EF Logo

Cummins · Aftertreatment

Cummins DEF tank level, temperature, status and tank heater fault codes

The DEF tank holds the level and temperature sensors. The level sensor tells the ECM how much DEF is left so it can warn the driver and start inducement if the tank runs dry, and the temperature sensor tells it whether the fluid is frozen and whether the tank heater should run.

More about these parts

Two status codes report an empty tank and a frozen dosing system. The DEF tank has a heater, usually using engine coolant through a valve, that thaws frozen fluid in cold weather.

FaultCheck1668Cummins · DEF tank level sensor circuit
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 1668 to 7896 are all about the dEF tank level, temperature, status and tank heater. The most common failure type is erratic or implausible (4 of 25); 1 needs an immediate stop. Start with this check: check the actual DEF level and top up with the correct fluid before trusting any reading.

How urgent are they?

1 of 25 codes here means stop now; 20 can wait until the shift ends, but find the cause before the next one; 4 are information only.

  • Stop now1
  • Check soon20
  • Info4

What should I check first?

Check the actual DEF level and top up with the correct fluid before trusting any reading

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF tank level sensor circuit2 codes

    • Cummins 1668DEF tank level sensor circuit: Voltage low / shorted low

      The ECM sees the DEF tank level sensor signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live DEF tank level sensor circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DEF tank level sensor circuit - voltage low (shorted to a low source)

    • Cummins 1669DEF tank level sensor circuit: Voltage high / shorted high

      The ECM sees the DEF tank level sensor signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live DEF tank level sensor circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF tank level sensor circuit - voltage high (shorted to a high source)

  • DEF tank temperature sensor3 codes

    • Cummins 1677DEF tank temperature sensor: Voltage low / shorted low

      The ECM sees the DEF tank temperature sensor signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live DEF tank temperature sensor value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:DEF tank temperature sensor - voltage low (shorted to a low source)

    • Cummins 1678DEF tank temperature sensor: Voltage high / shorted high

      The ECM sees the DEF tank temperature sensor signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live DEF tank temperature sensor value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:DEF tank temperature sensor - voltage high (shorted to a high source)

    • Cummins 4731DEF tank temperature sensor: Out of calibration

      The ECM reports the DEF tank temperature sensor as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controller
      Check soon

      Causes

      • Sensor or device out of tolerance
      • Wrong calibration or learn data after a repair

      Checks

      1. 1Check whether a learn or calibration procedure is needed after the last repair
      2. 2Compare with a related sensor and replace the part if the offset is real
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • DEF tank temperature4 codes

    • Cummins 1679DEF tank temperature: Erratic reading

      The ECM judges the DEF tank temperature to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DEF tank temperature live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DEF tank temperature - data erratic or incorrect

    • Cummins 3651DEF tank temperature: Below normal· moderately severe

      The DEF tank temperature is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF tank temperature with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF tank temperature - below normal - moderately severe

    • Cummins 4572DEF tank temperature: Abnormal update rate

      The ECM is not receiving fresh data for the DEF tank temperature at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4737DEF tank temperature: Root cause not known

      The ECM detects a problem with the DEF tank temperature but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DEF tank heater circuit1 code

    • Cummins 1683DEF tank heater circuit: Voltage high

      The ECM sees the tank heater valve output high, which suggests a short to supply or an open return in that circuit.· Shorted high
      Check soon

      Causes

      • Heater valve wire shorted to supply
      • Open return on the heater valve
      • Valve stuck open

      Checks

      1. 1Check whether the DEF tank is warm to the touch with the engine cold
      2. 2Measure the driver pin at the unplugged connector with the key on
      3. 3Check the return wire for continuity from the connector back to the ECM pin
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • DEF tank heater4 codes

    • Cummins 1712DEF tank heater: Below normal· moderately severe

      The DEF tank heater is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF tank heater with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF tank heater - below normal - moderately severe

    • Cummins 1713DEF tank heater: Above normal· moderately severe

      The DEF tank heater is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF tank heater with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF tank heater - above normal - moderately severe

    • Cummins 3242DEF tank heater: Mechanical fault or not responding

      The ECM commands the DEF tank heater but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the DEF tank heater in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 3576DEF tank heater: Current low / open circuit

      The ECM commands the DEF tank heater but sees little or no current flow.· Open circuit
      Check soon

      Causes

      • Open wire or a terminal pushed back in the connector
      • Open winding in the component
      • Blown fuse or failed relay feeding the circuit

      Checks

      1. 1Check continuity from the ECM pin to the DEF tank heater connector, wiggling the harness as you test
      2. 2Measure the component resistance with the connector unplugged; an open reading means the part has failed
      3. 3Check the fuse and relay feeding the circuit
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:DEF tank heater - current low or open circuit

  • DEF tank level2 codes

    • Cummins 4677DEF tank level: Abnormal update rate

      The ECM is not receiving fresh data for the DEF tank level at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 7896DEF tank level: Condition exists

      The ECM sets this code when it recognises a defined condition for the DEF tank level.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DEF tank level sensor3 codes

    • Cummins 4732DEF tank level sensor: Out of calibration

      The ECM reports the DEF tank level sensor as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controller
      Check soon

      Causes

      • Sensor or device out of tolerance
      • Wrong calibration or learn data after a repair

      Checks

      1. 1Check whether a learn or calibration procedure is needed after the last repair
      2. 2Compare with a related sensor and replace the part if the offset is real
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 4739DEF tank level sensor: Root cause not known

      The ECM detects a problem with the DEF tank level sensor but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 4769DEF tank level sensor: Abnormal rate of change

      The DEF tank level sensor reading is changing faster than the real quantity could move.· Erratic or implausible
      Check soon

      Causes

      • Loose or corroded connector causing intermittent contact
      • Intermittent wiring fault that opens and closes
      • Sensor starting to fail

      Checks

      1. 1Watch the DEF tank level sensor reading live and wiggle the harness and connector to see whether it jumps
      2. 2Inspect the connector pins for corrosion and spread terminals
      3. 3Compare with a related sensor to see whether the jump is real
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Other codes6 codes

    • Cummins 1673DEF tank level very low· most severe

      The DEF tank level is below the lowest limit, so the SCR system is about to run out of fluid.· Other
      Check soon

      Causes

      • DEF tank genuinely almost empty
      • DEF level sensor in the tank header reading low
      • DEF added but the sensor has not seen it because of a fouled float or header
      • Dash gauge not matching the level sensor value

      Checks

      1. 1Look at the DEF tank level and top up with fresh DEF to the full mark
      2. 2Read the DEF tank level value in INSITE and compare it with the real fluid level
      3. 3Inspect the tank header and level sensor for crystals and damage
      4. 4Clear the fault after refill and run the engine to see that the level updates
      5. 5Check the level sensor circuit if the tank is full but the reading stays low
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DEF tank level very low - most severe

    • Cummins 1684DEF tank heater circuit shorted low or driver voltage low

      The ECM drives the DEF tank heater circuit but sees its output pulled to ground.· Shorted low
      Check soon

      Causes

      • Tank heater circuit shorted to ground
      • Heater valve coil shorted
      • Connector wet at the tank

      Checks

      1. 1In cold weather check whether the tank heater warms the DEF
      2. 2Unplug the heater connector and see whether the code changes
      3. 3Measure the tank heater valve coil resistance at the connector against the service value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 3497DEF tank level low· least severe

      The DEF level is down to the first warning point.· Other
      Info

      Causes

      • DEF tank getting low in normal use
      • DEF level sensor under-reading
      • Tank not topped up at the last fuel stop

      Checks

      1. 1Add DEF to the correct level and watch the dash message clear
      2. 2Compare the INSITE DEF level with the tank sight level
      3. 3Check the level sensor and header for crystals if the reading is off
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DEF tank level low - least severe

    • Cummins 3498DEF tank level low· moderately severe

      The DEF level is below the second warning point.· Other
      Check soon

      Causes

      • DEF tank low from normal use
      • DEF level sensor reading too low
      • Large leak in the DEF line or tank

      Checks

      1. 1Fill the DEF tank and confirm the dash level rises
      2. 2Look for DEF leaks under the machine and at the dosing unit
      3. 3Read the DEF level in INSITE and compare with the tank
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:DEF tank level low - moderately severe

    • Cummins 3547DEF tank empty

      The ECM has recognised that the DEF tank is empty.· Other
      Stop now

      Causes

      • DEF tank run completely dry
      • Level sensor reading empty while there is DEF
      • DEF line leak draining the tank
      • Dash message left active after refilling

      Checks

      1. 1Fill the tank with fresh DEF and confirm the level in INSITE
      2. 2Check for DEF leaks around the pump, lines and the dosing unit
      3. 3Clear the fault and run the DEF dosing test to confirm that the pump builds pressure with the new fluid
      4. 4Verify that the level sensor reads the new level
      5. 5Confirm the inducement clears after the repair
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 5278DEF dosing system frozen

      The ECM reports that the DEF dosing system is frozen.· Real condition
      Check soon

      Causes

      • DEF lines or pump frozen in cold weather
      • DEF line heaters not working
      • Tank heater coolant valve stuck closed

      Checks

      1. 1Move the machine to a warm place or let it warm up
      2. 2Check that the line heaters warm up when the key is on
      3. 3Check the tank heater and the coolant valve that feeds it, which should open in cold weather
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check the actual DEF level and top up with the correct fluid before trusting any reading
  2. 2Check the heater valve and its wiring for shorts and opens
  3. 3Read the level and temperature values live and compare them with the real tank contents
  4. 4Inspect the tank module connector and harness for corrosion and damage
  5. 5Measure the heater circuit resistance at the connector
  6. 6Check the tank heater, coolant valve and DEF line heaters in cold weather
  7. 7Measure the temperature sensor resistance at ambient and compare it with a known good sensor

Causes

  • Sensor connector or harness damaged, corroded or loose in the tank module
  • Heater valve or coolant supply fault
  • Failed level or temperature sensor, or a contaminated sensor head
  • Wiring or connector fault

Most common here: erratic or implausible (4 of 25)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: DEF level warnings that do not match the real level, a DEF lamp, and a derate or speed limit if the tank is empty or the ECM cannot read it.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.