Cummins · Aftertreatment
Cummins Aftertreatment fuel doser, pressure sensor and valves fault codes
On engines with an aftertreatment fuel doser, a pressure sensor measures the fuel supplied to the doser. A solenoid valve shuts off fuel to the aftertreatment doser.
More about these partsLess
The aftertreatment fuel doser injects diesel into the exhaust upstream of the DOC to raise exhaust temperature for regeneration. A purge air actuator clears the doser of fuel after regeneration.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 1923 to 4568 are all about the aftertreatment fuel doser, pressure sensor and valves. The most common failure type is real condition (4 of 17); none needs an immediate stop. Start with this check: compare the sensor reading with a known value at key on, engine off.
How urgent are they?
None of the 17 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Check soon16
- Info1
What should I check first?
Compare the sensor reading with a known value at key on, engine off
Shared checks17 of 17
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Aftertreatment fuel shutoff valve3 codes
Cummins 1923Aftertreatment fuel shutoff valve: Voltage high
The ECM sees the aftertreatment fuel shutoff valve output high, as with a short to supply or an open return on the valve.· Shorted highShorted highCheck soonCauses
- Shutoff valve driver wire shorted to a supply wire
- Open return on the valve
- Valve coil failed
Checks
- 1Command the valve in INSITE and listen for it to click
- 2Measure the driver pin at the unplugged connector with the key on
- 3Check the valve coil resistance against the service value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Cummins 1924Aftertreatment fuel shutoff valve: Voltage low
The ECM sees the aftertreatment fuel shutoff valve output low, as with a short to ground or a lost supply on the valve.· Shorted lowShorted lowCheck soonCauses
- Valve driver wire shorted to ground
- Valve coil shorted
- Supply fuse or feed to the valve open
Checks
- 1Command the valve in INSITE and see whether the fault follows the command
- 2Unplug the valve; a change to an open-circuit code means the coil was shorted
- 3Ohm the driver wire to ground with the ECM plug removed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Cummins 4568Aftertreatment fuel shutoff valve: Above normal· moderately severe
The aftertreatment fuel shutoff valve is above its normal operating range and the ECM rates it as moderately severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionCheck soonCauses
- The monitored condition really is too high because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live aftertreatment fuel shutoff valve with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Aftertreatment fuel shutoff valve - above normal - moderately severe
Aftertreatment fuel shutoff valve 12 codes
Cummins 1925Aftertreatment fuel shutoff valve 1: Erratic reading
The ECM judges the aftertreatment fuel shutoff valve 1 to be erratic, intermittent or implausible. The value jumps, drifts or disagrees with a related reading, which suggests a poor connection or a failing sensor.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact
- Sensor ageing or failing
- A real fluctuation in the system it measures
Checks
- 1Watch the aftertreatment fuel shutoff valve 1 live and wiggle the harness and connector to catch dropouts
- 2Compare it with a related sensor to see which one is wrong
- 3Check the connector for moisture and corrosion
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Aftertreatment fuel shutoff valve 1 - data erratic or incorrect
Cummins 1963Aftertreatment fuel shutoff valve 1: Mechanical fault or not responding
The ECM commands the aftertreatment fuel shutoff valve 1 but it does not respond as expected, or its movement is out of adjustment. The electrical circuit may test fine while the mechanical part is stuck or worn.· Part or controllerPart or controllerCheck soonCauses
- Mechanism seized, sooted or blocked
- Wear or incorrect adjustment of the linkage or part
- Supply or return fault limiting its movement
Checks
- 1Command the aftertreatment fuel shutoff valve 1 in INSITE and watch whether it moves and returns
- 2Inspect the part and its linkage for sticking, debris or wear
- 3Check supply and return connections before replacing it
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Aftertreatment fuel pressure sensor2 codes
Cummins 1926Aftertreatment fuel pressure sensor: Erratic reading
The ECM judges the aftertreatment fuel pressure sensor to be erratic, intermittent or implausible. The value jumps, drifts or disagrees with a related reading, which suggests a poor connection or a failing sensor.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact
- Sensor ageing or failing
- A real fluctuation in the system it measures
Checks
- 1Watch the aftertreatment fuel pressure sensor live and wiggle the harness and connector to catch dropouts
- 2Compare it with a related sensor to see which one is wrong
- 3Check the connector for moisture and corrosion
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Aftertreatment fuel pressure sensor - data erratic or incorrect
Cummins 2881Aftertreatment fuel pressure sensor: Below normal· least severe
The aftertreatment fuel pressure sensor is below its normal operating range and the ECM rates it as least severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionInfoCauses
- The monitored condition really is too low because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live aftertreatment fuel pressure sensor with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Aftertreatment fuel pressure sensor - below normal - least severe
Aftertreatment fuel pressure sensor circuit2 codes
Cummins 1927Aftertreatment fuel pressure sensor circuit: Voltage high / shorted high
The ECM sees the aftertreatment fuel pressure sensor signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live aftertreatment fuel pressure sensor circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Aftertreatment fuel pressure sensor circuit - voltage high (shorted to a high source)
Cummins 1928Aftertreatment fuel pressure sensor circuit: Voltage low / shorted low
The ECM sees the aftertreatment fuel pressure sensor signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live aftertreatment fuel pressure sensor circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Aftertreatment fuel pressure sensor circuit - voltage low (shorted to a low source)
Aftertreatment doser3 codes
Cummins 1932Aftertreatment doser: Erratic reading
The ECM judges the aftertreatment doser to be erratic, intermittent or implausible. The value jumps, drifts or disagrees with a related reading, which suggests a poor connection or a failing sensor.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact
- Sensor ageing or failing
- A real fluctuation in the system it measures
Checks
- 1Watch the aftertreatment doser live and wiggle the harness and connector to catch dropouts
- 2Compare it with a related sensor to see which one is wrong
- 3Check the connector for moisture and corrosion
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Aftertreatment doser - data erratic or incorrect
Cummins 1964Aftertreatment doser: Mechanical fault or not responding
The ECM commands the aftertreatment doser but it does not respond as expected, or its movement is out of adjustment. The electrical circuit may test fine while the mechanical part is stuck or worn.· Part or controllerPart or controllerCheck soonCauses
- Mechanism seized, sooted or blocked
- Wear or incorrect adjustment of the linkage or part
- Supply or return fault limiting its movement
Checks
- 1Command the aftertreatment doser in INSITE and watch whether it moves and returns
- 2Inspect the part and its linkage for sticking, debris or wear
- 3Check supply and return connections before replacing it
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 3167Aftertreatment doser: Below normal· moderately severe
The aftertreatment doser is below its normal operating range and the ECM rates it as moderately severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionCheck soonCauses
- The monitored condition really is too low because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live aftertreatment doser with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Aftertreatment doser - below normal - moderately severe
Aftertreatment fuel rate1 code
Cummins 2778Aftertreatment fuel rate: Above normal· moderately severe
The aftertreatment fuel rate is above its normal operating range and the ECM rates it as moderately severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionCheck soonCauses
- The monitored condition really is too high because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live aftertreatment fuel rate with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Aftertreatment fuel rate - above normal - moderately severe
Aftertreatment purge air actuator circuit2 codes
Cummins 3223Aftertreatment purge air actuator circuit: Voltage low / shorted low
The ECM sees the aftertreatment purge air actuator circuit drive circuit with voltage below the expected level. That usually means the output wire is shorted to ground or the component is pulling the line down.· Shorted lowShorted lowCheck soonCauses
- Output wire shorted to ground or chafed through to the chassis
- Component winding shorted internally
- Connector corroded and bridging the pins
Checks
- 1Unplug the aftertreatment purge air actuator circuit connector and measure the output pin to ground; a short here means the harness is at fault
- 2Measure the component resistance across its pins; a very low reading means a shorted winding
- 3Inspect the connector for moisture and bridged terminals
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Aftertreatment purge air actuator circuit - voltage low (shorted to a low source)
Cummins 3224Aftertreatment purge air actuator circuit: Voltage high / shorted high
The ECM sees the aftertreatment purge air actuator circuit drive circuit with voltage above the expected level. That usually means the output wire is shorted to a power feed, or the return path of the load is open.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery or a switched power feed
- Open ground or return path on the component
- Component winding failed or its connector damaged
Checks
- 1Unplug the aftertreatment purge air actuator circuit connector, key on, and measure the output pin to ground; battery voltage with nothing connected points to a short to power
- 2Inspect the harness for a rubbed wire or damaged splice touching a power feed
- 3Measure the component resistance across its pins to rule out an open winding
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Aftertreatment purge air actuator circuit - voltage high (shorted to a high source)
Aftertreatment purge air actuator1 code
Cummins 3225Aftertreatment purge air actuator: Mechanical fault or not responding
The ECM commands the aftertreatment purge air actuator but it does not respond as expected, or its movement is out of adjustment. The electrical circuit may test fine while the mechanical part is stuck or worn.· Part or controllerPart or controllerCheck soonCauses
- Mechanism seized, sooted or blocked
- Wear or incorrect adjustment of the linkage or part
- Supply or return fault limiting its movement
Checks
- 1Command the aftertreatment purge air actuator in INSITE and watch whether it moves and returns
- 2Inspect the part and its linkage for sticking, debris or wear
- 3Check supply and return connections before replacing it
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Other codes1 code
Cummins 1977Aftertreatment fuel doser circuit open circuit
The ECM finds no current flowing in the aftertreatment fuel doser circuit when it commands it on, so the circuit is open or the load is unplugged. It meters fuel into the exhaust for a regeneration.· Open circuitOpen circuitCheck soonCauses
- Aftertreatment fuel doser solenoid burnt open from exhaust heat
- Fuel line connector at the doser unplugged during a DPF service
- Wire to the doser broken where it is clipped to the exhaust bracket
Checks
- 1Command the aftertreatment doser in INSITE and listen for the valve to tick as it opens
- 2Measure the doser solenoid resistance at its connector and compare it with the service value
- 3Test both doser wires for continuity back to the ECM with the key off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Shared checks
Checks, in order
- 1Compare the sensor reading with a known value at key on, engine off
- 2Measure the valve coil resistance and compare it with the service manual
- 3Measure the doser circuit resistance with the connector unplugged
- 4Measure the purge actuator resistance with the connector unplugged
- 5Check the supply fuel pressure at the doser with a gauge
- 6Check the wiring for shorts to ground and battery and for open circuits
- 7Inspect the doser nozzle for coking if it is accessible
Causes
- Sensor or harness fault
- Valve coil open or shorted
- Doser nozzle clogged or coked
- Actuator coil open or shorted
Most common here: real condition (4 of 17)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: Regeneration may be disabled, so the DPF loads with soot and the engine may derate.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
- Cummins ISX15 (2010-2012) Fault Code List (Diesel Repair)
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.