the catalyst
      3. 3Run the DEF dosing test to see that dosing delivers the correct quantity
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Check the DEF quality and the dosing system first
  2. 2Check the sensor connector and wiring for damage and corrosion
  3. 3Verify the NOx sensors read plausible values compared with each other
  4. 4Inspect the exhaust for leaks upstream of the NOx sensors
  5. 5Check for DEF over-dosing or dosing unit faults
  6. 6Check the SCR catalyst is fitted and is the correct part
  7. 7Check the DEF quality and the dosing rate in INSITE

Causes

  • Poor DEF quality or dosing problem
  • Sensor drifted or failed
  • Catalyst aged, damaged or missing
  • Wiring or connector fault

Most common here: erratic or implausible (6 of 22)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: An emissions lamp, and if not repaired the SCR inducement strategy will derate the engine.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.