Cummins DEF quality and DEF pressure fault codes

A sensor measures the quality or concentration of the DEF. A pressure sensor on the DEF supply line tells the ECM whether the pump is building the correct pressure for dosing.

FaultCheck3596Cummins · DEF quality and DEF pressure
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 1685 to 6767 are all about the dEF quality and DEF pressure. The most common failure type is real condition (9 of 23); none needs an immediate stop. Start with this check: check the DEF with a refractometer for the correct concentration.

How urgent are they?

None of the 23 codes here means stop now; 17 can wait until the shift ends, but find the cause before the next one; 6 are information only.

  • Check soon17
  • Info6

What should I check first?

Check the DEF with a refractometer for the correct concentration

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF quality sensor circuit2 codes

    • Cummins 1685DEF quality sensor circuit: Voltage low

      The ECM sees the DEF quality sensor circuit pulled low, which usually means a short to ground, a missing supply or a failed sensor.· Shorted low
      Check soon

      Causes

      • Sensor harness shorted to ground
      • Sensor supply open or connector corroded
      • Quality sensor failed

      Checks

      1. 1Check the sensor connector at the DEF tank header for moisture and crystals
      2. 2Measure the supply voltage at the unplugged connector with the key on
      3. 3Test the signal wire for a short to ground with the key off
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 1686DEF quality sensor circuit: Voltage high

      The ECM sees the DEF quality sensor circuit pulled high, which indicates a short to power or an open return wire.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to a supply
      • Open return wire on the sensor
      • Quality sensor failed

      Checks

      1. 1Check the connector for moisture and corrosion
      2. 2Measure the return wire continuity to the ECM
      3. 3Check the signal wire for a short to a supply wire with the sensor unplugged
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • DEF quality6 codes

    • Cummins 1715DEF quality: Root cause not known

      The ECM detects a problem with the DEF quality but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 3866DEF quality: Below normal· most severe

      The DEF quality is below its normal operating range and the ECM rates it as most severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF quality with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF quality - below normal - most severe

    • Cummins 3868DEF quality: Abnormal update rate

      The ECM is not receiving fresh data for the DEF quality at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3878DEF quality: Erratic reading

      The ECM judges the DEF quality to be erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact
      • Sensor ageing or failing
      • A real fluctuation in the system it measures

      Checks

      1. 1Watch the DEF quality live and wiggle the harness and connector to catch dropouts
      2. 2Compare it with a related sensor to see which one is wrong
      3. 3Check the connector for moisture and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:DEF quality - data erratic or incorrect

    • Cummins 4277DEF quality: Abnormal update rate

      The ECM is not receiving fresh data for the DEF quality at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 4842DEF quality: Above normal· least severe

      The DEF quality is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF quality with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF quality - above normal - least severe

  • NOx limit exceeded1 code

    • Cummins 3543NOx limit exceeded: Insufficient DEF quality

      The ECM sees NOx above the limit because the DEF quality is not good enough to reduce NOx.· Shorted high
      Check soon

      Causes

      • Diluted DEF (water) or wrong fluid in the tank
      • Old DEF that has degraded in heat
      • DEF quality sensor fault or dirty sensor
      • Dosing unit blocked and giving too little DEF

      Checks

      1. 1Test the DEF with a refractometer for concentration
      2. 2Drain and flush the DEF tank if the DEF fails the test, then refill with fresh DEF
      3. 3Check the DEF quality sensor reading in INSITE
      4. 4Run the dosing test to see that DEF is actually injected
      5. 5After the repair, clear the inducement with INSITE and test drive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • DEF pressure3 codes

    • Cummins 3575DEF pressure: Above normal· moderately severe

      The DEF pressure is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF pressure - above normal - moderately severe

    • Cummins 5935DEF pressure: Mechanical fault or not responding

      The ECM commands the DEF pressure but it does not respond as expected, or its movement is out of adjustment.· Part or controller
      Check soon

      Causes

      • Mechanism seized, sooted or blocked
      • Wear or incorrect adjustment of the linkage or part
      • Supply or return fault limiting its movement

      Checks

      1. 1Command the DEF pressure in INSITE and watch whether it moves and returns
      2. 2Inspect the part and its linkage for sticking, debris or wear
      3. 3Check supply and return connections before replacing it
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 5936DEF pressure: Above normal· least severe

      The DEF pressure is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF pressure with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF pressure - above normal - least severe

  • DEF property4 codes

    • Cummins 4768DEF property: Root cause not known

      The ECM detects a problem with the DEF property but cannot tie it to one specific cause.· Other
      Info

      Causes

      • A related fault that set first
      • An intermittent connection or supply problem

      Checks

      1. 1Read all active and inactive codes and work the others first
      2. 2Check the supply, ground and connectors of the circuit involved
      3. 3Read the freeze-frame data for the conditions when it set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6765DEF property: Above normal· moderately severe

      The DEF property is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF property with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF property - above normal - moderately severe

    • Cummins 6766DEF property: Below normal· moderately severe

      The DEF property is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live DEF property with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF property - below normal - moderately severe

    • Cummins 6767DEF property: Condition exists

      The ECM sets this code when it recognises a defined condition for the DEF property.· Other
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • NOx limits exceeded due to insufficient reagent quality1 code

    • Cummins 6245NOx limits exceeded due to insufficient reagent quality: Condition exists

      The ECM sets this code when it recognises a defined condition for the NOx limits exceeded due to insufficient reagent quality.· Real condition
      Info

      Causes

      • A monitor or protection condition that has been met
      • A related fault that set first

      Checks

      1. 1Read the code description and freeze-frame in INSITE for the exact condition
      2. 2Work the related active codes first, then recheck
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Other codes6 codes

    • Cummins 1714DEF quality out of calibration

      The DEF quality sensor reading is out of its allowed calibration range, so the ECM cannot trust the concentration reading.· Part or controller
      Check soon

      Causes

      • Contaminated or diluted DEF
      • DEF quality sensor needs replacing or has drifted
      • Air or crystals around the sensor
      • Software calibration mismatch after a repair

      Checks

      1. 1Test a sample of the DEF with a refractometer for the correct concentration
      2. 2Replace the DEF if it fails the test and flush the tank
      3. 3Inspect the sensor in the tank header for crystals
      4. 4Check INSITE for a calibration update that corrects the quality sensor threshold
      5. 5Clear the fault and run the DEF system test to confirm the sensor now reads correctly
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 3571DEF pressure sensor signal voltage high

      The ECM sees the DEF pressure sensor signal above its normal voltage band.· Shorted high
      Check soon

      Causes

      • DEF pressure sensor signal shorted to supply in the pump harness
      • Return wire open at the pump connector
      • Pressure sensor in the pump head failed high

      Checks

      1. 1Read the DEF pressure with the key on and the pump idle; a high reading with no pump running confirms a sensor circuit fault
      2. 2Unplug the pump connector and measure supply and return at the harness
      3. 3Probe the signal wire for a short to a supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 3572DEF pressure sensor signal voltage low

      The ECM sees the DEF pressure sensor signal below its normal voltage band.· Shorted low
      Check soon

      Causes

      • DEF pressure sensor signal shorted to ground in the pump harness
      • Reference wire open at the pump connector
      • Sensor in the pump head failed low

      Checks

      1. 1Read the DEF pressure with the key on; a value stuck near zero while the pump runs points to the sensor circuit
      2. 2Measure the 5 V reference at the unplugged pump connector
      3. 3Ohm the pressure signal wire to ground with the ECM plug removed to find a short in the harness
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • Cummins 3574DEF pressure too low· moderately severe

      The DEF line pressure is below the target.· Real condition
      Check soon

      Causes

      • DEF pump weak or its filter plugged
      • Air in the DEF lines
      • DEF leak in a line or the dosing unit

      Checks

      1. 1Check the DEF level and look for leaks at the pump and the dosing unit lines
      2. 2Replace the DEF filter and re-prime the system
      3. 3Run the dosing test and watch the pressure curve
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF pressure too low - moderately severe

    • Cummins 3596DEF pressure sensor data erratic or implausible

      The ECM does not trust the DEF pressure sensor reading because it drifts, jumps or disagrees with other sensors.· Erratic or implausible
      Check soon

      Causes

      • DEF pump head pressure sensor drifting inside the pump
      • Air in the DEF line giving erratic pressure
      • Dosing nozzle partly blocked by crystals making pressure swing
      • DEF filter restricted

      Checks

      1. 1Run the DEF system test and watch the pressure curve for swings
      2. 2Replace the DEF filter and re-prime the system
      3. 3Inspect the dosing nozzle for crystals that make the pressure surge as it clears and re-blocks
      4. 4Check the pump connector for moisture or crystals that give an intermittent pressure signal
      5. 5Replace the pump if the pressure is still unstable
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3867DEF quality below normal· moderately severe

      The DEF concentration is below the expected value, which usually means the DEF is diluted with water or the wrong fluid is in the tank.· Real condition
      Check soon

      Causes

      • DEF diluted by water
      • Wrong liquid added to the tank
      • DEF quality sensor reading low

      Checks

      1. 1Test the DEF with a refractometer and compare the concentration with the expected value
      2. 2Drain, flush and refill the DEF tank if the concentration is wrong
      3. 3Check the tank header and the quality sensor for crystals and a loose connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:DEF quality below normal - moderately severe

Shared checks

Checks, in order

  1. 1Check the DEF with a refractometer for the correct concentration
  2. 2Check the DEF filter and lines for blockage and crystals
  3. 3Drain and refill with fresh DEF if the fluid is off-spec
  4. 4Prime the system and watch the DEF pressure in INSITE
  5. 5Inspect the quality sensor connector and wiring
  6. 6Check the pressure sensor wiring and connector
  7. 7Check the DEF pump operation and listen for it

Causes

  • Diluted or contaminated DEF
  • Blocked DEF filter or line
  • Wrong fluid used
  • DEF pump failing

Most common here: real condition (9 of 23)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: An emissions lamp and, if the DEF is out of specification, a derate through SCR inducement.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.